• Title/Summary/Keyword: intervals between sizes

Search Result 59, Processing Time 0.027 seconds

Establishment of a [18F]-FDG-PET/MRI Imaging Protocol for Gastric Cancer PDX as a Preclinical Research Tool

  • Bae, Seong-Woo;Berlth, Felix;Jeong, Kyoung-Yun;Suh, Yun-Suhk;Kong, Seong-Ho;Lee, Hyuk-Joon;Kim, Woo Ho;Chung, June-Key;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.20 no.1
    • /
    • pp.60-71
    • /
    • 2020
  • Purpose: The utility of 18-fluordesoxyglucose positron emission tomography ([18F]-FDG-PET) combined with computer tomography or magnetic resonance imaging (MRI) in gastric cancer remains controversial and a rationale for patient selection is desired. This study aims to establish a preclinical patient-derived xenograft (PDX) based [18F]-FDG-PET/MRI protocol for gastric cancer and compare different PDX models regarding tumor growth and FDG uptake. Materials and Methods: Female BALB/c nu/nu mice were implanted orthotopically and subcutaneously with gastric cancer PDX. [18F]-FDG-PET/MRI scanning protocol evaluation included different tumor sizes, FDG doses, scanning intervals, and organ-specific uptake. FDG avidity of similar PDX cases were compared between ortho- and heterotopic tumor implantation methods. Microscopic and immunohistochemical investigations were performed to confirm tumor growth and correlate the glycolysis markers glucose transporter 1 (GLUT1) and hexokinase 2 (HK2) with FDG uptake. Results: Organ-specific uptake analysis showed specific FDG avidity of the tumor tissue. Standard scanning protocol was determined to include 150 μCi FDG injection dose and scanning after one hour. Comparison of heterotopic and orthotopic implanted mice revealed a long growth interval for orthotopic models with a high uptake in similar PDX tissues. The H-score of GLUT1 and HK2 expression in tumor cells correlated with the measured maximal standardized uptake value values (GLUT1: Pearson r=0.743, P=0.009; HK2: Pearson r=0.605, P=0.049). Conclusions: This preclinical gastric cancer PDX based [18F]-FDG-PET/MRI protocol reveals tumor specific FDG uptake and shows correlation to glucose metabolic proteins. Our findings provide a PET/MRI PDX model that can be applicable for translational gastric cancer research.

The Actual Wearing Conditions and Preferred Design of Tailored Jackets for Obese Women in Their 20s and 30s (20~30대 비만여성의 테일러드 재킷 착용실태 및 선호디자인)

  • Oh, Young-Soon;Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.9
    • /
    • pp.1479-1490
    • /
    • 2010
  • This study provides basic data for the development of jacket patterns which reflect designs corresponding to the body shape features and preferences of obese women in their 20s and 30s by understanding problems they may encounter in wearing a ready-made jacket by researching the reality of ready-made tailored jacket wearing and their design preferences. A survey was conducted by sampling 82 obese women (over $25kg/m^2$ BMI) between the ages of 20 to 39. The details of the survey consists of general information, interest rate and importance rate on clothes, reality of wearing and purchasing jackets, measurement fits per each part, and preferred designs. SPSS 14.0 was used to analyze the data. The results showed that 76.8% of obese women wore their jackets less than 5 times a month. Those in the 20s wore the jackets more frequently than those in the 30s. The reasons for not wearing jackets frequently included uncomfortableness in activities and unavailability of the correct size. A total of 55% of the total preferred the fitting to be relatively smaller than the body size or tightly fitting. Although in the past, there was a tendency to wear a loose fit to cover the body shape, currently even obese body shapes avoided the loose fit as the tight fit is the trend. In terms of the satisfaction rate for the measurements per each part of jackets, there was a low satisfaction rate for most of the items. For the circumference items such as waist length and chest size, people responded that they were too small and for the length of items such as the length of jacket and sleeve length, people responded that they were too long. This was because the readymade clothes brands increase the length of items and circumference items in uniform in the same intervals when producing large sizes. Both those in the 20s and the 30s preferred a tight fit. In terms of preferred fabric, a wool/spandex mix was most popular and then cotton/spandex. This shows that they prefer those fabrics which allow an excellent activity while maintaining the exterior well. In addition, they preferred black color with no patterns because they wanted their body size to look reduced and did not want to receive any attention.

