• 제목/요약/키워드: internal values

검색결과 1,677건 처리시간 0.027초

관상동맥질환에서 심장풀스캔을 이용한 최고수축기혈압-수측기말용적곡선의 분석 (The Peak Systolic Pressure-End Systolic Volume Index Relation in Patients with Coronary Artery Disease Using Radionuclide Gated Blood Pool Scintigraphy)

  • 김병태;궁성수;범희승;정준기;박영배;이명철;이영우;고창순
    • 대한핵의학회지
    • /
    • 제21권2호
    • /
    • pp.175-182
    • /
    • 1987
  • For measurement of ventricular performance, ejection fraction (EF) has gained wide acceptance. But EF is influenced not only by changes in muscle function but also by changes in cardiac loading conditions. In case of valvular heart disease which is variable in loading conditions, EF cannot be reliable as an index of myocardial contractility. The end systolic pressure (ESP)-end systolic volume (ESV) relation, howver, is known to represent myocardial contractility, independent of changes in loading conditions. Similar results can be obtained by using peak-systolic pressure (PSP) instead of ESP. To evaluate the utility of the peak systolic pressure-end systolic volume index (PSP-ESVI) relation as an index of myocardial function, we measured $PSP&ESVI$ in 19 partents with coronary artery disease before $(PSP_1\;&\;ESVI_1)$ and after $(PSP_2\;&\;ESVI_2)$ sublingual administration of nitroglycerin. PSP was measured with standard mercury sphygmomanometer during gated blood pool scintigraphic study. ESVI was measured by count derived method after attenuation correction. $PSP_2\;&\;ESVI_2$ measurement was started when the fall of PSP was greater than 5 mmHg after 7-14 minutes post-administration of nitroglycerin. Mean values $({\pm}S.D.)$ of $PSP_1\;&\;ESVI_1$ was $124.9({\pm}20.7)mmHg\;&\;59.4({\pm}39.9)ml/M^2$. Mean values $({\pm}S.D)$ of $PSP_2\;&\;ESVI_2$, was $113.2({\pm}19.9)mmHg\;&\;37.5({\pm}26.1)ml/M^2$. There was a significant difference between mean values of $PSP_1\;&\;PSP_2$, (p<0.01), and mean values of $ESVI_1\;&\;ESVI_2$, (p<0.01). $PSP_1-PSP_2/ESV_1-ESVI_2,\;PSP_1/ESVI_1$ and EF were in the range of 0.14-5.19 mmHg/ml/$M^2$, 0.67-7.68 mmHg/ml/$M^2$ and 10.8%-74.5% respectively. $PSP_1-PSP_2/ESVI_1-ESVI_2$, and EF showed exponential correlation (r=0.85, P<0.01). The correlation coefficient between $PSP_1/ESVI_1$ and EF was 0.73(p<0.01). With the above results, we suggest that $PSP_1-PSP_2/ESVI_1-ESVI_2$, and $PSP_1/ESVI_1$, can be used as an index of myocardial function.

  • PDF

내첨 형광증백제의 형광현상에 영향하는 인자에 대한 연구 (Study on the Factors Influencing the Fluorescence Index of Internal Fluorescent Whitening Agent)

  • 임기백;이지영;김철환;김선영;박종혜
    • 펄프종이기술
    • /
    • 제46권1호
    • /
    • pp.11-17
    • /
    • 2014
  • This study analyzed the effects of specific factors on the fluorescence index of the fluorescent whitening agent (FWA) that is used for internal addition. The specific factors were identified by the literature review, and a statistical survey was carried out to analyze the effects of those factors on the fluorescence index. Bulk, grammage, fillers and internal sizing agents were selected as the specific factors. The paper samples were prepared with internal FWA in a laboratory. The fluorescence indices of the model papers were measured, and p-values of the specific factors on the fluorescence index were calculated by the SPSS program. Most of p-values were greater than 0.05, so the specific factors do not have a significant impact on the internal FWA fluorescence index.

혈청(血淸) ferritin 측정(測定)의 정도관리(精度管理)에 관(關)한 고찰(考察) (A Study on the Quality Control of 2-site Immunoradiometric Assay of Serum Ferritin)

  • 김병국;서일택;김광원;조보연;고창순;이문호
    • 대한핵의학회지
    • /
    • 제14권1호
    • /
    • pp.9-16
    • /
    • 1980
  • A 2-site immunoradiometric assay for serum ferritin was evaluated with commercially available kit. The assay required 6 hours. The slope of the standard curve kept up ideal range with the calculation of maxium binding instead of total dose until expire date. The stage II washing was more important than the stage I washing on the modified washing procedure as the bead keeping to remain in the tube. With this modified mothod, three times of tube. washing was sufficient to reduce the significant errors The measured values of serially diluted sample with standard diluting buffer was proportional to the predicted values. In the experiment of serum effect on the assay. a linear relationship from 5 to 50% serum, but beyond 50% there was reduction in measured ferritin concentration. It has a sensitivity of 2.77 ng/ml, within-assay precision (CV) of 8.0%, and between-assay reproducibility(CV) of 7.4% (mean 174.8 ng/ml).

