• Title/Summary/Keyword: internal stability

Search Result 1,123, Processing Time 0.026 seconds

Dispersion Characteristics of Carbon Black Particles in a High Viscous Simulated Solution (고점성 모사용액 내 Carbon Black 입자의 분산특성)

  • Jeong, Kyung-Chai;Eom, Sung-Ho;Kim, Yeon-Ku;Cho, Moon Sung
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.165-170
    • /
    • 2013
  • An external gelation method in place of an internal gelation method applied to the fabrication process of an intermediated compound of Uranium Oxy-Carbide (UCO) kernel spheres for Very High Temperature Reactor (VHTR) fuel preparation is under development in Korea. For the preliminary experiments of the UCO kernel sphere preparation using an external gelation method, the carbon black dispersion experiments were carried out using a simulated broth solution. From the selection experiments of various kinds of carbon black through dispersion experiments in a viscous metal salt solution, Cabot G carbon black was selected owing to its dispersion stability, and the homogeneous dispersing state of carbon black particles in our system. For the effective dispersion of nano-size aggregated carbon black particles in a high viscous liquid, the carbon black particles in a metal salt solution were first de-aggregated with ultrasonic force. The mixed solution was then dispersed secondly by the use of the extremely high-speed agitation with a mechanical mixer of 6000 rpm after feeding the Poly Vinyl Alcohol (PVA) in the solution. This results in the broth solution with good stability and homogeneity alongside no further changes in physical properties.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Job Satisfaction and Commitment of General Hospital Employees (종합병원인력의 직무만족요인과 충성지수)

  • Han, Dong-Woon;Eom, Seung-Sub;Moon, Ok-Ryun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.3 s.51
    • /
    • pp.588-608
    • /
    • 1995
  • This study was intended to enhance the level of hospital personnel management through analysing job satisfaction of hospital employees in terms of structural, personal and environmental variables. The sample of this study consist of a total of 790 persons including doctors, residents, interns, pharmacists, nurses, medical engineers, office workers and manual workers who have worked for general hospitals with 200 beds, 300 beds and 800 beds respectively. The Likert's 5 scales were used for the measurement of satisfaction. The results can be summarized as follows: 1. Structural Variables The level of satisfaction on the job itself was generally low, 2.8 in Likert's 5 scales, with the order of role ambiguity(3.87), routinization(2.6), work overload (2.45) and autonomy(2.37). Hospital employees are aware of their responsibility and they regarded their work as heavy one. The compensatory satisfaction degree was 2.5 which was also low: There were in the order stability(3.1), distributive justice(2.57), pay(2.3) and promotion(1.9). Usually hospital employees showed high degree of stability, while, their satisfaction on promotion possibility is quite low due to specially differentiated structures of hospitals. The degree of satisfaction on the internal conditions of organizational culture was relatively higher as 2.92: They were co-worker's support(3.69), supervisory support(3.15), role conflict(2.64) and welfare(2.17) in order. The satisfaction on welfare as an economic condition was the lowest. 2. Personal Variables The level of satisfaction on personal variables was 3.27 which seemed to be quite high: Contribution to the hospital(3.38), attitude on job performance(3.28) and pride as a member of the hospital(3.07). They seem to believe that their work has been helpful to the performance of hospitals. 3. Environmental Variables The degree of satisfaction on these variables was 3.07 on the average which was derived from environmental factors such as family-role conflict and community support related to hospital employees' environment. The order of satisfaction for each variable is community support(3.2) and family-role conflict(2.94). They turned out to be fairly satisfied with their job in community and yet, they wanted more spare time to spend with their family.

