• Title/Summary/Keyword: intra class correlation

Search Result 118, Processing Time 0.028 seconds

The validity and reliability of the Korean version of the General Attitudes towards Artificial Intelligence Scale for nursing students (한국어판 간호대학생의 인공지능에 대한 태도 측정도구 신뢰도 및 타당도 검증)

  • Seo, Yon Hee;Ahn, Jung-Won
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.28 no.4
    • /
    • pp.357-367
    • /
    • 2022
  • Purpose: The aim of the study was to verify the validity and reliability of the Korean version of the General Attitudes towards Artificial Intelligence Scale (GAAIS-K) for nursing students. Methods: Data from 235 participants were collected from April 12 to April 26, 2022. A total of 230 participants' data were analyzed. The data were analyzed for content, discriminant, known-groups, and construct validity using content validity index, correlation coefficient, and confirmatory factor analyses. The reliability of the GAAIS-K was examined using internal consistency and test-retest analyses. Results: The expert-rated content validity index was ≥.80. The sub-scales of the GAAIS-K were moderately correlated with attitude toward accepting technology, indicative of its discriminant validity. The male students' positive attitude score was significantly higher than that of the female students, satisfying the known-groups validity. Cronbach's α for the scale was .86 (positive) and .74 (negative), and the intra-class correlation coefficient for the two-week test-retest reliability was .86 (positive) and .60 (negative). The scores for positive and negative attitudes were 3.68±0.46 and 3.05±0.55. Conclusion: This study shows that the GAAIS-K is a valid and reliable instrument for assessing nursing students. Additional research is recommended to continue the evaluation of the GAAIS-K with a focus on healthcare settings.

Reproducibility of Nutrient Intake Estimated by Three-Day 24-Hour Dietary Recall of Middle-Aged Subjects for 6 Month Intervals (자기기록식 3일간의 24시간 회상법의 신뢰도 연구 -서울지역 중년 자원자를 대상으로-)

  • 이미숙;우미경;김성애;오세인;곽충실
    • Korean Journal of Community Nutrition
    • /
    • v.8 no.4
    • /
    • pp.603-609
    • /
    • 2003
  • This study examined the reproducibility of nutrient intakes estimated by the 24-hour recall method in a prospective cohort study (Longitudinal study of aging and health monitoring of Korean elderly) of middle-aged volunteer subjects (42 males and 49 females) in the Seoul area. The three-day 24-hour recall was administered twice at an interval of approximately 6 months. The first data were collected and a corrective procedure was performed by interviewing of the subjects and a trained dietitian. The second data were collected by mail from the subjects without the performance of any corrective procedure. The mean age of the subjects was 53.5 $\pm$ 9.6 for the males and 52.2 $\pm$ 8.9 for the females. The subjects who had above college education were 95% in the case of the males and 60% in the case of the females. The characteristics of the male subjects in this study were that they were highly educated and held professional jobs and were from the middle or upper class. Comparing the first and second 24-hour recall data, the second data showed relatively lower intakes of all nutrients, except vitamin A, vitamin Bi and cholesterol. There was no difference in the nutrients of the first and the second data with respect to vitamin A, vitamin B$_1$ and cholesterol in the males and calcium, iron, sodium, vitamin A, vitamin B$_1$, vitamin B$_2$ and cholesterol in the females. This data may indicate that the 24 hour retail method without a dietitian's help may result in lower reporting of the subject's intakes. The men had a tendency to remember less than the women. Pearson's correlation coefficients with unadjusted nutrient intakes values were ranged from 0.24 to 0.66. When energy intake was adjusted, there was a slight increase (from 0.26 to 0.71). Intra-class correlation coefficients with nutrient-unadjusted values ranged from 0.22 to 0.66, and the energy-adjusted values were ranged from 0.23 to 0.69. The weighted Kappa statistical values ranged from 0.10 to 0.40. On the average,46.3% of the subjects who were found in the lowest quartile of the nutrient intake levels based on the first 24-hour recall, were in the lowest quartile based on the second 24-hour recall. Therefore, there was a low reproducibility between the first and the second 24-hour recall. We should examine the factors influencing low reproducibility. Also, strategies should be developed to maximize the reliability of the assessment, with regard to portion-size training and telephone validation. (Korean J Community Nutrition 8(4) : 603∼609, 2003)

