• Title/Summary/Keyword: interrupted

Search Result 706, Processing Time 0.026 seconds

Successful Surgical Treatments of Scleral Rupture with Hyphema in a Young Cat (어린 고양이에서 발생한 안구내출혈을 동반한 공막 파열의 수술적 치료)

  • Park, Youngwoo;Jung, Yechan;Lim, Jae Hyun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.127-129
    • /
    • 2015
  • A 3-month-old, female Persian cat was presented with sclera mass. The mass was detected after cat's squeals during the playing with a dog before 2 days. On ophthalmic examination, a $2{\times}5mm$ dark purple colored raised mass was observed 1 mm behind the limbus in the right eye. Anterior chamber was filled with blood and epithelial defect was detected at 2 o'clock in the right central cornea. After general anesthesia, resection of the protruded iris was performed with iris scissors and bipolar cautery. Ruptured sclera and conjunctiva were closed with simple interrupted and simple continuous suture, respectively. Also, irrigation and aspiration (I/A) of the anterior chamber was performed to remove blood clot with bimanual I/A handpiece in the right eye. Four months after the surgery, the right eye was recovered completely and menace response was positive in spite of the retinal lesions.

Mechanical properties of electro gas welds with different discharge amount of slag (용접 슬래그 배출량에 따른 Electro Gas 용접부의 기계적 특성 변화)

  • Goo, Yeon-Baeg;Sung, Hee-Joon;Kim, Kyeong-Ju
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.26-26
    • /
    • 2010
  • EGW process has been applied to joining of ship block with vertical-up position at high production rate. The workability of EGW, however, has been interrupted by too much slag production. Two electrodes EGW showed more severe workability than that of one electrode EGW. Therefore, to understand the effect of discharge amount of EGW slag on workability and mechanical properties, two different slag discharge amount have been controlled at the same welding conditions. The results are as follows; 1) Workability has been improved by any additional slag discharge. 2) Mechanical properties have been deteriorated with any additional slag discharge. 3) Chemical compositions of weld metal have been changed by any additional slag discharge.

  • PDF

Congenital Bronchoesophageal Fistula: A report of one case (선천성 기관지 식도루 -H-자형 수술 1례보고-)

  • Kim, Ja-Eark;Rho, Joon-Rhyang
    • Journal of Chest Surgery
    • /
    • v.12 no.2
    • /
    • pp.110-112
    • /
    • 1979
  • A case of congenital bronchoesophageal fistula was treated surgically. A 45 year-old woman has been suffered from coughing with liquid diet and recurrent pneumonia for 20 years. Esophagogram and bronchoscopy revealed a fistula tract between midesophagus and right lower lobe bronchus just opposite site of the orifice of the superior segmental bronchus. Preoperative laboratory results were normal and Mantoux test was also negative. The fistula was dissected without difficulty and the lumen was covered with intact mucosa and there were no calcified lymph nodes around the lesion. The fistula was divided and closed with interrupted silk sutures on both sides. The postoperative course was uneventful.

  • PDF

Traumatic Funnel Chest due to Blunt Trauma -A Case Report- (둔상에 의한 외상형 누두흉 -1례 보고-)

  • 조규석
    • Journal of Chest Surgery
    • /
    • v.28 no.2
    • /
    • pp.218-220
    • /
    • 1995
  • This 51 years old male patient was admitted to the department of thoracic and cardiovascular surgery via OPD because of anterior chest pain. 7days before admission, He got the chest trauma after traffic accidents,the lateral chest roentgenogram showed complete transverse sternal fracture. He also complained of mild dyspnea. We also noticed that he had depressed anterior chest wall. It looks like funnel chest. The operative findings revealed dislocated & callus formations at the both 4th and 5th costochondral junction and transverse fracture of sternal body between 4th and 5th costochondral junction, the upper end of sternal fracture was situated below the lower end of sternal fracture. The two ends of sternal fracture were situated at the same level and reapproximated the two ends by two-interrupted wire sutures. The patient is well on the road to recovery after the operation.

  • PDF

Surgical Treatment for Acute Caustic Injury of the Hypopharynx, Esophagus, and Stomach -Two Cases- (하인두 및 위의 손상을 동반한 급성 부식성 식도손상의 외과적 치료)

  • Kim, Hyeong-Gon;Lee, Sam-Yun;Choe, Jong-Beom
    • Journal of Chest Surgery
    • /
    • v.28 no.10
    • /
    • pp.935-938
    • /
    • 1995
  • Two cases of severe caustic injury of the hypopharynx, esophagus, and stomach are presented. Restoration of digestive continuity was accomplished by retrosternal isoperistaltic interposition of the transverse and left colon on the post-injury 73rd and 66th day respectively. The upper oro-colon continuity was made by a cervical approach, a vertical incision at the posterior hypopharyngeal wall, and interrupted one-layer sutures using 3-0 Dacron suture materials. The distal continuity was made by colojejunostomy between the transposed colon and proximal jejunum. There was no event after the operation in both cases. The posterior vertical hypopharyngotomy and hypopharyngocolostomy at the early post-injury period may be the preferred procedure to obtain normal deglutition in patients with esophageal stricture associated with hypopharyngeal injury.