  • PDF

Studies on Microbial Penicillin Amidase (Part 6) Immobilization of Penicillin Amidase from Bacillus megaterium by Adsorption and Acrylamide Gel Entrappment (미생물 페니실린 아미다제에 관한 연구 (제 6 보) 흡착효소의 아크릴아마이드젤 포괄방법에 의한 Bacillus megaterium의 변이주가 생산하는 페니실린 아미다제의 고정화에 관한 연구)

  • Seong, Baik-Lin;Son, Hyeung-Jin;Mheen, Tae-Ick;Moon H. Han
    • Microbiology and Biotechnology Letters
    • /
    • v.9 no.4
    • /
    • pp.197-205
    • /
    • 1981
  • Penicillin amidase of Bacillus megaterium was recovered from the fermentation broth by adsorption on celite and immobilized by entrapping the adsorbed enzyme in acrylamide gel. The operational stability in column reactor was greatly increased by entrappment as compared with that of without entrappment. The optimum pH of the immobilized enzyme was 8.7 with broader activity profile than that of the free enzyme, while the most stable pH range appeared to be between pH 7.5 and 8.0. The optimum temperature was shifted to 5$0^{\circ}C$ from 45$^{\circ}C$ for the soluble enzyme. The values of Km and the inhibition constants for 6-APA( $K_{ia}$ ) and phenylacetic acid ( $K_{ip}$ ), were 4.55 mM, 36.5mM, and 10.5mM, respectively. No significant internal pore diffusion limitation was found since the value of effectiveness factor was 0.95. The operational half life in a column reactor at pH 8.0 was 6.8 days at 4$0^{\circ}C$ and 47 days at 3$0^{\circ}C$, whereas that of without entrappment was only 1 day and 4 days, respectively. The performance of a batch and a column reactor was also discussed with respect to the productivity. The results demonstrated that the entrappment of an adsorbed enzyme for the enhancement of the operational stability of the immobilized enzyme was useful especially when an extracellular enzyme was used.

  • PDF

Effects of Abdominal Draw-in Maneuver, Abdominal Bracing, and Pelvic Compression Belt on Muscle Activities of Gluteus Medius and Trunk During Side-Lying Hip Abduction (옆으로 누워 엉덩관절 벌림운동 시 복부드로우-인, 복부브레이싱, 골반압박벨트가 중간볼기근과 몸통 근육의 활성도에 미치는 영향)

  • Kim, Dong-woo;Kim, Tae-ho
    • Physical Therapy Korea
    • /
    • v.25 no.1
    • /
    • pp.22-30
    • /
    • 2018
  • Background: Improvement of lumbo-pelvic stability can reduce the compensatory action of the quadratus lumborum (QL) and selectively strengthen the gluteus medius (GM) during side-lying hip abduction (SHA). There are abdominal draw-in maneuver (ADIM) and abdominal bracing (AB) as active ways, and pelvic compression belt (PCB) as a passive way to increase of lumbo-pelvic stability. It is necessary to compare how these stabilization methods affect the selective strengthening of the GM. Objects: To investigate the effects of ADIM, AB, and PCB during SHA on the electromyography (EMG) activity of the GM, QL, external oblique (EO) and internal oblique (IO), and the GM/QL EMG activity ratio. Methods: A total of 20 healthy male adults participated in the study. The subjects performed three conditions in side-lying in random order: SHA with ADIM (SHA-ADIM), SHA with AB (SHA-AB), and SHA with PCB (SHA-PCB). To compare the differences among the three conditions, the EMG activities of the GM, QL, EO and IO, and GM/QL EMG activity ratio were analyzed using one-way repeated ANOVA. Results: The EMG activity of the QL was significantly higher in SHA-AB than in SHA-ADIM and SHA-PCB. The GM/QL activity ratio was significantly higher in SHA-PCB than in SHA-ADIM and SHA-AB. In addition, the figure for SHA-ADIM was significantly higher than that for SHA-AB. In the case of the EO, the figure for SHA-AB was significantly higher than corresponding values for the other two conditions. The figure for SHA-ADIM was significantly higher than that for SHA-PCB. The EMG activity of the IO was significantly higher in SHA-AH than in SHA-PCB. Conclusion: It can be suggested that wearing the PCB can more selectively strengthen the GM than to perform ADIM and AB during SHA. In addition, the ADIM can be recommended when there is a need to strengthen abdominal muscles during SHA.

Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder (외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술)

  • Kim, Seung-Ho;Ha, Kwon-Ick;Yoo, Jae-Chul;Lee, Yong-Seuk;Lee, Hui-Dong
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

A study on reduction of springback defects in excavator tank cover part (굴삭기 Tank Cover 부품 뒤틀림 불량 저감에 대한 연구)

  • Jeon, Yong-Jun;Lee, Ha-Sung;Kim, Dong-Earn;Heo, Young-Moo
    • Design & Manufacturing
    • /
    • v.12 no.1
    • /
    • pp.52-57
    • /
    • 2018
  • With the recent strengthening of environmental regulations and the need for cost reduction, excavators, a type of construction equipment, are being miniaturized while components are being developed in consideration of stability. In the case of excavator press parts, mainly high-strength steel sheets are being used to enhance stability and reduce weight. However, in the case of high-strength materials, there is a need to research product forming methods to reduce Springback in defects arising in parts assembly due to Springback that result from the internal residual stress that occurs in press forming being released after product forming. Accordingly, regarding the tank cover, an excavator press-forming part, this study selected a method to reduce distortion through analysis of the Springback occurrence rate and Springback causes through a forming analysis. A forming analysis was conducted for the Springback of the tank cover. Deformations of 13.714 mm in the upper part and 6.244 mm in the inner part of the product occurred, while wrinkles occurred on the sides of the product due to uneven thickness. A forming analysis was conducted for the major shapes of the product to investigate the causes of Springback. Distortion deformation due to the bead in the center of the product was confirmed to be a large factor. A Springback reduction method of correcting uneven thickness in the product sides, a Springback reduction method of removing the bead, and a correction method of restriking after the final forming were used in a forming analysis to determine the degree of Springback reduction. For the forming method to correct uneven thickness in the sides, deformation was reduced by 12% in the upper side compared to the existing model, but deformation in the inner side increased by 1%. For the restriking forming method, deformation decreased by 25% in the upper side and 13% in the inner side. For the bead removal method, deformation decreased by 28% in the upper side and 13% in the inner side, the largest Springback correction results. This indicates that the bead has a large affect on Springback.

Probabilistic Three-Dimensional Slope Stability Analysis on Logarithmic Spiral Failure (대수누선파양에 대한 확률론적 3차원 사면안정해석)

  • 서인석;김영수
    • Geotechnical Engineering
    • /
    • v.10 no.2
    • /
    • pp.121-140
    • /
    • 1994
  • This paper presents the probabilistic model to evaluate the three-dimensional stability of layered deposits and c-0 soil slopes. Rotational slides are assumed with a cylindroid control part terminated with plane ends. And the potential failure surfaces in this study are assumed with the logarithmic spiral curve refracted at boundary of layers. This model takes into consideration the spatial variabilities of soil properties and the uncertainties stemming from insufficient number of samples and the discrepancies between laboratory measured and in -situ values of shear strength parameters. From the probabilistic approxi mate method (FOSM and SOSM method), the mean and variance of safety factor are calculated, respectively. And the programs based on above models is developed and a case study is analysed in detail to study the sensitivity of results to variations in different parameters by using the programs developed in this study. On the basis of thin study the following conclusions could be stated : (1) The sensitivity analysis shown that the probability of failure is more sensitive to the uncertainty of the angle of internal friction than that of the cohesion, (2) The total 3-D proability of failure and the critical width of failure are significantly affected by total width of slope. It is found that the total 3-D probability of failure and the critical width of failure increase with increasing the slope width when seismic forces do not exist and the total 3-D probability of failure increases with increasing the slope width and the critical width of failure decreases when seismic intensity is relatively large, (3) A decrease in the safety factor (due to effect such as a rise in the mean ground water level, lower shear strength parameters, lower values for the correction factors, etc.) would result in reduction in the critical width of failure.