The Reliability and Validity of Smart Insole for Balance and Gait Analysis (균형과 보행분석을 위한 스마트 인솔의 신뢰도와 타당도 분석)

  • Lee, Byoung-Kwon;Han, Dong-Wook;Kim, Chang-Young;Kim, Gi-Young;Park, Dae-Sung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose: The Pedisole is a newly developed shoe-mounted wearable assessment system for analyzing balance and gait. This study aimed to determine the reliability and validity of the parameters provided by the system for static balance and gait analysis of healthy adults. Methods: This study included 38 healthy adults (22.4±1.9 years) with no history of injury in the lower limbs. All participants were asked to perform balance and gait tasks for undertaking measurements. For analysis of balance, both the smart Pedisole and Pedoscan systems were concurrently used to analyze the path length of the center of pressure (COP) and the weight ratio of the left and right for 10 s. Gait was measured using the smart Pedisole and GaitRite walkway systems simultaneously. The participants walked at a self-selected preferred gait speed. The cadence, stance time, swing time, and step time were used to analyze gait characteristics. Using the paired t-test, the intra-class coefficient correlation (ICC) was calculated for reliability. The Spearman correlation was used to assess the validity of the measurements. In total, data for balance from 36 participants and the gait profiles of 37 participants were evaluated. Results: There were significant differences between the COP path lengths (p<.050) derived from the two systems, and a significant correlation was found for COP path length (r=.382~.523) for static balance. The ICC for COP path length and weight ratio was found to be greater than .687, indicating moderate agreement in balance parameters. The ICC of gait parameters was found to be greater than .697 except for stance time, and there was significant correlation (r=.678~.922) with the GaitRite system. Conclusion: The newly developed smart insole-type Pedisole system and the related application are useful, reliable, and valid tools for balance and gait analysis compared to the gold standard Pedoscan and the GaitRite systems in healthy individuals.

Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone loss

  • Hangmiao Lyu;Li Xu;Huimin Ma;Jianxia Hou;Xiaoxia Wang;Yong Wang;Yijiao Zhao;Weiran Li;Xiaotong Li
    • The korean journal of orthodontics
    • /
    • v.53 no.2
    • /
    • pp.77-88
    • /
    • 2023
  • Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland-Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.

Preliminary Psychometric Properties of the Chinese Version of the Work-Related Quality of Life Scale-2 in the Nursing Profession

  • Lin, Shike;Chaiear, Naesinee;Khiewyoo, Jiraporn;Wu, Bin;Johns, Nutjaree Pratheepawanit
    • Safety and Health at Work
    • /
    • v.4 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objectives: As quality of work-life (QWL) among nurses affects both patient care and institutional standards, assessment regarding QWL for the profession is important. Work-related Quality of Life Scale (WRQOLS) is a reliable QWL assessment tool for the nursing profession. To develop a Chinese version of the WRQOLS-2 and to examine its psychometric properties as an instrument to assess QWL for the nursing profession in China. Methods: Forward and back translating procedures were used to develop the Chinese version of WRQOLS-2. Six nursing experts participated in content validity evaluation and 352 registered nurses (RNs) participated in the tests. After a two-week interval, 70 of the RNs were retested. Structural validity was examined by principal components analysis and the Cronbach's alphas calculated. The respective independent sample t-test and intra-class correlation coefficient were used to analyze known-group validity and test-retest reliability. Results: One item was rephrased for adaptation to Chinese organizational cultures. The content validity index of the scale was 0.98. Principal components analysis resulted in a seven-factor model, accounting for 62% of total variance, with Cronbach's alphas for subscales ranging from 0.71 to 0.88. Known-group validity was established in the assessment results of the participants in permanent employment vs. contract employment (t = 2.895, p < 0.01). Good test-retest reliability was observed (r = 0.88, p < 0.01). Conclusion: The translated Chinese version of the WRQOLS-2 has sufficient validity and reliability so that it can be used to evaluate the QWL among nurses in mainland China.

