• 제목/요약/키워드: internal resistor

검색결과 27건 처리시간 0.03초

IDENTIFICATION OF RESISTORS IN ELECTRICAL NETWORKS

  • Chung, Soon-Yeong
    • 대한수학회지
    • /
    • 제47권6호
    • /
    • pp.1223-1238
    • /
    • 2010
  • The purpose of this work is to identify the internal structure of the electrical networks with data obtained from only a part of network or the boundary of network. To be precise, it is discussed whether we can identify resistors or electrical conductivities of each link inside networks by the measurement of voltage on the boundary which is induced by a prescribed current on the boundary. As a result, it is shown that the structure of the resistor network can be determined uniquely by only one pair of the data (current, voltage) on the boundary, if the resistors satisfy an appropriate condition. Besides, several useful results about the energy functionals, which means the electrical power, are included.

CdS 셀을 이용한 카오스 발진기 회로 연구 (A Study on a Chaotic Oscillator Circuit with CdS Cell)

  • 박민서;정동호;정경택
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.73-76
    • /
    • 2000
  • We study the Chua oscillator circuit by considering a negative resistor as a characteristic parameter which controlled by the CdS(Cadmium Sulphide) cell. This is a new way to observe several chaotic phenomena with the same initial condition continuously. Since we can control the internal resistance of the CdS cell by an additional circuit, our autonomous chaotic oscillator circuit makes it possible to measure the voltage value continuously and automatically.

  • PDF

Model Tracking Dual Stochastic Controller Design Under Irregular Internal Noises

  • Lee Jong-Bok;Cho Yun-Hyun;Ji Tae-Young;Heo Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.652-657
    • /
    • 2006
  • Although many methods about the control of irregular external noise have been introduced and implemented, it is still necessary to design a controller that will be more effective and efficient methods to exclude for various noises. Accumulation of errors due to model tracking, internal noises (thermal noise, shot noise and 1/f noise) that come from elements such as resistor, diode and transistor etc. in the circuit system and numerical errors due to digital process often destabilize the system and reduce the system performance. New stochastic controller is adopted to remove those noises using conventional controller simultaneously. Design method of a model tracking dual controller is proposed to improve the stability of system while removing external and internal noises. In the study, design process of the model tracking dual stochastic controller is introduced that improves system performance and guarantees robustness under irregular internal noises which can be created internally. The model tracking dual stochastic controller utilizing F-P-K stochastic control technique developed earlier is implemented to reveal its performance via simulation.

수퍼 커패시터의 고장진단을 위한 파라미터의 측정기법과 순시전압강하 보상장치에의 응용사례 (Parameter Measurement Method for Super Capacitor Failure Diagnosis and Application of Voltage Sag Compensation System Using Super Capacitor)

  • 손진근
    • 한국ITS학회 논문지
    • /
    • 제8권6호
    • /
    • pp.173-179
    • /
    • 2009
  • 본 논문에서는 순시전압강하 보상장치 등의 전력변환시스템에 사용되는 수퍼 커패시터(또는 전기이중층콘덴서; EDLC)의 고장진단을 위한 파라미터의 측정기법에 관한 연구를 수행하였다. 직류 에너지의 저장을 위한 기존의 장치에는 납축전지 또는 전해 커패시터를 사용하여 왔으나 환경문제 및 에너지밀도의 측면에서 불리하여 최근에는 수퍼 커패시터의 사용이 주목을 받고 있다. 따라서 본 논문에서는 이러한 수퍼 커패시터의 내부 특성 및 고장 마모 등을 분석하기 위한 커패시터의 등가직렬저항(ESR) 및 정전용량을 측정하는 기법을 제시하여 고장진단의 주요한 데이터에 활용이 가능토록 하였으며, 또한 수퍼 커패시터를 적용한 순간전압강하에 대한 응용 실험을 수행하여 그 결과를 함께 제시하였다.

  • PDF

내연기관 구동 비상용 브러시리스형 동기발전기의 과도특성 개선 (Improvement of Transient Characteristics of Brush-less Type Synchronous Generator for Emergency Driven by Internal-Combustion Engine)

  • 안영주
    • 전기학회논문지P
    • /
    • 제65권4호
    • /
    • pp.268-272
    • /
    • 2016
  • A brush-less type synchronous generator is driven by an internal-combustion engine that is used for emergency source. This kind of generator has to maintain output voltage in a range of some degree under the abrupt load irregular conditions such as a full load trip. This paper suggests a suppression method of increasing the output voltage over the rating. Automatic voltage regulator detects excessive rising of output voltage of the generator and supplies the signals to a switch installed in the rotating exciter through the photo-coupler. The current of main field rapidly decreases by additional resistor of the main filed circuit. Therefore, the output voltage of the generator is maintained effectively. The experimental results verified that the excessive value of the output voltage is limited in the range of 7% of the rated voltage.

