Experimental Study on Local Scour around Bridge Piers by Scour Protection Devices

세굴보호장치에 의한 교각주위의 국부세굴 실험

  • Published : 2000.03.01

Abstract

This study based on the laboratory works, analyzes factors affecting local scour in order to understand various characteristics of the local scour surrounding bridge piers. Attached with scour protection device as a method for decreasing local scour, it carries out the laboratory experiments and calculates the scour depth. From the experiments attached with the scour protection devices, it seems possible to reduce the scour depth as the protecting plate, column and sacrificial piles are built in the same height with flume bed at pier or footing upstream interrupted falling-flow. And then it could reduce scour depth. The paper presents the following research results: First, the decreasing degree of scour depth is in order of protecting column, protecting plate, sacrificial piles and non-protecting facilities. However, it shows no meaningful difference between protecting column and protecting plate. Second, when $L_p/b$=0.5~1, the decreasing effect of scour depth reached the maximum of 40 percents.

Keywords