Comparative Simulation Studies on Generalized Binomial Models (일반화 이항모형의 적합도 평가)

  • Baik, E.J.;Kim, K.Y.
    • Communications for Statistical Applications and Methods
    • /
    • v.18 no.4
    • /
    • pp.507-516
    • /
    • 2011
  • Comparative studies on generalized binomial models (Moon, 2003; Ng, 1989; Paul, 1985; Kupper and Haseman, 1978; Griffiths, 1973) are restrictive in that the models compared are rather limited and MSE of the estimates is the only measure considered for the model adequacy. This paper is aimed to report simulation results which provide possible guidelines for selecting a proper model. We examine Pearson type of goodness-of-fit statistic to its degrees of freedom and AIC for the overall model quality. MSE and Bias of the individual estimates are also considered as the component fit measures. Performance of some models varies widely for a certain range of the parameter space while most of the models are quite competent. Our evaluation shows that the Extended Beta-Binomial model (Prentice, 1986) turns out to be particularly favorable in the point that it provides consistently excellent fit almost all over the values of the intra-class correlation coefficient and the probability of success.

A Study of Sample Size for Two-Stage Cluster Sampling (이단계 집락추출에서의 표본크기에 대한 연구)

  • Song, Jong-Ho;Jea, Hea-Sung;Park, Min-Gue
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.2
    • /
    • pp.393-400
    • /
    • 2011
  • In a large scale survey, cluster sampling design in which a set of observation units called clusters are selected is often used to satisfy practical restrictions on time and cost. Especially, a two stage cluster sampling design is preferred when a strong intra-class correlation exists among observation units. The sample Primary Sampling Unit(PSU) and Secondary Sampling Unit(SSU) size for a two stage cluster sample is determined by the survey cost and precision of the estimator calculated. For this study, we derive the optimal sample PSU and SSU size when the population SSU size across the PSU are di erent by extending the result obtained under the assumption that all PSU have the same number of SSU. The results on the sample size are then applied to the $4^{th}$ Korea Hospital Discharge results and is compared to the conventional method. We also propose the optimal sample SSU (discharged patients) size for the $7^{th}$ Korea Hospital Discharge Survey.

The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients (만성 편마비 환자의 modified Emory Functional Ambulation Profile의 임상 적용)

  • Kim, Seong-Yeol;Lee, Je-Hoon;An, Seung-Heon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.655-666
    • /
    • 2010
  • Purpose : The examine the reliability and validity of the modified Emory Functional Ambulation Profile(mEFAP) for assessing gait function in chronic stroke patients. Methods : A total of 45 stroke patients, who had a stroke more than 6 months, participated in the study. Reliability was determined by Intra-class Correlation Coefficient($ICC_{3,1}$), including Bland and Altman method (Standard Error of Measurement: SEM, Small Real Differences: SRD). Validity was examined by correlating results to the gait ability(mEFAP, Modified Motor Assessment Scale-Gait(MMAS-G), Scandinavian Stroke Scale-Gait(SSS-G), Functional Ambulation Category(FAC), 10m Waking Test(10m WT)), and Fugl Meyer-Lower/Extremity(FM-L/E), Berg Balance Scale(BBS). Results : Inter-rater reliability for the total mEFAP was High($ICC_{2,1}$=.998), and absolute reliability were excellent (SEM: 1.75, SRD: 4.85). Subjects without assistance factor performed better on all tests than did subjects who had stroke. There were significant correlations between the mEFAP and MMAS-G, SSS-G, FAC(r=-.66~-.79), 10 m WT(r=-.86), and FM-L/E, BBS(r=-.72~-.78), indicating good validity. Increased times on the mEFAP correlated with poor performance on the gait ability, motor function of lower extremity, BBS and slow gait speeds on the 10 m WT in stroke patients. Conclusion : The mEFAP can be administered easily and comprehensively. It is a reliable gait assessment tool for patients with stroke and correlated with known of function, the mEFAP may be a clinically useful measure of ambulation.

