• Title/Summary/Keyword: internal values

Search Result 1,677, Processing Time 0.028 seconds

EFFECT OF CASTING PROCEDURE ON SCREW LOOSENING OF UCLA ABUTMENT IN TWO IMPLANT-ABUTMENT CONNECTION SYSTEMS

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.246-254
    • /
    • 2008
  • STATEMENT OF PROBLEM: The cast abutment has advantages of overcoming angulation problem and esthetic problem. However, when a gold-machined UCLA abutment undergoes casting, the abutment surfaces in contact with the implant may change. PURPOSE: The purpose of this study was to compare the detorque values of prefabricated machined abutments with gold-premachined cast-on UCLA abutments before and after casting in two types of internal implant-abutment connection systems: (1) internal hexagonal joint, (2) internal octagonal joint. Furthermore, the detorque values of two implant-abutment connection systems were compared. MATERIALS AND METHODS: Twenty internal hexagonal implants with an 11-degree taper and twenty internal octagonal implants with an 8-degree taper were acquired. Ten prefabricated titanium abutments and ten gold-premachined UCLA abutments were used for each systems. Each abutment was torqued to 30 N㎝ according to the manufacturer's instructions and detorque value was recorded. The detorque values were measured once more, after casting with gold alloy for UCLA abutment, and preparation for titanium abutments. Group means were calculated and compared using independent t-test and paired t-test (${\alpha}$=0.05). RESULTS: The results were as follows: 1. The detorque values between titanium abutments and UCLA-type abutments showed significant differences in internal octagonal implants (P<0.05), not in internal hexagonal implants (P>0.05). 2. In comparison of internal hexagonal and octagonal implants, the detorque values of titanium abutments had significant differences between two connection systems on the initial analysis (P<0.05), not on the second analysis (P>0.05) and the detorque values of UCLA-type abutments were not significantly different between two connection systems (P>0.05). 3. The detorque values of titanium abutments and UCLA-type abutments decreased significantly on the second analysis than the initial analysis in internal hexagonal implants (P<0.05), not in internal octagonal implants (P>0.05). CONCLUSION: Casting procedures of UCLA-type abutments had no significant effect on screw loosening in internal implant-abutment connection systems, and UCLA-type abutments showed higher detorque values than titanium abutments in internal octagonal implants.

Clinical gap changes after porcelain firing cycles of zirconia fixed dentures

  • Bugurman, Bugurman Burcu;Turker, Sebnem Begum
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.177-184
    • /
    • 2014
  • PURPOSE. The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS. A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05). RESULTS. No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values ($59.54{\mu}m$) were significantly lower than the initial marginal area values ($68.68{\mu}m$)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05). CONCLUSION. The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap.

Korean-specific iodine S values for use in internal dosimetry

  • Tae-Eun Kwon;Yoonsun Chung;Choonsik Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4659-4663
    • /
    • 2023
  • The use of iodine S values derived using the International Commission Radiological Protection (ICRP) phantoms may introduce significant bias in internal dosimetry for Koreans due to anatomical variability. In the current study, we produced an extensive dataset of Korean S values for selected five iodine radioisotopes (I-125, I-129, I131, I-133, and I-134) for use in radiation protection. To calculate S values, we implemented Monte Carlo simulations using the Mesh-type Reference Korean Phantoms (MRKPs), developed in a high-quality/fidelity mesh format. Noticeable differences were observed in S value comparisons between the Korean and ICRP reference phantoms with ratios (Korean/ICRP) widely ranging from 0.16 to 6.2. The majority of S value ratios were lower than the unity in Korean phantoms (interquartile range = 0.47-1.28; mean = 0.96; median = 0.69). The S values provided in the current study will be extensively utilized in iodine internal dosimetry for Koreans.