초전도 코일의 유도성 에너지에 의한 아크현상과 유기 과전압 (Arc Phenomena and Induced Voltage due to Inductive Energy of Superconducting Coil)

  • 최병주;류경우;성기철;김해종
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.24-30
    • /
    • 2000
  • This paper present the characteristics of the internal induced voltage and arc phenomena in liquid helium at the energy transfer from a superconducting magnet to a load resistor. Especially generation mechanism of the oscillated wave from of the coil terminal voltage is analyzed by considering circuit constant of the superconducting magnet, load condition and arc resistance of the mechanical opening switch. The wavefront and peak portion of the voltage are strongly influenced by arc discharge triggered by the switch separation in liquid helium. Abrupt arc extinction leads to voltage oscillation with an enormous peak. It is suggested that the superconducting magnet should be designed to ensure the internal surge when arc is possibly formed by switch opening or coil short circuit between turns or layers. Finally, a suppression method of the oscillating surge is proposed based on the load condition.

  • PDF

하이브리드 커패시터를 적용한 소형 태양광 전원장치 (The Small Photovoltaic power supply using Hybrid Supercapacitor)

  • 김태엽
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.826-831
    • /
    • 2019
  • 소형 독립형 태양광 전원장치는 조명장치, CCTV 등에 많이 활용되고 있다. 이러한 장치가 경쟁력을 가지기 위해서는 배터리와 같은 전력저장장치 수명이 매우 중요하다. 하이브리드 커패시터는 고밀도와 장수명의 장점을 가지고 있다. 본 논문에서는 하이브리드 커패시터를 이용한 독립형 태양광 전원장치를 제안한다. 전력변환장치의 구성하기 위해 하이브리드 커패시터의 충방전 특성 및 내부저항을 측정하였다. 일사량 변화에도 안정적인 최대 출력점 추종제어 알고리즘을 제시하였다. 제시한 시스템의 타당성을 검증하기 위해 18W의 하이브리드 커패시터와 10W태양광 전지를 이용하여 시제품을 제작하고 실험하였다.

간략화된 배터리 모델이 적용된 IUIa 충전 방식의 에너지 저장장치의 PSCAD/EMTDC 시뮬레이션 모델에 관한 연구 (A Study on the PSCAD/EMTDC Simulation Model of Battery Energy Storage with Simplified Battery Model and IUIa Charging Method)

  • 김성현;이계병;홍준희;손광명
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.84-90
    • /
    • 2010
  • In order to level electric power of the photovoltaic and wind-turbine system and ensure fast response of the fuel-cell and micro-turbine, the energy storage is required in the microgrid system. In this paper, a simplified simulation model of the battery energy storage for charging method with IUIa is developed using PSCAD/EMTDC. The model consists of e.m.f.(electromotive force), internal resistor and overvoltage capacitor. A method for deciding parameters of the model on a case-by-case basis is proposed. The developed model can be used in the simulation of a complicated system such as a microgrid system.

단극발전기의 내부 인자를 적용한 평활필터 설계 (Smoothing Filter Design Applying a Parameter of a Homo-polar Generator)

  • 김인수;성세진
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.409-415
    • /
    • 2007
  • 본 논문에서는 필터 설계시 고려해야 될 주요 항목 중 하나인 성능인자 권장값을 만족시키기 위해 단극 발전기의 내부인자 값을 필터 설계에 반영하는 새로운 평활필터 설계방법을 제안한다. 이 방법은 감쇄용 저항을 배제시킴으로서 평활필터의 효율증대 및 소형화를 기한다. 그리고 성능인자와 함께 공진주파수도 함께 고려함으로서 부성저항 특성을 갖는 고승압 변환기 등을 적용한 시스템의 안정성을 증대시킨다.

직류전압감쇄법을 이용한 전력케이블의 절연열화진단 (Diagnostics of Power Cables using DC Voltage Decay method)

  • 이동영;김상준;김주용;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1688-1691
    • /
    • 1997
  • In this work, we have developed the off-line diagnostic system for power cable insulation using DC voltage decay method to diagnose the insulation degradation of underground power cables. Measurement errors of diagnostic system are less than 1% for $1T{\Omega}$ internal resistor. We have also developed measurement and diagnostic programs for win95 which is suitable for the database construction and the management of data. We could conclude that it is possible to apply this system to the multi-grounded underground cable systems.

  • PDF