• Title/Summary/Keyword: interval volume

Search Result 399, Processing Time 0.026 seconds

A Study on Soot Formation in Premixed Constant-Volume Combustion at High Pressures (高壓下의 定積 豫混合氣燃燒에 있어서 煤煙생成에 關한 硏究)

  • 임재근;배명환;김종일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.589-597
    • /
    • 1992
  • The effect of pressure on soot formation in premixed propane-air combustion is investigated at high pressures over the pressure range of 1 to 5 MPa by using a specially designed constant volume combustion bomb. The combustiom chamber of disk type with eight spark plugs located on the circumference at an interval of 45deg is 100mm in diameter by 14mm thick. The end gases are compressed to high pressures by the eight converging flames. The soot volume fraction in the chamber center during the final stage of combustion at the highest pressure is measured by the in-situ laser extinction technique, and the burnt gas temperature during the same period is measured by the two-color method. It is found that the soot yield rises with 50 to 100% for the respective equivalence ratio range of 1.9-2.2 at an interval of 0.1 when the combustion pressure is increased from 1 to 5 MPa, and that the turbulent flames decrease in the soot yield as compared with the laminar flames because the burnt gas temperatures increase with the drop of heat loss.

Evaluation for Applying Low-Cost Mobile Laser System to Earth Volume Calculation at Construction Site (건설현장에서의 토공량산출을 위한 저가형 모바일 레이저시스템의 적용성 평가)

  • Kim, In Seop
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.6_1
    • /
    • pp.539-547
    • /
    • 2012
  • Volume survey for earthwork is conducted periodically at every month at large scaled construction sites for request payment for the construction. Currently, the earthwork volume is calculated on the overlapped drawing for two cross sections which were created by new and previous surveying data observed by GPS and TS. However the survey is required lots of time and expenses as it is a pin-point surveying method thus surveyors intend to get data only for the heavy undulated topographic features chosen by himself to save time and expenses. Consequently, it causes poor results due to low dense measurement as well as it's not matched with the results by another surveyors. As a result, the conflicts related in earthwork volume calculation often arises among the owner, contractors and sub contractors. In this study, we developed a method to get surveying data for fast and accurate volume calculation using 3D Mobile Laser System and conducted an application test. Also we carried out experiments for topographic survey using MLS to judge for the application additionally. The results showed that we could reduce a time for cross section survey from 48 hours to 2 hours and collected high dense data which have 0.2m interval instead of 3m interval compare with existing method. Also we could make a map which has high accuracy within 10cm in horizontal through topographic survey using MLS.

Influence of Service Characteristics on High Priority Performance Indicators and Standards in the BreastScreen Australia Program

  • Roder, David Murray;Ward, Gail Heather;Farshid, Gelareh;Gill, Peter Grantley
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5901-5908
    • /
    • 2014
  • Background: Data from BreastScreen Australia Screening and Assessment Services (SAS) for 2002-2010 were analysed to determine whether some SAS characteristics were more conducive that others to high screening performance, as indicated by high priority performance indicators and standards. Materials And Methods: Indicators investigated related to: numbers of benign open biopsies, screen-detected invasive cancers, and interval cancers, and wait times between screening and assessment. Multivariate Poisson regression was undertaken using as candidate predictors of performance, SAS size (screening volume), urban or rural location, year of screening, accreditation status, and percentages of clients from culturally and linguistically diverse backgrounds, rural and remote areas, and socio-economically disadvantaged areas. Results: Performance standards for benign biopsies and invasive cancer detection were uniformly met irrespective of SAS location and size. The interval cancer standard was also met, except in 2003 when the 95% confidence interval of the rate still incorporated the national standard. Performance indicators improved over time for: benign open biopsy for second or subsequent screening rounds; rates of invasive breast cancer detection for second or subsequent screening rounds; and rates of small cancer detection. No differences were found over time in interval cancer rates. Interval cancer rates did not differ between non-metropolitan and metropolitan SAS, although state-wide SAS had lower rates. The standard for wait time between screening and assessment (being assessed ${\leq}28$ days) was mostly unmet and this applied in particular to SAS with high percentages of culturally and linguistically diverse women in their screening populations. Conclusions: Gains in performance were observed, and all performance standards were met irrespective of SAS characteristics, except wait times to assessment. Additional descriptive data should be collected on SAS characteristics, and their associations with favourable screening performance, as these may be important when deciding on SAS design