A Study on Fasting Serum Gastrin level in Normal Subjects and Various Gastric Diseases by Radioimmunoassay (각종(各種) 위질환(胃疾患)에 있어서의 혈청(血淸) gastrin 치(値)에 관(關)한 임상적(臨床的) 연구(硏究))

  • Lee, Yong-Duck;Lee, Heon-Sil;Park, Seung-Uk;Park, Sung-Hwi;Lee, Chong-Suk;Lee, Hak-Choong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.2
    • /
    • pp.67-74
    • /
    • 1981
  • The fasting serum gastrin levels were measured by radioimmunoassay in 32 normal healthy subjects without recognized gastrointestinal symptoms and 90 patients with various gastric diseases, who were visited or admitted to National Medical Center from February to June, 1981. The following results were obtained; 1) The fasting mean serum gastrin level in normal subjects was $55.9{\pm}26.3pg/ml$, and there was no difference between male and female. 2) The gastrin levels in gastric and duodenal ulcer were $85.0{\pm}28.4$ and $76.0{\pm}43.0pg/ml$ respectively, and it's values were elevated as compared with normal subjects. In gastric ulcer, the gastrin level was elevated than that of duodenal ulcer, but no significant difference in each other. 3) The gastrin level in stomach cancer was $89.5{\pm}42.2pg/ml$, and it's values were markedly elevated as compared with values in normal subjects. 4) The gastrin level in gastritis was $73.4{\pm}37.4pg/ml$, and it's values were elevated as compared with values in normal subjects. 5) The gastrin level in post-gastrectomy state was $50.3{\pm}16.3pg/ml$, and it's values were slightly decreased as compared with values in normal subjects.

  • PDF

The Clinical Efficacy of Pasaekhwalhyeol-Tang on Acute Headache of an Acute Cerebral Infarct Patient (급성기 뇌경색 환자의 두통에 대한 파한활혈탕(破寒滑血湯)의 임상적 효능)

  • Shim, Yun-Seub;Seong, Ki-Won
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.318-323
    • /
    • 2004
  • Objectives : The purpose of this clinical study is to evaluate the clinical efficacy of Pasaekhwalhyeol-Tang on acute headache from acute cerebral infarct. Methods : Pasaekhwalhyeol-Tang was prescribed to 15 acute cerebral infarct patients for two weeks. Symptoms were checked and VAS(Visual Analog Scale) scores were kept every week. Results : After prescription of Pasaekhwalhyeol-Tang, VAS scores on headache and accompanying symptoms decreased. No significant changes were shown in laboratory findings. As for the laboratory findings, ALT showed an upward tendency within a week and increased over normal values in two cases(13%). But two weeks later, ALT decreased within normal values. And the mean serum level was within normal values and the other hepatic enzymes did not increase over normal values in either week nor week 2. Conclusions : Results suggest that Pasaekhwalhyeol-Tang is effective in reducing the severity of acute headache from acute cerebral infarct.

  • PDF

Three Cases of Patients Who Showed Abnormal Liver Function Values in Soyangin Gyolhyungjeung Treated with Hyeongbangdojeok-san-gami (형방도적산가미방(荊防導赤散加味方) 투여로 치료한 소양인 결흉증(少陽人 結胸證)으로 변증된 간기능 수치 이상 소견을 보인 환자 증례 보고 3례)

  • Son, Kyung-woo;Park, Soo-ah;Lee, Heun-ju;Baek, Ji-yeong;Nam, Woo-jin
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.2
    • /
    • pp.166-175
    • /
    • 2016
  • Objectives: This case study reports on improvements after treating patients who had abnormal liver function values in Soyangin gyolhyungjeung with Soyangin hyeongbangdojeok-san-gami.Methods: The study was carried out with three patients who showed abnormal liver function values in Soyangin gyolhyungjeung. Liver function tests (LFT) and numerical rating scales (NRS) were used to evaluate symptoms.Results: After we treated three patients with Soyangin hyeongbangdojeok-san-gami, their symptoms and LFT results had improved considerably.Conclusions: Soyangin hyeongbangdojeok-san-gami appears to have a useful effect on abnormal liver function values in Soyangin gyolhyungjeung. Further clinical studies are needed to verify these findings.

