• Title/Summary/Keyword: internal parameter

Search Result 528, Processing Time 0.025 seconds

Semi-automatic Camera Calibration Using Quaternions (쿼터니언을 이용한 반자동 카메라 캘리브레이션)

  • Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.2
    • /
    • pp.43-50
    • /
    • 2018
  • The camera is a key element in image-based three-dimensional positioning, and camera calibration, which properly determines the internal characteristics of such a camera, is a necessary process that must be preceded in order to determine the three-dimensional coordinates of the object. In this study, a new methodology was proposed to determine interior orientation parameters of a camera semi-automatically without being influenced by size and shape of checkerboard for camera calibration. The proposed method consists of exterior orientation parameters estimation using quaternion, recognition of calibration target, and interior orientation parameter determination through bundle block adjustment. After determining the interior orientation parameters using the chessboard calibration target, the three-dimensional position of the small 3D model was determined. In addition, the horizontal and vertical position errors were about ${\pm}0.006m$ and ${\pm}0.007m$, respectively, through the accuracy evaluation using the checkpoints.

The Study on the Fire Resistance Performance of the CFT (Concrete filled Tube) Column According to the Concrete Compressive Strength and Load Ratio (콘크리트 압축강도 및 하중비에 따른 CFT기둥의 내화성능에 관한 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.44-51
    • /
    • 2010
  • This study, to develop the technology of the fire resistance design of CFT structure based on fire resistance performance design, was suppose to use as basic data for performance design through a measure of temperature and deformation of the CFT specimen as parameter is the concrete compressive strength and load ratio. In accordance with KS F 2257-1 and 7, 24 MPa and 40 MPa and the load ratio of 0.9, 0.6 and 0.2 were imposed on a square column and as a result of evaluating in accordance with the fire resistance criteria, in case of 24 MPa, the fire resistance performance was improved by 73 minutes when the load ratio was reduced by 0.3. And when it comes to 40 MPa, the fire resistance was 31 minutes and 180 minutes when a load ratio was 0.6 and 0.2, respectively. As a result of evaluating fire resistant performance depending on variation of internal concrete strength, it proved that the higher the strength the lower the fire resistance.

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.274-282
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.

Estimation Formula for Shear Strength of RCS Beam-Column Joint (RCS 보-기둥 접합부의 전단강도 산정식 평가)

  • Chang, Kug-Kwan;Jeon, Choong-Geun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.1-9
    • /
    • 2015
  • This study is on the shear strength of the internal joints of RCS composite structure consisting of reinforced concrete column and steel beam. As a newly structure system, the composite system has been developed to fully utilize the advantages of reinforced concrete column and steel beam, which also include economic and practical joint detail. Nevertheless stress transfer mechanism and structural behavior of the joints had not been still clearly revealed and shown much difference from the proposed equation. In this study, by observing the crossing of reinforced concrete column through steel beam to the RCS structure beam type, thirty seven shear failure specimens were selected and applied to the 5 major equations which is used to calculate the shear strength of RCS joint. Through the regression analysis, modified equation which is more reliable and approximate results for shear strength of RCS joints was proposed.

Effect of the factor developing the Heat of Hydration on Durability Design in the Subway Concrete Structure (수화열 발생인자가 지하철 콘크리트 구조물의 내구설계에 미치는 영향)

  • Lim Young-Su;Kim Eun Kyum;Sung Ki Han
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1131-1137
    • /
    • 2004
  • With the recent continuous expansion of subways, newly created subways tend to have lower locations and wider sections. Furthermore. since box structures and evacuating tunnels are classified into a category of mass-concrete. the thermal-stress, emitted from the inside. causes cracks to structures from the inception of constructing. In this paper, thermal-stress analysis and durability evaluation of box structure were carried out to investigate relationship between durability and parameter causing the heat of hydration. Through the examination, this paper tries to find out satisfactory solutions to regulated thermal crack and ensure the required duration period. The results of this paper showed that to control thermal crack and guarantee the required duration period it was more effective to use low-heat-portland cement and moderateheat-portland cement. As cement volume due to reduction of water-cement ratio increased, the possibility of thermal cracks occurrence increased but results of durability evaluation was different depending on evaluation method. The results showed that the appropriate water-cement ratio to control the heat of hydration and satisfy the required durability was $45\∼55\%$. And it was showed that during placement of concrete blocks ambient temperature affect the heat of hydration. thermal crack and long-term durability largely and when concrete was placed at low temperature to control thermal crack. it need to try to guarantee the required duration period. Henceforth, by studying not only internal and external conditions, such as the relative humidity and the unit weight. but also methods, to evaluate durability, in accordance with domestic situations, more reasonable design of durability should be achieved.

  • PDF

Effects on n-Alcohols on the Amino-Proton Chemical Shifts and on the Hindered Rotation about the N-C(O) Bond of Acetamide (아세트아미드의 아미노 양성자의 화학적 이동과 N-C(O) 결합주위의 부자유회전에 미치는 n-알코올 용매 효과)

  • Gwon, Sun Gi;Choe, Jong Ho;Choe, Yeong Sang;Yun, Chang Ju;Gwon, Dae Geun
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.509-516
    • /
    • 1990
  • 1H-nmr chemical shifts and lineshapes of amino-protons of acetamide (AA) in n-alcohols were determined. The chemical shifts are discussed by the Reichardt's solvent polarity parameter, E$_{T}$(30). The following relationship between $\delta$obs and E$_{T}$(30) was obtained. ${\delta}_{obs}$ = ${\delta}_{o}$ + aE$_{T}$ (30) + b[E$_{T}$(30)]$^2$ where ${\delta}_{o}$ is the chemical shift of the solute in gaseous state or at $E_{T}$(30) = 0, a is a characteristic constant for the protons of AA in n-alcohol solutions and b is a constant for the solute (AA)-solvent (n-alcohols) interaction. The barrier of the hindered rotation about the N-C(O) bond in AA was obtained by analysis of the lineshapes of the amino-protons in AA. The behavior of the internal rotation as well as chemical shifts of the amino-protons in AA has been found to be closely related to the $E_{T}$(30) of n-alcohols.

