• 제목/요약/키워드: internal micro grooves

검색결과 5건 처리시간 0.019초

Effect of Micro Grooves on the Performance of Condensing Heat Transfer of the Micro Grooved Thermosyphons

  • Han, Kyu-Il;Cho, Dong-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.184-191
    • /
    • 2002
  • This study concerns the performance of the condensing heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal micro grooves. Distilled water, methanol, ethanol have been used as the working fluid. The numbers of grooves and operating temperature have been investigated as the experimental parameters. Condensing heat transfer coefficients and heat flux are obtained from experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, numbers of grooves are very important factors for the operation of thermosyphons. The working fluid with high latent heat such as water has a good heat transfer rate compared to methanol and ethanol. The relatively high rate of heat transfer is achieved when the thermosyphon with internal micro grooves is used compared to that with plain tube. Condensing heat transfer coefficient of grooved thermosyphon is 1.5∼2 times higher in methanol and 1.3∼l.5 times higher in ethanol compared to plain tube. The best condensation heat transfer performance is obtained for 60 grooves, and the maximum value of this case is 2.5 times higher than that of the plain tube.

나선코일의 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics of Helical Coiled Tube)

  • 박종운;조동현
    • 수산해양교육연구
    • /
    • 제16권2호
    • /
    • pp.257-270
    • /
    • 2004
  • The two-phase closed thermosyphon is a heat transfer device capable of transfer large quantities of heat from a source to a sink by taking advantage of the high heat transfer rates associated with the evaporation and condensation of a working fluid within the device. A study was carried out with the performance of the heat transfer of the thermosyphon having 50, 60, 70, 80, 90 internal micro grooves in which boiling and condensation occur. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphon is also tested for comparison. Water, methanol and ethanol have been used as the working fluids. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon, the inclination angle, micro grooves and operating temperature have been used as the experimental parameters. The heat flux and the boiling and the condensation heat transfer coefficient and overall heat transfer coefficient at the condenser and evaporator zone are estimated from the experimental results. The experimental results have been assessed and compared with existing correlations. Imura's and Kusuda's correlation for boiling showed in good agreement with experimental results within ${\pm}20$% in plain thermosyphon. The maximum heat transfer rate was obtained when the liquid fill ratio was about 25%. The high heat transfer coefficient was found between 25o and 30o of inclination angle for water and between 20o and 25o for methanol and ethanol. The relatively high rates of heat transfer have been achieved in the thermosyphon with internal micro grooves. The micro grooved thermosyphon having 60 grooves shows the best heat transfer coefficient in both condensation and boiling. The maximum enhancement (i.e. the ratio of the heat transfer coefficients of the micro grooved thermosyphon to plain thermosyphon) is 2.5 for condensation and 2.3 for boiling.

경사 열사이폰 열교환기의 비등열전달 성능에 관한 연구 (A Study on the Performance of Boiling Beat Transfer of Inclined Thermosyphon Heat Exchangers with Internal Grooves)

  • 조동현;이종선
    • 한국산학기술학회논문지
    • /
    • 제6권2호
    • /
    • pp.202-209
    • /
    • 2005
  • 경사 열사이폰 열교환기는 잠열을 이용한 대량의 열수송 능력과 증기류의 열확산에 의한 온도 분포의 균일화, 경량, 간단한 구조, 빠른 열응답 특성 등의 우수성을 가지고 있다. 본 연구에서는 이와 같은 우수성을 보유하고 있는 경사 열사이폰 열교환기에 대하여 경사각의 변화, 작동유체의 종류, 열유속 및 내부압력 등 열사이폰의 작동에 관련된 변수들에 관하여 열전달 성능을 실험적으로 연구하였다. 평관형 및 마이크로 그루브형 경사 열사이폰에서 실험적인 연구를 수행한 결과, 마이크로 60그루브형으로 경사각이 $30^{\circ}$이고 작동유체가 증류수인 경우 비등열전달계수는 $15000\;W/m^3K$으로 나타났으며, 이 간은 평관형 경사 열사이폰의 비등열전달계수보다 1.6배 정도 높게 나타났다. 그리고 작동유체가 증류수인 경우 평관형 열사이폰에서 비등열전달계수는 경사각이 $25^{\circ}{\sim}30^{\circ}$ 범위에서, 메탄올과 에탄올에서는 경사각이 $20^{\circ}{\sim}25^{\circ}$ 범위에서 최대 비등열전달계수를 나타났다. 또한 평관형 열사이폰은 경사각이 $25^{\circ}{\sim}30^{\circ}$범위에서, 마이크로 그루브형 열사이폰은 경사각이 $20^{\circ}{\sim}25^{\circ}$사이에서 최대 비등열전달 성능을 나타내었다.

  • PDF

마이크로 그루브를 가진 열사이폰 열교환기의 비등열전달 특성에 관한 연구 (A Study on the Characteristics of Boiling Heat Trausfer of Thermosyphon Heat Exchangers with Various Micro Grooves)

  • 조동현;이종선
    • 한국산학기술학회논문지
    • /
    • 제5권5호
    • /
    • pp.421-428
    • /
    • 2004
  • 열사이폰 열교환기는 잠열을 이용한 대량의 열수송 능력과 증기류의 열확산에 의한 온도 분포의 균일화, 경량, 간단한 구조, 빠른 열응답 특성 등의 우수성을 가지고 있다. 본 연구에서는 이와 같은 우수성을 보유하고 있는 열사이폰 열교환기에 대하여 기하학적 형태, 유체의 물성, 열유속 및 내부압력 등 열사이폰의 작동에 관련된 변수들에 관하여 열전달 성능을 실험적으로 연구하였다. 평관형 및 마이크로 그루브형 열사이폰에서 마이크로 그루브수의 변화와 작동유체는 증류수, 메탄올 및 에탄올의 종류 변화에 대한 실험적인 연구를 수행한 결과, 열전도계수와 증발 잠열값이 큰 증류수가 메탄올 및 에탄올보다 비등열전달계수가 높게 나타났다. 또한 마이크로 그루브형 열사이폰이 평관형 열사이폰보다 비등열전달계수가 높게 나타났으며 작동유체가 증류수인 경우 $2{\~}2.5$배 메탄올인 경우 $1.5{\~}2$배, 에탄올인 경우 $1.3{\~}1.5$배 높게 나타났다.

  • PDF

평활관 및 미세휜관 내에서의 물을 이용한 열전달 및 압력강하 특성에 관한 실험 (Experimental study of heat transfer and pressure drop characteristics for flow of water inside circular smooth and micro-fin tubes)

  • 박혁범;유승문;윤백;유국철
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.454-461
    • /
    • 1997
  • Heat transfer and pressure drop for single phase flow of water in circular smooth and micro-fin tubes are measured. Copper tubes of 9.52 and 7mm outer diameter were used. The internal roughness in micro-fin tubes was formed by spiral grooves having $25^{\circ}$ helx angle, 0. 12mm fin height and 0.454mm pitch in 9.52mm tubes; $18^{\circ}$ helix angle, 0.15mm fin height and 0.322mm pitch in 7mm tubes. The measured friction factor and heat transfer coefficient are compared with relevant previous works, and the correlations for micro-fin tube are developed.