• Title/Summary/Keyword: interrupted flow

Search Result 91, Processing Time 0.033 seconds

Effects of Tape on Heat Transfer and Friction Factor in a Square Channel (사각 채널에 설치된 테이프가 열전달과 마찰계수에 미치는 효과)

  • Ahn, Soo-Whan;Kang, Ho-Keun;Bae, Sung-Taek;Putra, Ary Bachtiar Krishna
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2402-2407
    • /
    • 2007
  • Heat transfer distributions and friction factors in square channels (3.5 ${\times}$ 3.5 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, e/Dh, is kept at 0.057 and test section length-to-hydraulic diameter, L/Dh is 30. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 3.3cm, length of 90cm, and 2.5 turns. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. The following conclusions from the experimental study were drawn as: 1) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 2) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer performance. 3) Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

Effects of Number of Heating Walls on Heat Transfer in the Rough Square Channel with Twisted Tape (테이프가 있는 거친 사각채널에서 가열벽면의 수가 열전달에 미치는 효과)

  • Ahn, S.W.;Kim, M.H.;Bae, S.T.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.17-22
    • /
    • 2006
  • Surface modifications like rib-roughening and displaced insert devices like the twisted tape are commonly used in applications such as compact heat exchangers and cooling systems. In this paper, regionally averaged heat transfer distributions in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. Regionally averaged Nusselt number and channel averaged Nusselt number in turbulent air flows are presented for Reynold numbers from 8,900 to 29,000. We have obtained the following conclusions from the experimental study: 1) The local Nusselt number in the two-sided heated case is higher than that in the four-sided heated condition. 2) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 3) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer coefficient.

  • PDF

A New Method of One Stage Correction of Taussig-Bing Anomaly with Interrupted Aortic Arch -1 case report- (대동맥궁 단절을 동반한 Taussig-Bing 기형에서 새로운 일차적 완전 교정술 - 1례 보고 -)

  • 정종필;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.83-87
    • /
    • 1997
  • Taussig-Bing anomaly is infrequently associated with interrupted aortic arch and size discrepancy of great arteries makes it difficult to undergo arch reconstruction and arterial switch operation. A 20-day old male infant was admitted with the diagnosis of Taussig-Bing anomaly with type B Interrupted aortic arch. Multi-organ failure, due to the diminution of ductal flow, was stabilized after 3 weeks of prostaglandin El and controlled ventilatory support. The surgical correction consisted of VSD closure, arterial swtich and extended aortic arch reconstruction. The marked disparity between the hypoplastic ascending aorta and the dilated main pulmonary artery was overcome by constructing distal neoaorta using both native ascending and descending aortic tissue. The patient was extubated on postoperative 2nd day Postoperative catheterization showed no left ventricular outflow obstruction, no intracardiac shunt, and no incompetence of neoaortic valve.

  • PDF

Incident Detection for Urban Arterial Road by Adopting Car Navigation Data (차량 궤적 데이터를 활용한 도심부 간선도로의 돌발상황 검지)

  • Kim, Tae-Uk;Bae, Sang-Hoon;Jung, Heejin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.4
    • /
    • pp.1-11
    • /
    • 2014
  • Traffic congestion cost is more likely to occur in the inner city than interregional road, and it accounts for about 63.39% of the whole. Therefore, it is important to mitigate traffic congestion of the inner city. Traffic congestion in the urban could be divided into Recurrent congestion and Non-recurrent congestion. Quick and accurate detection of Non-recurrent congestion is also important in order to relieve traffic congestion. The existing studies about incident detection have been variously conducted, however it was limited to Uninterrupted Traffic Flow Facilities such as freeway. Moreover study of incident detection on the interrupted Traffic Flow Facilities is still inadequate due to complex geometric structure such as traffic signals and intersections. Therefore, in this study, incident detection model was constructed using by Artificial Neural Network to aim at urban arterial road that is interrupted traffic flow facility. In the result of the reliability assessment, the detection rate were 46.15% and false alarm rate were 25.00%. These results have a meaning as a result of the initial study aimed at interrupted traffic flow. Furthermore, it demonstrates the possibility that Non-recurrent congestion can be detected by using car navigation data such as car navigator system device.