  • PDF

Performance Analysis of Hybrid Type HVDC Circuit Breakers in Voltage Source Converter based HVDC System (전압형 HVDC 시스템 적용을 고려한 Hybrid Type HVDC 차단기의 동작 특성 분석)

  • Khan, Umer Amir;Lee, Jong-Gun;Lim, Sung-Woo;Lee, Ho-Yun;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.153-154
    • /
    • 2015
  • Voltage Source Converter HVDC (VSC-HVDC) are a better alternative than conventional thyristor based HVDC systems. Unfortunately, VSC-HVDC's full potential cannot be utilized up till now due to absence of suitable HVDC protection. Recently, hybrid HVDC circuit breakers (HDCCB) have been developed and successfully lab tested. However, their application and feasibility in VSC-HVDC needs to be investigated. In this research paper we have modelled an existing HDCCB and evaluated its impact on fault reduction and interruption in VSC-HVDC systems. The HDCCB was applied in Korean Jeju-Haenam VSC-HVDC system model and its impact was analyzed for HVDC line-to-ground and line-to-line faults. HDCCB successfully interrupted the fault current and prevented the damages to costly IGBTs and converter transformers.

  • PDF

Experimental Study on Local Scour around Bridge Piers by Scour Protection Devices (세굴보호장치에 의한 교각주위의 국부세굴 실험)

  • 최기봉;김응용
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.126-131
    • /
    • 2000
  • This study based on the laboratory works, analyzes factors affecting local scour in order to understand various characteristics of the local scour surrounding bridge piers. Attached with scour protection device as a method for decreasing local scour, it carries out the laboratory experiments and calculates the scour depth. From the experiments attached with the scour protection devices, it seems possible to reduce the scour depth as the protecting plate, column and sacrificial piles are built in the same height with flume bed at pier or footing upstream interrupted falling-flow. And then it could reduce scour depth. The paper presents the following research results: First, the decreasing degree of scour depth is in order of protecting column, protecting plate, sacrificial piles and non-protecting facilities. However, it shows no meaningful difference between protecting column and protecting plate. Second, when $L_p/b$=0.5~1, the decreasing effect of scour depth reached the maximum of 40 percents.

  • PDF

Measurement of Surface Crack Length Using Image Processing Technology (영상처리기법을 이용한 표면균열길이 측정)

  • Nahm, Seung-Hoon;Kim, Yong-Il;Kim, Si-Cheon;Ryu, Dae-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.96-101
    • /
    • 2001
  • The development of a new experimental method is required to easily observe the growth behavior of fatigue cracks. To satisfy the requirement, an image processing technique was introduced to fatigue testing. The length of surface fatigue crack could be successfully measured by the image processing system. At first, the image data of cracks were stored into the computer while the cyclic loading was interrupted. After testing, crack length was determined using image processing software which was developed by ourselves. Block matching method was applied to the detection of surface fatigue cracks. By comparing the data measured by image processing system with the data measured by manual measurement with a microscope, the effectiveness of the image processing system was established. If the proposed method is used to monitor and observe the crack growth behavior automatically, the time and efforts for fatigue test could be dramatically reduced.

  • PDF

A Study on Ultra-precision Fly-cutting of Aluminum Alloy (알루미늄 합금의 초정밀 플라이커팅에 관한 연구)

  • Park Soon-Sub;Lee Ki-Yong;Kim Hyoung-Mo;Hwang Yeon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.233-234
    • /
    • 2006
  • For the machining of freeform surface, fly cutting is one of the key technology to meet profile accuracy and surface roughness simultaneously. Fly cutting can be applied to manufacturing of optical components with complex profile. In this study aluminum alloy was machined in the process of ultra precision fly cutting and investigated optimum machining conditions in terms of feed-rate, pitch per cycle and depth of cut.

  • PDF

Foramen of Morgagni Hernia in Adult - Report of 1 Case - (성인에서 발생한 Morgagni 공 탈장 -1예 보고-)

  • 김성수
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1088-1091
    • /
    • 1989
  • Foramen of Morgagni hernia is the least common type of all congenital diaphragmatic hernias. These foraminal hernias result from a congenital defect in the development or attachment of the diaphragm to the sternum and costal arch. They occur most commonly on the right side, possibly because of pericardial reinforcement of the left. In our case, occurred on the right side and the contents of the hernial sac were omental fat and a part of transverse colon. We performed transthoracic approach for reduction and repair of foraminal hernia with ligation and interrupted mattress sutures of the margin of the defected diaphragm to the posterior part of the sternum and costal cartilage. The postoperative course was uneventful except posttraumatic delirium and discharged at 21st postoperative day.

  • PDF