• 제목/요약/키워드: international standards and codes

검색결과 53건 처리시간 0.033초

전력설비에 대한 내오손특성 평가설비 구축 (Construction of the evaluating facilities against contamination characteristic for power installation)

  • 이정기;김민규;정주영;김익수;문인욱;강영식;성문주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1851-1853
    • /
    • 2004
  • The important consideration in laboratory designing and construction of the artificial pollution testing facilities including 300kV, 1800kVA AC test system, which enable to test and evaluate the UHV dielectric performance of power insulators up to transmission class, has been dealt in this paper. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted. With the special consideration concerning other matters in designing of these testing facilities have been described with the fixed ratings and references.

  • PDF

전력기기 내오손특성 평가기반 구축 (Construction of the infrastructure for evaluating characteristic against contamination for power installation)

  • 이정기;김민규;문인욱;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1513-1514
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the artificial pollution testing facilities including 300 kV, 1800 kVA AC test system, which enable to lest and evaluate the UHV dielectric performance of power insulators up to transmission class. Also it is described simply about its trial running of the whole test system. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

Research on Safety-related Communication of Railway Automatic Block Between Railway Stations System

  • Yun, Pei-Yan;Guo, Jin
    • International Journal of Railway
    • /
    • 제2권3호
    • /
    • pp.127-130
    • /
    • 2009
  • The system improves the safety and efficiency of railway transport, combining the advanced axle-counter with single-track semiautomatic block. Using computer, to accomplish relay-based semiautomatic block logic operation and axle-counter to check section status, it will further increase the performance of railway transport. Safety-related communication is one of the important topics in railway signal system. By referring to relevant safety-related communication standards, to research on safety-related communication of Micro-computer automatic block between Railway Stations System, the thesis introduces the basic requirements, concept model, codes, and the process, etc.

  • PDF

Dynamic Characteristics of Water Hammer Arresters for Building Service Applications

  • Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권1호
    • /
    • pp.40-49
    • /
    • 2003
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial code that employs the method of characteristics. Some preliminary results with those arrester models produced in this study agree well with the previously reported. Then, the arrester models have been incorporated into a water supply pipe system of a 59 $m^2$apartment unit constructed by a leading construction company, and their dynamic characteristics have been investigated, especially on the reduction in the water hammer pressure. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure down below 1,082.0 kPa (10.0 kg$g_f$/$cm^2$) when quick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa (4.5 kg$g_f$/$cm^2$). More arresters in the system may be required to meet pressure criteria stated on the related standards and codes.

항만구조물의 사면안정 신 설계기준 연구 (A Study of New Technical Standards for Slope Stability in Port Structures)

  • 윤길림;윤여원;김홍연
    • 한국해안·해양공학회논문집
    • /
    • 제21권4호
    • /
    • pp.316-325
    • /
    • 2009
  • 국제적인 항만시설물 사면안정해석 설계기준을 분석하고 그 결과를 비교하였다. 사면안정해석에 사용된 설계기준은 한계상태 설계법에 근거한 중국, 유럽 및 일본의 설계방법이다. 사면안정해석시 공통적으로 파괴활동면은 원호 활동면 가정을 기본으로 하고 있다. 해석방법에 있어서 중국은 수정 Fellenius법에 근간하고 있으나 근래에 간편 Bishop법으로 변화하고 있다. 유럽은 Morgenstern & Price법 또는 Bishop법을 추천하고 있다. 반면, 일본은 수정 Fellenius법을 우선시하고 간편 Bishop법은 두꺼운 사질토 지반 등에 선택적으로 이용하도록 하고 있다. 특별하게도 유럽은 포괄적 부분계수 및 재료계수를 규정하는 반면, 일본은 각 구조물별로 경험적 재료계수를 명시하고 있다. 중국에서는 포괄적 부분계수의 최소범위를 규정하고, 안정조건에 따라 특정한 시험에 의한 강도지수를 사용하도록 구체적으로 명시하고 있다. 설계사례를 통한 사면안전율을 비교한 결과, 중국, 일본 및유럽 순으로 높게 나타났다.

도시철도 내진성능 보강시스템의 현장부설 적용성 연구 (A Study for the Application Technique of Recently Developed Performance-strengthening Systems in Urban Railway)

  • 김기홍;한영성;한동은;허진호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.843-848
    • /
    • 2011
  • Constructed structures, before the seismic design codes are established was not designed an earthquake resist. So, evaluate seismic performance of structures and appropriate strengthening are required. To seismic reinforcement of railway structures, literature investigation was conducted about a variety of domestic and international processing enhance and repair the existing maintenance. Also, facilities standardization group, in research group of railway standards, when applied the developed seismic reinforcement system to the railway, conducted the survey that can occur the uniqueness for construction. These specific changes that reflect the seismic reinforcement of the system was required to establish application requirements.