DNMT3B -149 C>T and -579 G>T Polymorphisms and Risk of Gastric and Colorectal Cancer: a Meta-analysis

  • Khoram-Abadi, Khadijeh Mirzaee;Forat-Yazdi, Mohammad;Kheirandish, Shahnaz;Saeidi, Nasim;Zarezade, Zeinab;Mehrabi, Nahid;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.3015-3020
    • /
    • 2016
  • Background: Numerous studies have investigated associations of DNA methyltransferase (DNMT) -149 C>T and -579 G>T polymorphisms with gastric cancer (GC) and colorectal cancer (CRC) susceptibility; however, the findings are inconsistent prompting the present meta-analysis. Materials and Methods: Related studies were identified from PubMed, Google scholar, and SID until 10 October 2015. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were used to assess the strength of the associations. Results: Eleven studies were included based on the search criteria for CRC and GC related to the DNMT3B 149 C>T (3,353 cases and 4,936 controls) and DNMT3B 579 G>T (1,387 cases and 2,064 controls) polymorphisms. There was no significant association overall between DNMT3B -149 and 579 polymorphisms and the risk of cancer. In the stratified analysis by cancer type, DNMT3B 579G>T polymorphism was associated with the risk of CRC and GC. While the DNMT3B -149C/T polymorphism was related with a significantly increased risk of CRC in two tested models, dominant (GG+GT vs. TT: OR 0.51, 95 % CI 0.38-0.69; P = 0.00, Pheterogeneity=0.69, $I^2=0%$) and heterozygote (GT vs. TT: OR 0.50, 95 % CI 0.37-0.69; P=0.00, Pheterogeneity=0.41, $I^2=0%$), no evidence of any association with GC risk was observed as in the pooled analyses. Conclusions: More studies are needed to assess associations of DNMT3B -149C/T and DNMT3B 579G>T polymorphisms with cancer in different ethnicities with large population sizes to generate comprehensive conclusions.

Blend Characteristics of PBT, Nylon6,12 and Preparation of PBT/Nylon6,12 Micro Fiber with Core/shell Structure and their Extrusion Conditions (PBT와 Nylon6,12의 블렌드 특성과 core/shell 구조를 갖는 PBT/Nylon6,12 미세모의 제조 및 압출조건)

  • Park, Hui-Man;Lee, Seon-Ho;Kwak, Noh-Seok;Hwang, Chi Won;Park, Sung-Gyu;Hwang, Taek Sung
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1068-1075
    • /
    • 2012
  • Poly(butylene terephthalate) (PBT)/Nylon6,12 core/shell micro fiber were prepared by extrusion molding. To investigate their optimum extrusion conditions, compatibility of PBT/Nylon6,12 blend micro fiber in conformity to their weight ratio and manufacture temperature was explored with SEM morphology and DSC. The alterations in their mechanical properties by extrusion speed were compared and analyzed through a UTM. In comparison with SEM figures, the domain sizes of Nylon6,12 were gradually declined by increasing the extrusion temperature of blends. Furthermore, according to these SEM images, the phase separation between Nylon6,12 domain and PBT matrix became indistinct with increasing of weight percentage of Nylon6,12. In case of DSC, the boundaries of two peaks were almost disappeared when increasing the extrusion temperature and also intervals of each two melting peaks became narrow as increasing the Nylon6,12 ratio. The mechanical properties including tensile strength, elongation, flexural strength and flexural modulus were increased as the increase in the extrusion temperature until $260^{\circ}C$. However, the mechanical properties were actually deteriorated over $260^{\circ}C$. The tensile strength, elongation, flexural strength and flexural modulus at $260^{\circ}C$ were 560 $kg_f/cm^2$, 220%, 807 $kg_f/cm^2$ and 22,146 $kg_f/cm^2$, respectively. These values are more than intermediate values of mechanical properties of PBT and Nylon6,12. These results mean that there is compatibility between PBT and Nylon6,12. Based on the extrusion conditions that produced optimum compatibility of blend, as a result, our group obtained micro fibers with the core/shell structure.