A Study on Applicability of TRANSIMS to Interrupted Traffic Flow at Road Segments in Urban Area (TRANSIMS의 단속류 네트워크 적용 가능성에 대한 연구)

  • Jung, Kwnagsu;Do, Myungsik;Lee, Jongdal;Lee, Yongdoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1131-1142
    • /
    • 2013
  • This study aims to verify the applicability of TRANSIMS (TRansportion ANalysis SIMulation System) in interrupted traffic flow through calibration and validation process based on observation data; such as headway, traffic volume, speed, and travel time from Dalguberl Boulevard in Dae-gu metropolitan city. On this study, several micro-simulation parameters are derived from the calibration and validation process through performing a headway comparison and applying an ID back tracking methodology. As a result, it is figured out that actual circumstances of Korean roadway; for example, traffic volume per lane, speed, and travel time, can be applied on the TRANSIMS. Especially, it was possible to find out the influence of cell size parameter to traffic flow characteristic of simulation. However, it is hard to conclude that TRANSIMS is applicable to Korean roadway environment with studying particular target area. Therefore, additional studies; such as more case studies with various types of road, signal, and land use, will be required to localize TRANSIMS to Korea.

A Study on the Optimal Aggregation Interval for Travel Time Estimation on the Rural Arterial Interrupted Traffic flow (지방부 간선도로 단속류 통행시간 추정을 위한 적정 집락간격 결정에 관한 연구)

  • Lim Houng-Seak;Lee Seung-Hwan;Lee Hyun-Jae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.2 s.5
    • /
    • pp.129-140
    • /
    • 2004
  • In this paper, we conduct the research about optimal aggregation interval of travel time data on interrupted traffic flow and verify the reliability of AVI collected data by using car plate matching method in RTMS for systematic collection and analysis of link travel time data on interrupted traffic flow rural arterial. We perform Kolmosorov-Smirnov test on AVT collected sample data and on entire population data, and conclude that the sample data does not represent pure random sampling and hence includes sample collection error. We suggest that additional review is necessary to investigate the effectiveness of AVI collected sample data as link representative data. We also develop statistical model by applying two estimation techniques namely point estimation and interval estimation for calculating optimal aggregation interval. We have implemented our model and determine that point estimate is preferable over interval estimate for exactly selecting and deciding optimal aggregation interval. Our final conclusion is that 5-minute aggregation interval is optimal to estimate travel time in RTMS, as is currently being used our investigation is based on AVI data collected from Yang-ji to Yong-in $42^{nd}$ National road.

  • PDF

Characteristics of Heat Transfer in the Channel with Twisted Tape

  • Ahn, Soo-Whan;Kang, Ho-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.122-128
    • /
    • 2007
  • Heat transfer distributions and friction factors in square channels (3.0 ${\times}$ 3.0 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The rib height-to-channel hydraulic diameter ratio, $e/D_h$, is kept at 0.067 and test section length-to-hydraulic diameter ratio, $L/D_h$ is 30. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 2.8 cm, length of 90 cm, and 2.5 turns. Two heating conditions are investigated for test channels with twisted tape inserts and rib turbulators: (1) electric heat uniformly applied to four side walls of the square duct, and (2) electric heat uniformly applied to two opposite ribbed walls of the square channel. Results show that the twisted tape with interrupted ribs provides a higher overall heat transfer performance over the twisted tape with no ribs.

Recrystallization Controlled Deformation of AISI 4140 (AISI 4140 강재의 재결정 제어변형)

  • 조범호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.135-139
    • /
    • 1999
  • The static softening behavior of AISI 4140 could be characterized by the hot torsion test in the temperature ranges of 10$0^{\circ}C$~120$0^{\circ}C$ and strain rate ranges of 0.05/sec~5/sec. Deformation efficiency which was based on dynamic materials model was calculated from flow stress curves obtained continuous deformation. Interrupted deformation was performed with 2 pass deformation in the pass strain ranges of 0.25{{{{ epsilon _p}}}} ~3{{{{ epsilon _p}}}} and interrupted time ranges of 0.5~100sec. The dependences of process variables pass strain ({{{{ epsilon _i}}}}) stain rate ({{{{ {. } atop {$\varepsilon$ } }}}}) temperature (T) and interpass time ({{{{ {t }_{i } }}}}) on static recrystallization (SRX) and metadynamic recrystallization .(MDRX) could be indicidually predicted from the modified Avrami's equations. Comparison of the softening kinetics between MDRX and SRX showed that the rate of MDRX was more rapid than that of SRX for the same deformation variables. Controlled multipass deformations were performed using deformation efficiency static and metadynamic recrystallization of AISI 4140.

  • PDF