  • PDF

THE BIDAS-2007: BIOASSAY DATA ANALYSIS SOFTWARE FOR EVALUATING A RADIONUCLIDE INTAKE AND DOSE

  • Lee, Jong-Il;Lee, Tae-Young;Kim, Bong-Whan;Kim, Jang-Lyul
    • Nuclear Engineering and Technology
    • /
    • 제42권1호
    • /
    • pp.109-114
    • /
    • 2010
  • Bioassay data analysis software (BiDAS-2007) has been developed by KAERI, which adds several new functions to its previous version. New functions of the BiDAS-2007 computer code enable the user not only to do a simultaneous analysis by using two or more types of bioassay for the best internal dose evaluation, but also to do a continual internal dose evaluation from a change of the internal exposure conditions such as an intake type (acute, chronic), an intake pathway (inhalation, ingestion), an absorption type (Type F, M, S), and a particle size (AMAD, activity median aerodynamic diameter), and also to estimate the intakes in various conditions of an internal exposure at a time. The values calculated by the BiDAS-2007 code are consistent and in good agreement with those values by IMIE-2004 code by Berkovski and IMBA code by Birchall. The BiDAS-2007 computer code is very useful and user-friendly to estimate the radionuclide intakes and committed effective doses of a radiation worker.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

쌍강탕(雙降湯)이 고(高)cholesterol 식이(食餌)로 유발(誘發)된 고지혈증(高脂血症) 백서(白鼠)에 미치는 영향(影響) (The Effects of Ssanggang-tang($Shu\bar{a}ngji\grave{a}ng-t\bar{a}ng$) on Rat with Induced Hyperlipidemia)

  • 이재휘;임승민;안정조;조현경;김윤식;설인찬;유호룡
    • 대한한방내과학회지
    • /
    • 제29권2호
    • /
    • pp.432-442
    • /
    • 2008
  • Objective : Ssanggang-tang(SGT) is noted as an effective method to treat hyperlipidemia in China. The main purpose of this study was analysis of the effects of Ssanggang-tang(SGT) on rats induced with caused hyperlipidemia. Methods : We observed 3 experimental groups: normal, control, and SGT. Rats were provided a normal diet in the normal group, and the other groups were provided a hyperlipidemic diet to induce hyperlipidemia. After 2 weeks, SGT was treated in the SGT group. For 6 weeks, values related to hyperlipidemia were observed in the 3 experimental groups. Results : SGT decreased some values related to hyperlipidemia like total cholesterol, low density lipoprotein cholesterol(LDL cholesterol), triglyceride, acetocoenzyme A acetyltransferase(ACAT), and 3-hydroxy-3-methylglutaryl coenzyme A reductase(HMG-CoA reductase). However, it showed no effect on weight change or high density lipoprotein cholesterol(HDL cholesterol). Conclusion : These results suggest that SGT might be effective in treatment and prevention of hyperlipidemia.

  • PDF

한방병원에 내원한 암환자 52명에 대한 NK cell Activity 특성 분석 (Analysis of Natural Killer Cell Activity in 52 Cancer Patients at a Korean Medicine Hospital)

  • 이가영;김민지;정진용;유주영;조정효;손창규;이남헌
    • 대한한방내과학회지
    • /
    • 제39권4호
    • /
    • pp.471-479
    • /
    • 2018
  • Objectives: This study was aimed to analyze the correlation of clinical characteristics of cancer patients treated with Korean Medicine and their natural killer cell activity (NKA). Methods: The medical records of 52 cancer patients who conducted NKA test at Cheonan Korean Medicine Hospital of Daejeon University from March 2016 to May 2018 were reviewed. NKA was determined at Seegene Medical institute using NK Vue Gold(R) kit, evaluating activated $IFN-{\gamma}$ by enzyme immunoassay after incubation of whole blood. Careful investigations were conducted by categorizing the patients by their sex, origin, stage, ECOG scale, and conventional treatment type. We used data from the medical records and statistical analysis using SPSS 25.0 V. Results: The average NKA of all patients was $623.1{\pm}722.0pg/mL$. The NKA value was higher for females than for males. No correlation was evident between age and NKA, but patients aged over 70 years had the lowest NKA average result. Stage III and IV patients showed clearly lower NKA values when compared to stage I and II patients. NKA and ECOG scale values showed no evident relationship. Conclusions: This study presented the characteristics of NKA in cancer patients treated with Korean medicine. The NKA result differed by gender and stage. Based on these findings, further study is needed regarding the clinical meaning of NKA.