A Brief Report of the Short-Term Home Range Study of a Pair of Raccoon Dogs(Nyctereutes procyonoides koreensis) in a Rural Area of Gurye, Chonnam Province, South Korea Using Radiotracking Method (전라남도 구례 농촌지역에서의 단기원격무선추적을 이용한 너구리(Nyctereutes procyonoides koreensis) 한 쌍의 행동권에 관한 연구)

  • Kim, Baek-Jun;Choi, Tae-Young;Park, Chong-Hwa;Kim, Young-Jun;Lee, Hang
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.3
    • /
    • pp.230-240
    • /
    • 2008
  • The primary aim of this study is to estimate the home range of a pair of raccoon dogs(Nyctereutes procyonoides koreensis) and to compare with the previous study of raccoon dogs in a rural area of Gurye, the southern part of South Korea. Radiotracking was regularly carried out on 2 raccoon dogs for 2 days every 2 months(in June, August, October and December, 2006). During the 2 days, radiotracking was usually conducted every $1{\sim}3$ hours through day and night. The analysis of tracking data with a total of $46{\sim}64$ bearings showed that the total home range size of the pair was $0.41km^2$, and mean home range size was $0.32km^2$ by 95% minimum convex polygons(MCP) estimate. The home ranges of the male and female were largely overlapping(about $70{\sim}95%$), and the sizes were not very much different from each other. However, there was a big difference between day $(0.01km^2)$ and night-time $(0.35km^2)$ home ranges, and it was largest in summer$(0.56km^2)$ and smallest in winter $(<0.01km^2)$. In addition, the home range of the pair included 1 core area and 4 different feeding areas. In conclusion, our raccoon dog home range data using the same individuals but with more frequent bearings per day and more extended tracking intervals still showed very similar results to the previous study with less frequent bearings per day and more extensive tracking days.

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam (6MV 광자선에서 전자오염 감소에 관한 연구)

  • Lee, Choul-Soo;Yoo, Myung-Jin;Yum, Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 1997
  • Purpose : Secondary electrons generated by interaction between Primary X-rar beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer To reduce the surface dose from the electron contamination, electron filters were attached under the tray when a customized block was used. Materials and Methods : Cu, Al or Cu/Al combined Plate with different thickness was used as a filter and the surface dose reduction was measured for each case. The measurement to find optimal filter was performed with $10m\times10cm$ field size and 78.5cm source to surface distance. The measurement points are positioned with 2mm intervals from surface to maximum build-up point. To acquire the effect of field size dependence on optimal electron filter, the measurement was performed from $4cm\times4cm\;to\;25cm\times25cm$ field sizes. Results : The surface dose was slowly increased by increasing irradiation field but rapidly increased beyond $15cm\times15cm$ field size. Al plate was found to be inadequate filter because of the failure to have surface dose kept lowering than the dose of deep area. Cu 0.5mm plate and Cu/Al=0.28mm/1.5mm combined plate were found to be optimal filters. By using these 2 filters, the absorbed dose to the surface layer was effectively reduced by $5.5\%,\;11.3\%,\;and\;22.3\%$ for the field size $4cm\times4cm,\;10m\times10cm,\;and\;25cm\times25cm$, respectively. Conclusion : The surface dose attributable to electron contamination had a dependence on field size. The electron contamination was increased when tray was used. Specially the electron contamination in the surface layer was greater when the larger field was used. 0.5mm Cu Plate and Cu/Al=0.28mm/15mm combined plates were selected as optimal electron filters. When the optimal electron filter was attached under the tray, excessive surface dose was decreased effectively The effect of these electron filters was better when a larger field was used.

  • PDF

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

An Assessment of the Utility of Respiratory Synchronized Systems in the PET/CT Examination (PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가)

