• Title/Summary/Keyword: intraoral

Search Result 896, Processing Time 0.021 seconds

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

Usage of digital technique to facilitate communication between dentist, dental lab technician, and patients in diagnosis and restoration for maxillary anterior implant: a case report (디지털 기법을 활용한 치과의사, 기공사, 그리고 환자 간의 효과적인 소통을 통한 전치부 임플란트의 진단 및 심미수복 증례)

  • Bang, Haemin;Jang, Woohyung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.42-51
    • /
    • 2022
  • Esthetic restoration of maxillary anterior implant heavily depends on the direction of installation of implant fixture. In patients with malpositioned implant, it is crucial to communicate the limitations of prosthetic outcome with the patient before starting on a restoration. To facilitate the communication, three-dimensional virtual representation by superimposing facial and intraoral digital scans with Computed Tomography (CT, dicom file) was used for visualization of the limitations of prosthesis. Through digital diagnostic wax-up, the profile of right maxillary anterior incisor implant was expected to be protrusive, which the patient was not satisfied with. Since the patient already had done root canal treatment on left maxillary anterior incisor due to previous trauma, a new prosthetic design including both right and left maxillary anterior incisors was presented to the patient. The second design was chosen and his comments were delivered to dental lab. The patient was satisfied with the new prosthesis, aesthetically and functionally.

Fabrication of complete denture using CAD-based vertical dimension increase and monolithic disc: a case report (CAD를 이용한 수직 고경 증가와 monolithic disc를 사용한 총의치 수복 증례)

  • Hyeon, Kim;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.242-248
    • /
    • 2022
  • Recently, through the development of CAD/CAM technology, it is also being used for fabricating dentures. Compared to conventional methods, when digital dentures are fabricated, the fabrication process is facilitated, and the number of visits to hospitals is reduced and errors are reduced. In this case, the vertical dimension was increased using a CAD program in a patient who needed vertical dimension recovery due to the use of old dentures, and the final denture was fabricated using a monolithic disc through the milling method. The centric relation was recorded using existing dentures, and using the information from the intraoral scan and the existing denture model scan, a trial denture was fabricated and delivered to the patient to evaluate the midline and occlusion. Based on the evaluation of the trial denture, the final denture was fabricated using a milling method and a monolithic disc, and the final denture showed satisfactory results functionally and aesthetically.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

Full-mouth rehabilitation of severely attrited dentition with missing posterior teeth: a case report using digital workflow with jaw motion tracking (심한 교모와 구치부 상실을 보이는 환자의 전악 수복: Jaw motion tracking과 digital workflow를 활용한 증례 보고)

  • Chan Young Park;Younghoo Lee;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Hyeong-Seob Kim;Kung-Rock Kwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.293-307
    • /
    • 2023
  • Jaw motion tracking, which is introduced in recent case reports, is a method which records the patient's individualized pathway of the mandibular movements along with facebow transfer, and reproduces the information in the virtual space of computer-aided-design/computer-aided-manufacturing (CAD-CAM) software. In this present case, a collapse of the occlusal plane was observed, due the loss of posterior teeth for a long period. Full-mouth rehabilitation with an increase in the occlusal vertical dimension was planned. First, the patient's mandibular movements were recorded on the newly established jaw relation by jaw tracking, and this information was assembled with the patient's intraoral data to create a virtual patient. Implant planning and diagnostic wax-up was done on the virtual patient, leading the fabrication of the provisional prosthesis. On the newly established jaw relation with an increase in the occlusal vertical dimension, canine guidance of the provisional prosthesis was checked. Finally, the provisional prosthesis was carried out to the definitive prosthesis. Using the advantages of the technologies in the digital dentistry, the patient was satisfied with the function and the esthetics after the treatment.

