• 제목/요약/키워드: interobserver reliabilities

검색결과 7건 처리시간 0.018초

Modified Barthel Index 및 Motor Assessment Scale을 이용한 검사자간의 신뢰도 검사 (Interobserver Reliabilities of Modified Barthel Index, and Motor Assessment Scale in Stroke Patients)

  • 고성규;김춘배
    • 대한한의학회지
    • /
    • 제20권1호
    • /
    • pp.60-65
    • /
    • 1999
  • We have conducted a study of the interobserver reliabilities of Modified Barthel Index and Motor Assessment Scale with 30 patients hospitalized with strokes in the department of circulatory internal medicine, Sang Ji University Oriental Hospital. The observations were performed by two staff and residents in the circulatory internal medicine department. Raters were assigned in random pairs to individual patients. Evaluations were performed independently by the two observers. In order to minimize the impact of fluctuations in the patients' clinical status, the second set of observations immediately followed the first. Each patient was used for only one pair of evaluations. The results were as follows. 1. Mean kappa value of 13 items in Modified Barthel Index(MBD was 0.742, which indicated excellent interobserver reliability. The kappa values indicated almost $perfect({\kappa}:\;0.81-1.00)$ for 4, substantial for $9({\kappa}:\;0.61-0.80)$, and moderate for $2({\kappa}:\;0.41-0.60)$ of 13 items. All items. except Grooming item, showed statistically significant interobserver agreement(p<0.01) 2. Mean kappa value of 8 items. except General tonus, in Motor Assessment Scale(MAS) was 0.823, which indicated excellent interobserver reliability. and this value of Motor Assessment Scale was more high than MBI' s value. 0.81. The kappa values indicated almost perfect for 5, substantial for 3 of 8 items. All items showed statistically significant interobserver agreement(P<0.01).

  • PDF

Measurement of Apparent Diffusion Coefficient Values from Diffusion-Weighted MRI: A Comparison of Manual and Semiautomatic Segmentation Methods

  • Kim, Seong Ho;Choi, Seung Hong;Yoon, Tae Jin;Kim, Tae Min;Lee, Se-Hoon;Park, Chul-Kee;Kim, Ji-Hoon;Sohn, Chul-Ho;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.88-98
    • /
    • 2015
  • Purpose: To compare the interobserver and intraobserver reliability of mean apparent diffusion coefficient (ADC) values using contrast-enhanced (CE) T1 weighted image (WI) and T2WI as structural images between manual and semiautomatic segmentation methods. Materials and Methods: Between January 2011 and May 2013, 28 patients who underwent brain MR with diffusion weighted image (DWI) and were pathologically confirmed as having glioblastoma participated in our study. The ADC values were measured twice in manual and semiautomatic segmentation methods using CE-T1WI and T2WI as structural images to obtain interobserver and intraobserver reliability. Moreover, intraobserver reliabilities of the different segmentation methods were assessed after subgrouping of the patients based on the MR findings. Results: Interobserver and intraobserver reliabilities were high in both manual and semiautomatic segmentation methods on CE-T1WI-based evaluation, while interobserver reliability on T2WI-based evaluation was not high enough to be used in a clinical context. The intraobserver reliability was particularly lower with the T2WI-based semiautomatic segmentation method in the subgroups with involved $lobes{\leq}2$, with partially demarcated tumor borders, poorly demarcated inner margins of the necrotic portion, and with perilesional edema. Conclusion: Both the manual and semiautomatic segmentation methods on CE-T1WI-based evaluation were clinically acceptable in the measurement of mean ADC values with high interobserver and intraobserver reliabilities.