Study on Reliability and Validity of the 'Qi Blood Yin Yang Deficiency Questionnaire' (기혈음양허손 변증 설문지의 신뢰도 및 타당도 기초연구)

  • Kim, Ji Hye;Ku, Bon Cho;Kim, Jung Eun;Kim, Yoon Sik;Kim, Keun Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.3
    • /
    • pp.346-354
    • /
    • 2014
  • The study was performed to determine the reliability and validity of the 'Qi Blood Yin Yang Deficiency Questionnaire (Qi Blood Yin Yang DQ)' for the 100 subjects with chronic fatigue. After 100 subjects respond to the 'Qi Blood Yin Yang DQ', Korean medical doctor classified the subjects into 4 groups such as Qi deficiency group, Blood deficiency group, Yin deficiency group and Yang deficiency group. 100 subjects were retested in the same way after 3 weeks. The reliability and the validity of the questionnaire were inspected. Internal consistency of the 'Qi Blood Yin Yang DQ' was excellent (Cronbach alpha 0.916). Test-retest reliability was good (intra-class correlation coefficient 0.699). Construct validity analyzed by exploratory factor analysis produced 4 factors, which were selected from eigenvalues that are greater than 1.0. The 'Qi Blood Yin Yang DQ' consisted of 4 factors. The factor 1, 2, 3 and 4 showed 'Qi deficiency', 'Yin deficiency', 'Yang deficiency' and 'Blood deficiency' respectively. The 'Qi Blood Yin Yang DQ' restructured in this study may provide a fundamental questionnaire and a further study is required for a more advanced, standardized and statistically proven questionnaire.

CT-based quantitative evaluation of radiation-induced lung fibrosis: a study of interobserver and intraobserver variations

  • Heo, Jaesung;Cho, Oyeon;Noh, O Kyu;O, Young-Taek;Chun, Mison;Kim, Mi-Hwa;Park, Hae-Jin
    • Radiation Oncology Journal
    • /
    • v.32 no.1
    • /
    • pp.43-47
    • /
    • 2014
  • Purpose: The degree of radiation-induced lung fibrosis (RILF) can be measured quantitatively by fibrosis volume (VF) on chest computed tomography (CT) scan. The purpose of this study was to investigate the interobserver and intraobserver variability in CT-based measurement of VF. Materials and Methods: We selected 10 non-small cell lung cancer patients developed with RILF after postoperative radiation therapy (PORT) and delineated VF on the follow-up chest CT scanned at more than 6 months after radiotherapy. Three radiation oncologists independently delineated VF to investigate the interobserver variability. Three times of delineation of VF was performed by two radiation oncologists for the analysis of intraobserver variability. We analysed the concordance index (CI) and inter/intra-class correlation coefficient (ICC). Results: The median CI was 0.61 (range, 0.44 to 0.68) for interobserver variability and the median CIs for intraobserver variability were 0.69 (range, 0.65 to 0.79) and 0.61(range, 0.55 to 0.65) by two observers. The ICC for interobserver variability was 0.974 (p < 0.001) and ICCs for intraobserver variability were 0.996 (p < 0.001) and 0.991 (p < 0.001), respectively. Conclusion: CT-based measurement of VF with patients who received PORT was a highly consistent and reproducible quantitative method between and within observers.