대한해협주변 내부조석의 계절적 변동성: 3차원 고해상도 모델 연구 (Seasonal Variability of Internal Tides around the Korea Strait: 3-D High-resolution Model Simulation)

  • 이현정;이호진;박재훈;하호경
    • Ocean and Polar Research
    • /
    • 제36권1호
    • /
    • pp.1-12
    • /
    • 2014
  • This study investigates spatial and temporal variations in the generation and propagation of internal tides around the Korea Strait using a three-dimensional high resolution model (Regional Ocean Modeling System; ROMS). The model results were verified through comparison with in-situ current measurements from an array of 12 acoustic Doppler current profilers (ADCPs) deployed in the Korea Strait. Fluxes and distributions of internal tidal energy were calculated using simulation results gathered in February and August. Our analyses reveal that energetic semidiurnal internal tides are generated in a region around the Korea Strait shelf break ($35.5^{\circ}N$, $130^{\circ}{\sim}130.5^{\circ}E$), where the strong cross-slope semidiurnal barotropic tidal currents interact with a sudden topographical change. The semidiurnal internal tidal energy generated in summer displays values about twice as large as values in winter. Propagation of semidiurnal internal tides also reveals seasonal variability. In February, most of the semidiurnal internal tides propagate only into the open basin of the East Sea due to weak stratification in the Korea Strait, which inhibits their southwestward propagation. In August, they propagate southwestward to $35.2^{\circ}N$ along the western channel of the Korea Strait because of strong stratification. In addition, semidiurnal internal tides generated in a region west of Tsushima Island are found to propagate to the coast of Busan. This can be explained by the intensified stratification due to the strong intrusion of bottom cold water in the western channel of the Korea Strait during summer.

향판용(響板用) 오동나무재(材)의 동력학적성질(動力學的性質) (The Dynamic Mechanical Properties of Paulownia coreana Used for Sounding Boards)

  • 홍병화
    • Journal of the Korean Wood Science and Technology
    • /
    • 제13권3호
    • /
    • pp.34-40
    • /
    • 1985
  • The characteristics of Paulownia coreana wood used for sounding boards has been revealed through this study. The 80 specimens were selected from Paulownia coreana wood. The dynamic Young's modulus, the internal friction and resonant frequency of wood were measured by the method of making a rectangular bar resonate in the audio frequency range. The results obtained are summarized as follows: 1. The average values of the specific gravity, the dynamic Young's modulus and the internal friction concerning Paulownia coreana used for sounding boards are $0.252{\pm}0.022$, $(0.494{\pm}0.068){\times}10^{11}$ dyne/cm and $(7.89{\pm}1.692){\times}10^{-3}$ respectively. 2. The average values of resonant frequency, the velosity of sound, and K values are $504{\pm}24.298$ Hz, $5018{\pm}219.83$m/s, and $(9.907{\pm}2.05){\times}10^{-4}$ respectively. 3. The dynamic Young's modulus of Paulownia coreana increases with the increase of the specific gravity, and that on the contrary the internal friction decreases. 4. The dynamic Young's modulus was abruptly decreased as the moisture content of wood specimens was increased up to the fiber saturation point, and the internal friction was linearly increased as the moisture content of wood specimens were increased. 5. The vibration properties of Paulownia coreana are that the dynamic Young's modulus is fairly high, the internal friction is low, and the ratio of Young's modulus to specific gravity shows large value.

  • PDF

칼라영상을 이용한 방울토마토 품질 인자 계측에 관한 연구 (Study on Quality Factor Measurement for Cherry Tomato using Color Imagery)

  • 김대용;오현근;이남근;김영식;조병관
    • 농업과학연구
    • /
    • 제37권2호
    • /
    • pp.303-308
    • /
    • 2010
  • Surface color is the most important quality factor for the grade evaluation of cherry tomato. Color is one of the representative indicators for the maturity which is closely related to the internal quality of cherry tomato, such as firmness, sugar content, and acidity. This study was carried out to investigate the relationship between surface color and internal quality of cherry tomatoes harvested from both hydroponic and soil culture at different ripening stages. To calculate the color values of cherry tomatoes an automatic color imaging system was constructed. A specially designed image processing algorithm for the color measurement was developed. The color values of L*, a*, b* were calculated from the initial color values of RGB and then compared with the internal quality. Statistical analyses indicated that the internal quality was more highly correlated with the surface color than size of cherry tomatoes. Color image features were also investigated to detect external damage of cherry tomatoes. The value of (R value - R mean value)/R mean value was the most effective image feature for the detection of damaged areas on the surface of cherry tomatoes. The results of this study demonstrated the feasibility of color sorting process as an alternative of the conventional drum type size sorting system for cherry tomato industry.