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

Head & Neck CT Scan Image Evaluation for Implant Surgery Patients (임플란트 시술환자에 대한 두경부 CT검사 영상 평가)

  • Hyung-Seok Hwang;Hyung-Seok Hwang;In-Chul Im
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.843-849
    • /
    • 2023
  • This study attempted to determine the optimal algorithm after quantitatively analyzing noise, SNR, and CNR measurements by reconstructing four algorithms (Standard, Soft, Bone, and Detail) from head and neck CT images of patients who underwent implant surgery. As an analysis method, pixel values were calculated through the region of interest in the reconstructed image using the Image J program. For noise, SNR, and CNR, the region of interest was measured at the location of the pharynx, masseter muscle, and parotid gland in the image, and the mean and SD values were obtained. The values of SNR and CNR were calculated based on the given formula. As a result, the standard algorithm showed the lowest noise and the highest SNR. CNR was highest in the Soft algorithm, but showed no significant difference from the Standard algorithm. Therefore, it is believed that the Standard algorithm is the optimal algorithm for examining patients wearing intraoral implants in head and neck CT examinations. We hope that the data from this study will be used as basic data for image evaluation in head and neck CT examinations, and that the quality of images will be further improved through various algorithm changes. It is believed that this will be an opportunity to do so.

Rational treatment planning for implant treatment of the edentulous patients (완전무치악환자의 전악 임플란트 치료 계획 수립을 위한 체계적인 접근법)

  • Jeong-In Bae
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.2
    • /
    • pp.54-68
    • /
    • 2023
  • Treatment planning of edentulous patient with digital method is materialized by designing the surgical guide. When designing the surgical guide, we first implement the shape of the final prosthesis in the virtual space and then materialize the implantation plan based on this. However, it is challenging to make surgical guides for edentulous patients as their lack of both the reference for the arrangement of teeth and interocclusal relationship makes it hard to envision the shape of the final prosthesis. If there exists good partial or complete dentures or residual teeth, its teeth arrangement can be used as a reference for the virtual final prosthesis and the subsequent surgical guide. If such a reference is absent or unsatisfactory, a process of manufacturing a complete denture for diagnostic purposes and verifying it on patient's mouth is necessary and use it as a new reference for the virtual final prosthesis. But even if a surgical guide is produced through the reference from the thorough reflection of the virtual final prosthesis, when we use it in the surgical field, the intraoral condition of the patient may make the implants deviated from planned in the surgical guide. In the worst case, if the positioning of the surgical guide on the mouth is incorrect, it can lead to a catastrophic error that displaces all the implant, in which case the guided surgery would be much worse than the non-guided one. In this article, we will discuss how to obtain references of tooth arrangements in a timely manner and align or register them into a unified coordinate system in digital space, and also introduce how to transfer such an implantation plan from the virtual world into the patient's mouth of real world with minimum error. And lastly, I would like to express my opinion on the establishment of a rational and systematic protocol of guided surgery of the edentulous patients.

Digital immediate implantation and aesthetic immediate loading on maxillary incisor displaced due to root fracture: a case report (치근파절로 변위된 상악 중절치의 디지털을 이용한 즉시 임플란트 식립 및 심미 수복 증례)

  • Jieun Song;Songyi Park;Chan Park;Kwidug Yun;Hyun-Pil Lim;Sangwon Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.267-275
    • /
    • 2023
  • To obtain better esthetic results when immediately placing a dental implant, the soft tissue surrounding the implant must be conditioned during healing of the extraction socket. To this end, the emergence profile can be customized through immediate restoration of the provisional prosthesis, and good clinical results can be obtained at the time of definitive restoration in the future, resulting in high patient satisfaction. In this case, horizontal root fracture occurred after trauma to both maxillary central incisors. Immediate implant placement and loading was planned considering aesthetics and alveolar bone condition. By taking an impression using a digital intraoral scanner, a digital diagnostic wax-up was performed to make a more aesthetic prosthesis without applying external force to the traumatized teeth. Based on this, the ideal placement location was determined and immediate implant placement was performed using a 3D printed surgical guide. The provisional prosthesis was restored 5 days after placement, and the definitive zirconia crown was restored through soft tissue conditioning and customization using the shape of the provisional prosthesis for 3 months.