• Title/Summary/Keyword: internal radiation exposure

Search Result 134, Processing Time 0.025 seconds

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

Skin malignancy initially misdiagnosed as a benign epidermal cyst

  • Chung, Chan Min;Wee, Sung Jae;Lim, Hyoseob;Cho, Sang Hun;Lee, Jong Wook
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.2
    • /
    • pp.123-126
    • /
    • 2020
  • Skin cancer, which often occurs as a result of skin exposure to ultraviolet light radiation, usually presents with characteristic abnormal features, such as ulcerative lesions, irregular morphology, bleeding, and excessive growth. Therefore, skin cancer rarely resembles a benign tumor on visual inspection. Nonetheless, squamous cell carcinoma and basal cell carcinoma with nodular or polypoid features can have a similar appearance to that of benign tumors, meaning that they are sometimes misdiagnosed as benign. As benign and malignant tumors have some overlapping features, clinicians sometimes use additional imaging techniques such as ultrasonography to improve the accuracy of the diagnosis because even a malignant tumor that externally resembles a benign tumor generally has internal morphological features characteristic of malignancy, such as invasion and irregular borders. However, these imaging tools also have limitations, and punch or excisional biopsy can be needed if malignancy cannot be completely ruled out. Herein, we report a case of skin malignancy initially misdiagnosed as a benign epidermal cyst based on external visual inspection and ultrasonography.

Development of Children's X-ray Imaging Assist Device (어린이 방사선검사 보조기구의 개발)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Ko, Cheol-Woo;Kim, Jong-Ki
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.243-249
    • /
    • 2020
  • Examination with medical radiography is the most significant advances in medicine in the 21st century. Diagnostic imaging occupies an important position in all medical subjects, surgical and internal medicine, including radiology, orthopedics, and neurosurgery. However, the invention associated with conventional radiography devices has focused only on emphasizing the efficient aspects of the examination or obtaining clearer images without considering the age and disease-induced constraints of the patient's posture. The newly developed X-ray aids to solve this problem can effectively perform X-ray imaging of children's who have difficulty communicating and controlling. It is also thought to be a good way to provide accurate imaging information and minimize radiation exposure for children.

Interpretation of Uranium Bioassay Results with the ICRP Respiratory Track and Biokinetic Model (ICRP 호흡기 및 생체역동학적 모델을 이용한 우라늄 생물분석 결과의 해석)

  • Kim, H.K.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.43-50
    • /
    • 2003
  • This study describes a practical method for interpretation of bioassay results of inhaled uranium to assess the committed effective doses both for chronic and acute intake situations. Organs in the body were represented by a series of mathematical compartments for analysis of the behavior of uranium in the body according to the gastrointestinal track model, respiratory track model and biokinetic model recommended by the ICRP. An analytical solutions of the system of balance equations among the compartments were obtained using the Birchall's algorithm, and the urinary excretion function and the lung retention function of uranium were obtained. An initial or total intakes by intake modes were calculated by applying excretion and retention functions to the urinary uranium concentration and the lung burden measured with a lung counter. The dose coefficients given in ICRP 78 are used to estimate the committed effective doses from the calculated intakes.

Enzyme activity changes by intraperitoneal injection of uranium in the carp liver (우라늄 투여후 간조직에서의 효소활성도의 변화)

  • Kim, In-Gyu;Kim, Kug-Chan;Kim, Jin-Kyu;Kim, Sang-Bok;Chun, Ki-Chung;Park, Hyo-Kook;Lee, Kang-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.61-69
    • /
    • 1993
  • We examined various enzyme activity changes by intraperitoneal injection uranium in the carp liver. These enzyme activity changes can be used as biochemical indicators of internal exposure to uranium. The results were followings ; 1) Total protein concentration decreased by intraperitoneal injection in the carp liver. 2) Lysosomal acid pretense and ${\beta}-glucuronidase$ activities increased in the liver until sixth intraperitoneal injection of uranium, but Lysosomal acid phosphatase activities decreased in the liver until the sixth injection of uranium. 3) Alkaline phosphatase activities sharply increased and Glutamate oxaloacetate Transaminase activities steadily decreased in the liver until the sixth injection of uranium. 4) Creatine %kinase activities steadily decreased and malate dehydrogenase activities sharply decreased in the liver after the primary injection of uranium. Any malate dehydrogenase activities was not detected after sixth injection of uranium.

  • PDF

The Measurement of Airborne Radon Daughter Concentrations in the Atmosphere (대기중(大氣中) 라돈 붕괴생성물(崩壞生成物)의 공기중(空氣中) 방사능(放射能) 농도(濃度)의 측정(測定))

  • Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.5-13
    • /
    • 1979
  • A simple method for determining the airborne concentration of radon daughter products has been developed, which is based on gross alpha counting of the air filter collections at several time intervals after completion of air sampling. The concentration of each nuclide is then obtained from an equation involving the alpha disintegrations, the sampling time, and the known numerical coefficients. The state of radioactive disequilibrium is also investigated. The atmosphere sampled in the TRIGA Mark-III reactor room was largely in disequilibrium. The extent of radioactive disequilibrium between radon daughter products seems likely depend on sampling times associated with turbulence conditions. The data obtained here will certainly provide useful information on the evaluation of internal exposure and calibration of effluent monitoring instruments.