Reliability of cone-beam computed tomography for temporomandibular joint analysis

  • Gorucu-Coskuner, Hande;Atik, Ezgi;El, Hakan
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.81-88
    • /
    • 2019
  • Objective: The aim was to assess the intraobserver and interobserver reliabilities of temporomandibular joint linear measurements and condylar shape classifications performed with cone-beam computed tomography (CBCT). Methods: CBCT images of 30 patients were measured at two different time points by two orthodontists using the Dolphin 3D program (n = 60). Anterior, posterior, and superior joint space measurements and sagittal joint morphology classification in the sagittal view and medial and lateral joint space and mediolateral width measurements and coronal joint morphology classification in the coronal view were recorded. Intraclass-interclass correlation coefficients (ICC) and kappa statistics were used to assess intraobserver and interobserver reliability for the measurements and morphology classifications, respectively. Results: The ICC values were good for measurements of the posterior joint space by observer I and for measurements of the posterior, medial, and lateral joint spaces by observer II, while the other intraobserver measurements were excellent. Only the mediolateral width measurements showed excellent interobserver ICC values, while the other measurements showed good interobserver ICC values. Intraobserver agreement for the sagittal morphology classifications was moderate (${\kappa}=0.479$) and almost perfect (${\kappa}=0.858$) for observers I and II, respectively, while the corresponding agreement for the coronal morphology classifications was substantial for both observers. The interobserver agreement values for sagittal and coronal morphology classifications were slight (${\kappa}=0.181$) and fair (${\kappa}=0.265$), respectively. Conclusions: Linear temporomandibular joint measurements were reproducible and reliable in both intraobserver and interobserver evaluations. However, interobserver agreement for assessments of condylar shape was low.

Personal technique for definite repair of complete unilateral cleft lip: modified Millard technique

  • Han, Kihwan;Park, Jeongseob;Lee, Seongwon;Jeong, Woonhyeok
    • 대한두개안면성형외과학회지
    • /
    • 제19권1호
    • /
    • pp.3-12
    • /
    • 2018
  • Background: Millard's rotation-advancement repair, which is used by many surgeons, can make a natural philtral column, but most surgeons use a modification of the rotation-advancement flap. The purpose of this article is to introduce a modification utilized by the authors and to provide detailed surgical procedure. Methods: We retrospectively reviewed 82 patients' medical records and presented surgical technique and outcomes. The main features of the authors' strategy are emphasizing horizontal length of the lip, orbicularis oris muscle duplication for improving the definition of the philtral column, overcorrection of domal portion than the non-cleft side in order to compensate for the recurrence during growth. Two judges rated two times the appearance of the patients' nose and lip using Asher-McDade aesthetic index. Intra- and interobserver reliabilities were determined using Cohen's kappa statistics. Results: All patients recovered eventually after surgery; however, two patients have a minor complications (wound infection in one patient, wound disruption due to trauma in the other patient). The improvement of the aesthetic results can be achieved with this modified Millard technique. Total mean scores of the Asher-McDade index was 2.08, fair to good appearance. The intraobserver reliabilities were substantial to almost perfect agreement and the interobserver reliabilities were moderate to almost perfect agreement. Conclusion: We modified Millard method for repair of complete unilateral cleft lip. The surgical outcomes were favorable in long-term follow-up. We hope our technique will serve as a guide for those new to the procedure.

근위 갈매기 절골술 시행 전과 후의 원위 중족골 관절면각의 측정에 대한 신뢰성의 변화 (Change of Reliability for Distal Metatarsal Articular Angle Measurement before and after Proximal Chevron Osteotomy)

  • 박철현;이동열
    • 대한족부족관절학회지
    • /
    • 제20권4호
    • /
    • pp.145-151
    • /
    • 2016
  • Purpose: To evaluate the reliability of preoperative and postoperative distal metatarsal articular angle (DMAA) measurements and to determine whether such reliability is different in accordance with the foot and ankle fellowship and the number of years in practice. Materials and Methods: Between July 2012 and June 2014, a total of 20 patients (24 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic hallux valgus deformity. DMAA were measured twice with an interval of two weeks between the preoperative and postoperative dorsoplantar radiographs by four observers; two of whom were foot and ankle surgeons (A and B), one knee surgeon, and one senior resident. The intraobserver reproducibility and interobserver reliability were assessed by intraclass correlation coefficients. Moreover, the limit of agreement between the preoperative and postoperative DMAA measurements were assessed using a Bland-Altman plot. Results: The intraobserver reproducibility of the foot and ankle surgeon A, knee surgeon, and senior resident improved from 0.796, 0.575, and 0.586 preoperatively to 0.968, 0.864, and 0.864 postoperatively, respectively. The interobserver reliability of foot and ankle surgeon A-B, foot and ankle surgeon A-knee surgeon, and foot and ankle surgeon A-senior resident improved from 0.874, 0.688, and 0.677 preoperatively to 0.971, 0.917, and 0.838 postoperatively, respectively. Conclusion: The intra- and interobserver reliabilities for DMAA measurement improved after proximal chevron osteotomy. Therefore, the necessity of additional procedures to correct the increased DMAA should be reevaluated after proximal chevron osteotomy in the hallux valgus with an increased DMAA.