  • PDF

DA-7911, $^{188}Rhenium-tin$ Colloid, as a New Therapeutic Agent of Rheumatoid Arthritis

  • Shin, Chang-Yell;Son, Miwon;Ko, Jun-Il;Jung, Mi-Young;Lee, In-Ki;Kim, Soon-Hoe;Kim, Won-Bae;Jeong, Jae-Min;Song, Yeong-Wook
    • Archives of Pharmacal Research
    • /
    • v.26 no.2
    • /
    • pp.168-172
    • /
    • 2003
  • Radiation synovectomy is one of the most useful methods for treating patients with refractory synovitis because of its convenience, long-term effects, repeatability and the avoidance of surgery. In this study, we investigated the toxicity, stability and biodistribution of a rhenium-188 ($^{188}$Re)-tin colloid to evaluate its suitability as a synovectomy agent. Twenty four hours after injecting the $^{188}$Re-tin colloids (74 KBq/0.1 mL) into the tail vein of ICR mice, most of the $^{188}$Retin colloidal particles was found in the lungs. In addition, there were no particle size changes at either room temperature or at $37^{\circ}C$ after injecting the $^{188}$Re-tin colloids in human plasma and synovial fluid. In vitro stability tests showed that the $^{188}$Re-tin colloid remained in a colloidal form without a critical size variation over a 2-day period. We investigated the leakage of $^{188}$Retin colloids from the intraarticular injection site with gamma counting in New Zealand white rabbits. The $^{188}$Re-tin colloids (55.5 MBq/0.15 mL) were injected at the cavum articular and the mean retention percentage of the $^{188}$Re-tin colloid was 98.7% for 1 day at the injection site, which suggests that there was neither change in the particle size nor leakage at the injection sites. In the biodistribution study with the SD rats, the liver showed the highest radioactivity (0.0427% ID/organ) except for the injected knees (99.49%). In the SD rats, mild toxicities including the skin or a synovium inflammation were observed as a result of a radioactivity of 15 mCi/kg at the intraarticular injection site. However, there was no systemic toxicity. In the Ovalbumin (OVA)-induced arthritic rabbits, the $^{188}$Re-tin colloid improved the macroscopic, the histological score and reduced the knee joint diameter when compared to the arthritic control. In conclusion, a $^{188}$Re-tin-colloid is considered as a strong candidate for radiation synovectomy with a superior efficacy and safety.

The Effects of pH and Alkalinity Adjustment on Internal Corrosion Control and Water Quality in Drinking Water Pipelines (정수의 pH 및 알칼리도 동시 조절이 상수도관의 내부부식 제어 및 수질에 미치는 영향)

  • Lee, Hyun-Dong;Jung, Hae-Ryong;Kwak, Phill-Jae;Chung, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.661-669
    • /
    • 2000
  • This research was carried out to evaluate effect of metallic release and change of water corrosive indices by the pH and alkalinity adjustment using the SDLS (Simulated Distribution Loop System) which consist of six types of pipe loop with DCIP, PVC, PE, STS304, CP, GSP, respectively, and its effects on water quality changes which were microbes quality(SPC), residual chlorine. THMs and other parameters. And it was to propose optimal criteria of water quality control for the field application. According to the results, water control system by pH and alkalinity adjustment showed the changing of corrosive water and reducing of metallic release rate and it was not affects of THMs formation, microbes regrowth and variation of other parameters. Water quality stability and corrosion control were due to calcium carbonate precipitation film formation of pipe inner by water quality control. Therefore, corrosive water control system by pH and alkalinity adjustment can be attributed to effective water quality management in water distribution system according to water quality stability of pH and TIC(Total Inorganic Carbonate concentration) that affect the precipitation and dissolution of solids.

  • PDF