  • PDF

Calculation of Internal Exposure Dose in Korean Man Resulting from Single and Chronic Intake of Tritium (트리튬($^{3}H$)의 단일(單一) 및 만성섭취(晩性攝取)에 대한 한국인(韓國人)의 내부피복(內部被曝) 선량(線量) 계산(計算))

  • Kim, Jang-Lyul;Yook, Chong-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.2
    • /
    • pp.8-14
    • /
    • 1983
  • The doses to Korean adult by a single and chronic intake of tritiated water are determined using a three compartment model, which describes the retention of tritium radionuclide in body water and in bound organic form in the body. The results show that the total dose of a single intake, using retention half-time for the three-compartment of 9, 30, and 450 days, is 17.64 mrads ($176.4{\mu}Gy$) per 1mCi/kg ($3.7{\times}10^7Bq/kg$) intake, 97% of which is due to tritium in body water and 3% to bound tritium in tissue. In the chronic intake of 1mCi/day($3.7{\times}10^7Bq/day$) tritiated water, the total dose is 85.5 mrad/day(0.855mGy/day). Furthermore, in this study (MPC) a and (MPC)w values of tritium for Korean man are calculated by using the modified formula originated from ICRP Publication-2. From the results, we found that the (MPC) a, w values of ICRP underestimated approximately 50%, the (MPC)a, w values of Korean man must be elevated as high as approximately 50% than that of ICRP.

  • PDF

Nootkatol prevents ultraviolet radiation-induced photoaging via ORAI1 and TRPV1 inhibition in melanocytes and keratinocytes

  • Woo, Joo Han;Nam, Da Yeong;Kim, Hyun Jong;Hong, Phan Thi Lam;Kim, Woo Kyung;Nam, Joo Hyun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.1
    • /
    • pp.87-94
    • /
    • 2021
  • Skin photoaging occurs due to chronic exposure to solar ultraviolet radiation (UV), the main factor contributing to extrinsic skin aging. Clinical signs of photoaging include the formation of deep, coarse skin wrinkles and hyperpigmentation. Although melanogenesis and skin wrinkling occur in different skin cells and have different underlying mechanisms, their initiation involves intracellular calcium signaling via calcium ion channels. The ORAI1 channel initiates melanogenesis in melanocytes, and the TRPV1 channel initiates MMP-1 production in keratinocytes in response to UV stimulation. We aimed to develop a drug that may simultaneously inhibit ORAI1 and TRPV1 activity to help prevent photoaging. We synthesized nootkatol, a chemical derivative of valencene. TRPV1 and ORAI1 activities were measured using the whole-cell patch-clamp technique. Intracellular calcium concentration [Ca2+]i was measured using calcium-sensitive fluorescent dye (Fura-2 AM). UV-induced melanin formation and MMP-1 production were quantified in B16F10 melanoma cells and HaCaT cells, respectively. Our results indicate that nootkatol (90 μM) reduced TRPV1 current by 94% ± 2% at -60 mV and ORAI1 current by 97% ± 1% at -120 mV. Intracellular calcium signaling was significantly inhibited by nootkatol in response to ORAI1 activation in human primary melanocytes (51.6% ± 0.98% at 100 μM). Additionally, UV-induced melanin synthesis was reduced by 76.38% ± 5.90% in B16F10 melanoma cells, and UV-induced MMP-1 production was reduced by 59.33% ± 1.49% in HaCaT cells. In conclusion, nootkatol inhibits both TRPV1 and ORAI1 to prevent photoaging, and targeting ion channels may be a promising strategy for preventing photoaging.

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

DISTRIBUTION OF ABSORBED DOSES TO THE IMPORTANT ORGANS OF HEAD AND NECK REGION IN PANORAMIC RADIOGRAPHY (파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포)

  • Kim Byeong Sam;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.253-264
    • /
    • 1990
  • The purpose of this study was to estimate the distribution of absorbed doses of each important organs of head and neck region in panoramic radiography. Radiation dosimetry at internal anatomic sites and skin surfaces of phantom (RT-210 Humanoid Head & Neck Section/sup R/) was performed with lithium fluoride (TLD-100/sup R/) thermoluminescent dosimeters according to change of kilovoltage (65kVp, 75kVp and 85kVp) with 4 miliamperage and 20 second exposure time. The results obtained were as follows; Radiation absorbed doses of internal anatomic sites were presented the highest doses of 1.04 mGy, 1.065 mGy and 2.09 mGy in nasopharynx, relatively high doses of 0.525 mGy, 0.59 mGy and 1.108 mGy in deep lobe of parotid gland, 0.481 mGy, 0.68 mGy and 1.191 mGy in submandibular gland. But there were comparatively low doses of 0.172 mGy and 0.128 mGy in eyes and thyroid gland that absorbed dose was estimated at 85kVp. Radiation absorbed doses of skin surfaces were presented the highest doses of 1. 263 mGy, 1.538 mGy and 2.952 mGy in back side of first cervical vertebra and relatively high doses of 0.267 mGy, 0.401 mGy and 0.481 mGy in parotid gland. But there were comparatively low doses of 0.057 mGy, 0.068 mGy and 0.081 mGy in philtrum and 0.059 mGy in middle portion of chin that absorbed dose was estimated at 85kVp. According to increase of kilovoltage, the radiation absorbed doses were increased 1.1 times when kilovolt age changes from 65kVp to 75kVp and 1.9 times when kilovolt age changes from 75kVp to 85kVp at internal anatomic sites. According to increase of kilovoltage, the radiation absorbed doses were increased 1.3 times when kilovolt age changes from 65kVp to 75kVp and 1.6 times when kilovoltage changes from 75kVp to 85kVp at skin surfaces.

  • PDF