Wake Volume Characteristics Considering Artificial Reef Canyon Intervals Constructed by Flatly Distributed Artificial Reef Set (평면 분산된 인공어초 집합의 어초협곡 간격에 따른 후류체적 특성)

  • Jung, Somi;Kim, Dongha;Na, Won-Bae
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.169-176
    • /
    • 2016
  • Considering the artificial reef (AR) canyon intervals facilitated by flatly distributed placement models, the wake volumes of 25 AR sets were characterized through the following works. First, twenty-five different canyon intervals were established to investigate how the intervals affect the wake volumes of the AR placement models, each with nine cube-type ARs. Second, the element-based finite-volume method was used to facilitate flow analyses. Third, the so-called wake volume concept was adopted, and finally a reasonable placement interval was found based on the size of the wake volumes and the associated unit propagation indices. From the analysis results, it was found that a maximum wake volume of 25.18 m3 was generated when the longitudinal and transverse intervals were fixed at 6 m and 0 m, respectively. Thus, to magnify the wake volume, it is recommended that artificial reefs be placed at intervals of 6 m (3 times the reef length) in the flow direction, with no intervals in the normal direction, implicitly indicating that an intensively stacked placement model is a better option to efficiently secure a larger wake volume for the cube-type ARs.

Assessment of Breast Volume Change after Transverse Rectus Abdominis Myocutaneous Flap

  • Park, Sang Uk;Shim, Jeong Su
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.631-635
    • /
    • 2012
  • Background The evaluation of a breast after breast reconstruction depends on a surgeon's subjective criteria. We used computed tomography (CT) scans to obtain an objective evaluation of the postoperative results by measuring the breast volume of patients who had undergone breast reconstruction using pedicled transverse rectus abdominis myocutaneous (TRAM) flaps. This research will help in the objective postoperative evaluation of reconstructed breasts, and also in the preoperative flap size designs. Methods A total of 27 patients underwent breast reconstruction using pedicled TRAM flaps after mastectomy from September 2007 to July 2010. Of these, 10 patients who were followed up and underwent CT scans 2 or more times during the follow-up period were included in this study. We evaluated the change in breast volume over time using CT scans, and the interval breast volume change between CT scans. Results All of the 10 patients' reconstructed breasts showed a volume decrease over time. The breast volume changes in the intervals between CT scans were as follows: 5.65% decrease between the first CT and second CT scan, 2.3% decrease between the second CT and third CT scan, (statistically significant) and 1.89% decrease between the third CT and forth CT scan. (not statistically significant). Conclusions This research shows the possibility of objectively evaluating the postoperative breast volume changes. The findings will be helpful in designing the size of TRAM flaps to use on defects after mastectomy. Based on these results, we should also closely observe the reconstructed breast volume for at least 2 years.

A study on the breast type and sizing system for 20's and 40's women's brassire

  • 박은미;손희순
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.249-267
    • /
    • 1995
  • The purpose of this study is to analyze breast shape by age, to classify breast types and then to suggest brassiere size chart. The subject of anthropometric measurement were 232 women in 20's and 40's. The direct anthropmetric measurement were analyzed by mean, standard deviation, duncan test, T-test, ANOVA, factor & cluster analysis The results are as follows; 1) as a result of analysis for the measurements, according to the increase of age, the items of height were decreased and the items of width, depth, cir- cumference, length were increased, being obesity and breast points were dropped. So the volume and bottom area of 40's women's breast were lager than 20's women's. The width of breast points was bide by increasing of intereior. 2) as a result of factor analyxis, 5 factors were extracted as important factor of breast shapes(obesity of breast and location of breast point, breast height and volume, upper dimensions of breast/lower dimensions of breast, interior dimensions of breast/exterior dimensions of breast, volume of the lower part and drop of breast) 3) as a reslut of cluster analysis, the breast shape were classified into 4 types. namely, typel has the smallest volume, bottom area of breast and the slenderest breast, type2 was the second obesity type. type3 was middle sized type. type4 has much dropped, wide bottom area of breast and the biggest form. 4) To establish brassiere sizing system, the loss funtion was used to decide interval of under bust girth and cup size of size chart. 20 brassiere sizes were established and the size chart covers 92.2% of all subject.