  • Seong, Yong-Jun;Yoon, Seok-Hwan;Hyun, Jun-Ho;Lee, Hong-jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Purpose During PET/CT examinations, the movements of internal organs caused by respiration are captured in images during multiple breathing cycles, resulting in the increases in tumor size and effects on SUV. Respiratory synchronized systems were used to evaluate tumor sizes and SUV changes. Materials and Methods Biograph mCT 64 was used for the equipment, and RPM and Anzai systems were used for the respiratory synchronized systems. We used point source and micro-phantom for an experimentation. We were performed on 12 patients who had solid tumors discovered at the base of the lung or at the top of the liver from August through September 2016. The PET images of the exhalation-to-breathing state and the CT images of the post-exhalation suspension state were gained to evaluate changes in radioactivity concentration (KBq/mL), SUVmax, cylinder diameter (mm), and tumor diameter (cm) under the conventional Static, RPM, and Anzai methods. Results The result of measuring the radioactivity concentration of the point source was RPM 94% and Anzai 91% against Static, respectively. In the two cylinders of different radioactivity in the micro-phantom, the SUVmax increased to RPM 61% and 78%, and Anzai 58% and 77% against Static, whereas the cylinder diameters decreased by RPM -26% and -28%, and Anzai -28% and -26%, each respectively. Among the patients, the SUVmax increased from a minimum of RPM 8.2% to a maximum of 94.4% against Static, and from a minimum of Anzai 7.6% to a maximum of 68.3%, respectively. As for the tumor diameters, a minimum of RPM -7.6% to a maximum of -28.9% were achieved, while the Anzai fell by a minimum of -9.6% to a maximum of -27.7%, respectively. There was no significant difference discovered in the phantom study between the RPM and Anzai, yet there was a meaningful difference in the patients' tumors (P<0.05). Conclusion The respiratory synchronized systems of RPM and Anzai yielded no significant difference in the phantom study in which the respiration was executed at regular intervals. However, it was discovered that the patients had a meaningful difference for the irregular respiratory cycle and inter-system differences. Still, the respiratory synchronized systems would be useful for the accurate diagnosis and SUV measurement as the tumor decreased in size against the existing Static and the SUV increased.

  • PDF

A Study of Changes of Pulmonary Artery Size after Bidirectional Cavopulmonary Shunt (양방향성 상대정맥-폐동맥 단락술 후의 폐동맥 크기 변화에 관한 연구)

  • 지현근;이정렬
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.495-503
    • /
    • 1996
  • The bidirectional cavopulmonary shunt may be useful as an intermediate procedure before Fontal oper- ation in high-risk patients, because it provides adequate relief of cyanosis and relief of ventricular volume overload. But there are no established theory about the effects of bidirectional cavopulmonary shunt on pulmonary arterial development. The purpose of this article is a study of changes of pulmonary artery size after bidirectional cavopulmonary shunt. Ca diac catheterization and angiography procedures were done on 19 patients who underwent bidirectional cavopulmonary shunt from February 1992 to July 1994, their results were reviewed. Preoperative cardiac catheterization and angiography procedures were performed at a mean interval of ).8 $\pm$4.8($\pm$SEM) months before surgery and following catheterization at a mean postoperative interval of 19.6 $\pm$4.8 months. Pulmonary arterial sixte measurement were standardized for body surface area(Pulmon- arty artery index), and for diameter of descending thoracic aorta(McGoon ratio). Patient's age, body stir- face area, pulmonary angioplasty, preoperative McGoon ratio and follow-up intervals were considered as variables. Before bidirectional cavopulmonary shunt, patient's mean age, body surface area, arterial 02 saturation, diameter of right pulmonary artery, diameter of left pulmonary artery, pulmonary artery Index, McGoon ratio were 13.7$\pm$15.6 months, 0.40$\pm$0.12m2, 71.4$\pm$12.4m2, 7.1$\pm$1.7mm, 6.2$\pm$1 , 191.8$\pm$82.7mm21m2, 1.73 $\pm$0.49, respectively. After bidirectional cavopulmonary shunt, the values were changed to 39.9 $\pm$ 16.2 months, 0.58$\pm$0.07 m2, 83.0$\pm$3.8m2, 9.0$\pm$ 1.5 mm, 7.7$\pm$2.0, 197.3$\pm$57.1 mm2/m2, 1.76$\pm$0.32, respect- ively With patients'development (age, body surf'ace area), diameters of pulmonary arteries were increased, but pulmonary artery indices and McGoon ratios were not changed. And there were no effects of age, body surf'ace area, amount of increased 02 saturation, pulmonary angiography and follow-up duration on the increment of pulmonary ar- tery size. But when the McGoon ratio was as low as 1.2, there were significant increase in postoperative pulmonary artery sizes. There was a significant correlation between preoperative pulmonary artery index (PAI) and McGoon ratio (MGR) ; PAI : MGRxl18.0-12.4 In conclusion, bidirectional cavopulmonary shunt provides adequate increment of arterial 02 saturation and does not increase the pulmonary artery size. Further investi ation is mandatory to evaluate the effect of pulsatile bidirectional cavopulmonary shunt on pulmonary artery growth.

  • PDF