A Comparative Study on Korean and Chinese Apparel Attributes according to the Shopping Values of College Students (한국과 중국 대학생들의 쇼핑가치에 따른 의류제품속성에 관한 비교 연구)

  • Jang, Young-Sil;Park, Na-Ri;Park, Jae-Ok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.8
    • /
    • pp.1215-1226
    • /
    • 2009
  • This study classifies consumers according to apparel shopping values to find the differences of apparel attributes in accordance to shopping value segments between Korean and Chinese college students. College students from Seoul and Beijing participated in the study and a quota sampling method collected the data. Data from 504 questionnaires is used for the statistical analysis. A factor analysis through, Cronbach's alpha coefficient, ANOVA, and a post-hoc test are conducted. Two factors of apparel shopping values are classified (hedonic shopping values and utilitarian shopping values). Four segments of apparel shopping value were classified (hedonic shopping, low involvement shopping segment, high involvement shopping, and utilitarian shopping). Three factors of apparel attribute are classified (external attributes, internal/aesthetic attributes, and internal/quality attributes). The result indicate that high involvement shopping segments considered all the clothing attributes more importantly than the other three segments. Chinese respondents of hedonic shopping segments and high involvement shopping segments considered advertisements in terms of external attributes, assembly, and fit in terms of internal/quality performance attributes as more important than Koreans. Chinese respondents of low involvement shopping segments also considered assembly and fit in terms of internal/quality performance attributes as more important than Koreans. Korean respondents of utilitarian shopping segments had a special regard for design and color in terms of internal/aesthetic attributes but the Chinese had a special regard for assembly, fit, and ease of maintenance in terms of internal/quality performance attributes.

Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine (5축 밀링으로 가공한 PMMA 3본 브릿지의 내면 적합도 평가)

  • Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{\pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{\pm}18.2$, $44.8{\pm}10.0$, and $52.1{\pm}8.3{\mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.

Comparison of the Measured Electrical Properties of Pig Internal Organs with the Given Values for Human Organs

  • Jung, Ji-Hyun;Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.161-165
    • /
    • 2012
  • The electrical properties of pig internal organs including lung, liver, heart, kidney, blood, stomach, and small intestine are measured using an open-ended coaxial probe and an improved virtual transmission-line model. The measured complex permittivities of the pig organs are compared with the given values of the corresponding human organs. A similarity between these values is confirmed. For organs such as lung, liver, heart, and kidney that have regular texture and contents, the complex permittivities are almost identical to those of the corresponding human organs. The complex permittivities of human and pig blood are also very close in value. However, relatively large deviations are observed for the cases of stomach and small intestine because the internal contents of these organs significantly affect the measured electrical properties.

Curved beam through matrices associated with support conditions

  • Gimena, Faustino N.;Gonzaga, Pedro;Valdenebro, Jose V.;Goni, Mikel;Reyes-Rubiano, Lorena S.
    • Structural Engineering and Mechanics
    • /
    • v.76 no.3
    • /
    • pp.395-412
    • /
    • 2020
  • In this article, the values of internal force and deformation of a curved beam under any action with the firm or elastic supports are determined by using structural matrices. The article presents the general differential formulation of a curved beam in global coordinates, which is solved in an orderly manner using simple integrals, thus obtaining the transfer matrix expression. The matrix expression of rigidity is obtained through reordering operations on the transfer notation. The support conditions, firm or elastic, provide twelve equations. The objective of this article is the construction of the algebraic system of order twenty-four, twelve transfer equations and twelve support equations, which relates the values of internal force and deformation associated with the two ends of the directrix of the curved beam. This final algebraic system, expressed in matrix form, is divided into two subsystems: twelve algebraic equations of internal force and twelve algebraic equations of deformation. The internal force and deformation values for any point in the curved beam directrix are determined from these values in the initial position. The five examples presented show how to apply the matrix procedures developed in this article, whether they are curved beams with the firm or elastic support.