  • PDF

Precise Sweep Volume Computation Accelerated by GPU (GPU 가속을 이용한 정밀밀한 스웹 볼륨 경계 계산)

  • Lee, Hyunho;Kyung, Minho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.21 no.1
    • /
    • pp.13-21
    • /
    • 2015
  • We present a robust GPU algorithm constructing a sweep volume boundary for a triangular mesh model. Sweeping geometric entities of a triangular mesh object is first approximated to a set of triangles, the envelope of which becomes the outer boundary of the sweep volume. We find the envelope by computing the arrangement of the triangle set and extracting its outmost boundary. To ensure robustness of the algorithm, we adopt random perturbation of sweep vertices and the interval arithmetic using multi-level precisions. The algorithm is implemented to perform most computation on GPU, and as a result it runs two orders of magnitude faster than other algorithms.

FINITE SPEED OF PROPAGATION IN DEGENERATE EINSTEIN BROWNIAN MOTION MODEL

  • HEVAGE, ISANKA GARLI;IBRAGIMOV, AKIF
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.26 no.2
    • /
    • pp.108-120
    • /
    • 2022
  • We considered qualitative behaviour of the generalization of Einstein's model of Brownian motion when the key parameter of the time interval of free jump degenerates. Fluids will be characterised by number of particles per unit volume (density of fluid) at point of observation. Degeneration of the phenomenon manifests in two scenarios: a) flow of the fluid, which is highly dispersing like a non-dense gas and b) flow of fluid far away from the source of flow, when the velocity of the flow is incomparably smaller than the gradient of the density. First, we will show that both types of flows can be modeled using the Einstein paradigm. We will investigate the question: What features will particle flow exhibit if the time interval of the free jump is inverse proportional to the density and its gradient ? We will show that in this scenario, the flow exhibits localization property, namely: if at some moment of time t0 in the region, the gradient of the density or density itself is equal to zero, then for some T during time interval [t0, t0 + T] there is no flow in the region. This directly links to Barenblatt's finite speed of propagation property for the degenerate equation. The method of the proof is very different from Barenblatt's method and based on the application of Ladyzhenskaya - De Giorgi iterative scheme and Vespri - Tedeev technique. From PDE point of view it assumed that solution exists in appropriate Sobolev type of space.

The Numerical Study on the Cobustion Characteristics and the Heat Transfer Characteristics of Heat Exchanger for Condensing Gas Boiler (응축형 가스보일러 연소기의 연소특성 및 열교환기의 열전달특성에 관한 수치적 연구)

  • Kim, S.C.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.71-78
    • /
    • 2001
  • It was numerically studied that characteristics of fluid flow and heat transfer in a tube with disk and annular baffle for heat exchanger of condensing boiler. Using a finite volume technique and CFD code, STAR-CD, the governing equations were solved and the temperature and flow fields were investigated. The interval between tube and annular baffle, height and diameter of baffle were selected as important design parameters, and the effects of these parameters on heat transfer and fluid flow were studied. As a result, in the case of with interval, the pressure was decreased but heat transfer was increased. Also heat transfer was slowly increased as the size of disk and annular baffle were increased and the distance between baffles were decreased.

  • PDF

GNSS-based Parallel Approaches to Increase Airport Capacity (공항용량 향상을 위한 위성항법기반 평행 접근 연구)

  • Shin, Gwon-Sang;Yuh, Song-Hee;Lee, Hyung-Bok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.2
    • /
    • pp.53-59
    • /
    • 2014
  • Simultaneous parallel approaches in all weather conditions should be applied to manage efficiently increasing volume of air traffic flow and solve the problem of delayed arrivals. But All of the airports which have closely-spaced parallel-runways in Korea don't meet the interval-standards for IFR parallel approaches. In that regard, more accurate and safer System should be applied for the Korean airports. GNSS was adopted as an international standard of the next-generation navigation system and many studies and master plans have been activated by stages in Korea. In this paper, the current state of the domestic airports will be analyzed focusing on the interval of parallel runways and future specification of both flight operation system and air-side management will be recommended.