  • PDF

The Classification of Arrhythmia Using Similarity Analysis Between Unit Patterns at ECG Signal (ECG 신호에서 단위패턴간 유사도분석을 이용한 부정맥 분류 알고리즘)

  • Bae, Jung-Hyoun;Lim, Seung-Ju;Kim, Jeong-Ju;Park, Sung-Dae;Kim, Jeong-Do
    • The KIPS Transactions:PartD
    • /
    • v.19D no.1
    • /
    • pp.105-112
    • /
    • 2012
  • Most methods for detecting PVC and APC require the measurement of accurate QRS complex, P wave and T wave. In this study, we propose new algorithm for detecting PVC and APC without using complex parameter and algorithms. Proposed algorithm have wide applicability to abnormal waveform by personal distinction and difference as well as all sorts of normal waveform on ECG. To achieve this, we separate ECG signal into each unit patterns and made a standard unit pattern by just using unit patterns which have normal R-R internal. After that, we detect PVC and APC by using similarity analysis for pattern matching between standard unit pattern and each unit patterns.

Method for Determination of Maximum Allowable Pressure of Pressure Vessel Considering Detonation (폭굉을 고려한 압력용기 최대허용압력 결정방법의 제안)

  • Choi, Jinbok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.235-241
    • /
    • 2018
  • The internal pressure is a critical parameter for designing a pressure vessel. The static pressure that a pressure vessel must withstand is usually determined according to the various codes and standards with simple formula or numerical simulations considering the geometric parameters such as diameter and thickness of a vessel. However, there is no specific codes or technical standards we can use practically for designing of pressure vessels which have to endure the detonation pressure. Detonation pressure is a kind of dynamic pressure which causes an impulsive pressure on the vessel wall in a extremely short time duration. In addition, it is known that the magnitude of reflected pressure at the vessel wall due to the explosion can be over twice the incident pressure. Therefore, if we only consider the reflected pressure, the design of the pressure vessel can be too conservative from the economical point of view. In this study, we suggest a practical method to evaluate the magnitude of maximum allowable pressure that the pressure vessel can withstand against the detonation inside a vessel. As an example to validate the proposed method, we consider the pressure vessel containing hydrogen gas.

Transbilayer Effects of Chlorpromazine.HCl on Rotational Mobility of Synaptosomal Plasma Membrane Vesicles Isolated from Bovine Brain

  • Ahn, Ki-Weon;Choi, Chang-Hwa;Kim, Inn-Se;Chung, In-Kyo;Cho, Goon-Jae;Jang, Hye-Ock;Yun, Il
    • BMB Reports
    • /
    • v.33 no.6
    • /
    • pp.541-547
    • /
    • 2000
  • Fluorescence polarization of 1,6-diphenyl-1,3,5-hexatriene (DPH) was used to evaluate the effects of chlorpromazine HCl on the range of the rotational mobility of bulk bilayer structure of the synaptosomal plasma membrane vesicles (SPMV) isolated from a bovine brain. In a dose-dependent manner, chlorpromazine HCl increased the anisotropy (r), limiting anisotropy ($r_{\infty}$) and order parameter (S) of DPH in the membranes. Cationic 1-[4-(trimethylammonio)-phenyl]-6-phenylhexa-1,3,5-hexatriene (TMA-DPH) and anionic 3-[p-(6-phenyl)-1,3,5-hexatrienyl]-phenylpropionic acid (PRO-DPH) were utilized to examine the range of transbilayer asymmetric rotational mobility of the neuronal membranes. The anisotropy (r) of TMA-DPH in the inner monolayer was 0.034 greater than the value of PRO-DPH in the outer monolayer of the membranes. Both cationic TMA-DPH and anionic PRO-DPH were also used to examine the transbilayer asymmetric effects of chlorpromazine HCl on the range of rotational mobility of the membranes. Chlorpromazine HCl have a decreasing effects on the rotational mobility of the bulk bilayer structures and have a greater decreasing effect on the mobility of the inner monolayer as compared to the outer monolayer of the membranes. It has been proven that chlorpromazine HCl exhibit a selective rather than nonselective fluidizing effect within the transbilayer domains of the SPMV.

  • PDF

A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging (전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구)

  • 윤성익;권수일;추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.105-113
    • /
    • 1998
  • Accurate radiation dosimetric characters is very important to determine of dose to a radiotherapeutic patient. Medical linear accelerators have been developed not only its new quality of convenient operation but also electric moderation. It is reliable to measure more detail physical parameter that linac's internal ability. Typically, radiation dosimetric tool is classified ionization chamber, film, thermoluminescence dosimeter, etc. Nowaday, Electronic Portal Imaging Device is smeared in radiation field to verification of treatment region. EPID's image was focused that using both on-line image verification and absolutely minimum absorbed dose during radiotherapy. So, Electronic Portal Imaging was tested for quality evaluation of medical linear accelerator had its pure conditional flash. This study has performed symmetry, Light/Radiation field congruence, and energy check, geometry difference on wedge filter using a liquid filled ion chamber (EPID). Prior to irradiated on EPID, high energy photon beam is checked with ion chamber. Using these results more convenient dosimetric method is accomplished by EPID that taken digital image. Medical image is acquired with EPID too. Therefore, EPID can be analyzed by numerical information for what want to see or get more knowledge for natural human condition.

  • PDF