  • PDF

A Systems Engineering Approach to Real-Time Data Communication Network for the APR1400

  • Ibrahim, Ahmad Salah;Jung, Jae-cheon
    • 시스템엔지니어링학술지
    • /
    • 제13권2호
    • /
    • pp.9-17
    • /
    • 2017
  • Concept development of a real-time Field Programmable Gate Array (FPGA)-based switched Ethernet data communication network for the Man-Machine Interface System (MMIS) is presented in this paper. The proposed design discussed in this research is based on the systems engineering (SE) approach. The design methodology is effectively developed by defining the concept development stage of the life-cycle model consisting of three successive phases, which are developed and discussed: needs analysis; concept exploration; and concept definition. This life-cycle model is used to develop an FPGA-based time-triggered Ethernet (TTE) switched data communication network for the non-safety division of MMIS system to provide real-time data transfer from the safety control systems to the non-safety division of MMIS and between the non-safety systems including control, monitoring, and information display systems. The original IEEE standard 802.3 Ethernet networks were not typically designed or implemented for providing real-time data transmission, however implementing a network that provides both real-time and on-demand data transmission is achievable using the real-time Ethernet technology. To develop the design effectively, context diagrams are implied. Conformance to the stakeholders needs, system requirements, and relevant codes and standards together with utilizing the TTE technology are used to analyze, synthesize, and develop the MMIS non-safety data communication network of the APR1400 nuclear power plant.

실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구 (A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture)

  • 조성오;김용성
    • 한국실내디자인학회논문집
    • /
    • 제19권3호
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

해양사고 조사매뉴얼의 비교연구 (A Comparative Study on the Investigation Manuals of Marine Accidents)

  • 나송진;김상수;박진수;정재용
    • 한국항해항만학회지
    • /
    • 제26권5호
    • /
    • pp.497-504
    • /
    • 2002
  • 우리나라 해양사고 조사매뉴얼은 국제적인 해양사고 조사지침과 코드 등을 수용하지 못하여 국제 기준과 절차 및 흐름에 뒤떨어져 있고, 새로운 시대와 여건에 맞는 독자적인 조사매뉴얼이 없는 실정이다. 이 연구에서는 한국과 일본 및 미국 해양사고 조사기관의 조사 매뉴얼을 비교ㆍ분석하여 우리나라 조사매뉴얼의 문제점을 도출하고, 우리 실정에 맞는 새로운 조사매뉴얼의 제정 방안을 제시하고자 한다.

Investigating the Effect of Prior Damage on the Post-earthquake Fire Resistance of Reinforced Concrete Portal Frames

  • Ronagh, Hamid Reza;Behnam, Behrouz
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권4호
    • /
    • pp.209-220
    • /
    • 2012
  • Post-earthquake fire (PEF) can lead to a rapid collapse of buildings that have been partially damaged as a result of a prior earthquake. Almost all standards and codes for the design of structures against earthquake ignore the risk of PEF, and thus buildings designed using those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the immediate occupancy (IO), life safety (LS) and collapse prevention (CP) performance levels of two portal frames, after they are pushed to arrive at a certain level of displacement corresponding to the mentioned performance level. This investigation is followed by a fire analysis of the damaged frames, examining the time taken for the damaged frames to collapse. As a point of reference, a fire analysis is also performed for undamaged frames and before the occurrence of earthquake. The results indicate that while there is minor difference between the fire resistances of the fire-alone situation and the frames pushed to the IO level of performance, a notable difference is observed between the fire-alone analysis and the frames pushed to arrive at LS and CP levels of performance and exposed to PEF. The results also show that exposing only the beams to fire results in a higher decline of the fire resistance, compared to exposing only the columns to fire. Furthermore, the results show that the frames pushed to arrive at LS and CP levels of performance collapse in a global collapse mode laterally, whereas at the IO level of performance and fire-alone situation, the collapse mechanism is mostly local through the collapse of beams. Whilst the investigation is conducted for a certain class of portal frames, the results confirm the need for the incorporation of PEF into the process of analysis and design, and provide some quantitative measures on the level of associated effects.