Digital Tomosynthesis versus Conventional Radiography for Evaluating Osteonecrosis of the Femoral Head

  • Yun Hwa Roh;Seunghun Lee;Jeong Ah Ryu;Yeo Ju Kim;Yeesuk Kim;Jiyoon Bae
    • Korean Journal of Radiology
    • /
    • 제22권12호
    • /
    • pp.2026-2033
    • /
    • 2021
  • Objective: The aim of this study was to compare the diagnostic performances of digital tomosynthesis (DTS) and conventional radiography in detecting osteonecrosis of the femoral head (ONFH) using computed tomography (CT), as the reference standard and evaluate the diagnostic reproducibility of DTS. Materials and Methods: Forty-five patients (24 male and 21 female; age range, 25-77 years) with clinically suspected ONFH underwent anteroposterior radiography, DTS, and CT. Two musculoskeletal radiologists independently evaluated the presence and type of ONFH. The diagnostic performance of radiography and DTS in detecting the presence of ONFH and determining the types of ONFH were evaluated. The interobserver and intraobserver reliabilities of each imaging modality were analyzed using Cohen's kappa. Results: DTS had higher sensitivity (89.4%-100% vs. 74.5%-76.6%) and specificity (97.3%-100% vs. 78.4%-83.8%) for ONFH detection than radiography. DTS showed higher performance than radiography in identifying the subtypes of ONFH with statistical significance in one reader (type 1, 100% vs. 30.8%, p = 0.004; type II, 97.1% vs. 73.5%, p = 0.008). The interobserver agreement was excellent for DTS and moderate for radiography (kappa of 0.86 vs. 0.57, respectively). The intraobserver agreement for DTS was higher than that of radiography (kappa of 0.96 vs. 0.69, respectively). Conclusion: DTS showed higher diagnostic performance and reproducibility than radiography in detecting ONFH. DTS may be used as a first-line diagnostic modality instead of radiography for patients suspected of having ONFH.

디지털 영상을 이용한 무지 외반증 변형각 측정에서 서로 다른 두 계측 방법의 비교 (Comparison of Angle Measurements on Hallux Valgus with Two Different Methods Using Digital Images)

  • 성일훈;김기천;성창호;서우영;이두연;조영아
    • 대한족부족관절학회지
    • /
    • 제17권1호
    • /
    • pp.40-44
    • /
    • 2013
  • Purpose: To study inter- and intra-observer reliabilities of computerized measurements of the angular parameters of hallux valgus deformity, using two different kinds of software tools for angle measurement on the digital radiography. Materials and Methods: On 35 digital radiographies of standing foot anteroposterior view of hallux valgus, two observers (A, B) independently measured hallux valgus angle (HVA) and 1-2 intermetatarsal angle ($IMA_{1-2}$) twice, using two methods. In method I, an angle was determined from duplicated lines to longitudinal axes made for bisecting line on the target bones with software tool. In method II, an angle was calculated automatically and directly from bisecting lines (longitudinal axes) made on the target bones. We compared two methods using paired t-test to determine significance of differences. Inter- and intraobserver reliabilities were evaluated using the intraclass correlation coefficients (ICC). Results: There were no significant differences between measurements of method I and II for each observer (p>0.05) and intraobserver reliability were good. (ICC>0.9) Inter-observer reliability for method I and II was good of the HVA (ICCs, 0.912 and 0.905) and moderate of the $IMA_{1-2}$ (ICCs, 0.505 and 0.537). There were interobserver differences in HVA of method I and II. Conclusion: No significant difference was found statistically between measurements of method I and II. Both methods I and II would be acceptable to measure angular parameters of hallux valgus deformity.