• Title/Summary/Keyword: internal materials

Search Result 3,156, Processing Time 0.035 seconds

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.

Long-Term Clinical Effects of Carotid Intraplaque Neovascularization in Patients with Coronary Artery Disease

  • Hyemoon Chung;Bu Yong Kim;Hyun Soo Kim;Hyung Oh Kim;Jung Myung Lee;Jong Shin Woo;Jin Bae Kim;Woo-Shik Kim;Kwon Sam Kim;Weon Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.900-907
    • /
    • 2020
  • Objective: To investigate the predictive value of intraplaque neovascularization (IPN) for cardiovascular outcomes. Materials and Methods: We evaluated 217 patients with coronary artery disease (CAD) (158 men; mean age, 68 ± 10 years) with a maximal carotid plaque thickness ≥ 1.5 mm for the presence of IPN using contrast-enhanced ultrasonography. We compared patients with (n = 116) and without (n = 101) IPN during the follow-up period and investigated the predictors of major adverse cardiovascular events (MACE), including cardiac death, myocardial infarction, coronary artery revascularization, and transient ischemic accident/stroke. Results: During the mean follow-up period of 995 ± 610 days, the MACE rate was 6% (13/217). Patients with IPN had a higher maximal thickness than those without IPN (2.86 ± 1.01 vs. 2.61 ± 0.84 mm, p = 0.046). Common carotid artery-peak systolic velocity, left ventricular mass index (LVMI), and ventricular-vascular coupling index were significantly correlated with MACE. However, on multivariate Cox regression analysis, increased LVMI was independently related to MACE (p < 0.05). The presence of IPN could not predict MACE. Conclusion: The presence of IPN was related to a higher plaque thickness but could not predict cardiovascular outcomes better than conventional clinical factors in patients with CAD.

Effects of Process Parameters owl the Tube Hydroformability (하이드로포밍 성형성에 미치는 공정인자 영향도 해석)

  • 김봉준;김정운;문영훈
    • Transactions of Materials Processing
    • /
    • v.11 no.1
    • /
    • pp.54-60
    • /
    • 2002
  • The purpose of the present paper is to investigate the effect of Process parameters such as internal pressure, amount of axial feeding, and frictional condition between the die and the material on the tube hydro-formability. For carbon steel tubes(STKM 12A, STBH 410 and SPS 290), simple bulging, circular bulging and Tee-fitting tests are performed to evaluate the hydro-formability of these materials which is determined by deformation characteristics such as thickness distribution, forming height and branch dome shape. The formabilities obtained from these tests are analysed and compared with the results of the numerical simulation.

Effect of specific gravity and annual ring width on the acoustical properties of European lumber used in violin making (유럽산 바이올린 용재의 비중과 년륜폭이 소재의 음향적 성질에 미치는 영향)

  • 정우양;홍병화
    • Journal of the Korea Furniture Society
    • /
    • v.10 no.1
    • /
    • pp.57-63
    • /
    • 1999
  • This study was carried out to analyze the relationship between basic physical properties and acoustical characteristics of imported violin wood and to offer the information on raw material procurement and incoming-material quality control to domestic violin makers which have purchased most raw materials from European exporting countries at high expense. Equilibrium moisture content of European spruce with lower specific gravity after the prolonged storage was rather higher than that of European maple with higher specific gravity. The specific gravity of spruce increased with decreasing annual ring width, however, that of narrower annual ring. Increasement in specific gravity enhanced the dynamic Young's modulus of both wood species, but influenced the vibration energy loss by internal friction differently between two species. For dynamic MOE, qurater-sawn spruce was higher than the flat-sawn, but maple showed the reverse directional characteristics. Consequently, it would be well for violin makers to establish the standard for materials and quality control system to assure the quality of their violin products.

  • PDF

Non-Linear Fracture Mechanics Analyses for Axial Semi-Elliptical Surface Cracked Pipes (배관 내 축방향 반타원 표면균열에 대한 비선형 파괴역학 해석)

  • Kim, Jin-Su;Kim, Yun-Jae;Kim, Young-Jin
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.143-148
    • /
    • 2003
  • This paper provides two types of engineering J estimation equations for cylinders with finite internal axial surface cracks under internal pressure. The first type is the so-called GE/EPRI type J estimation equation based on Ramberg-Osgood materials. Based on detailed 3-D FE results the GE/EPRI-type J estimation equation along the crack front is proposed and validated for Ramberg-Osgood materials. For more general application, the developed GE/EPRI-type solutions are then re-formulated based on the reference stress concept. The proposed reference stress based J estimation equation has good agreement between the FE results and the proposed reference stress based J estimation provides confidence in the use of the proposed method for elastic-plastic fracture mechanics of pressurised piping

  • PDF

APPLICATION OF FIBRIN ADHESIVE IN DISK REPLACEMENT AFTER MENISCECTOMY (관절원판 절제술후 중간삽입물 고정에 피브린 접착제의 응용)

  • Chung, Hoon;Kim, Hyeong-Keun;Kim, Young-Soo;Yu, Ki-Jun;Ahn, Byoung-Guen
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.3
    • /
    • pp.175-184
    • /
    • 1992
  • Meniscectomy is indicated for the internal derangement of disk with perforation and gross morphological changes, nonreactive to conservative treatment procedures. After the meniscectomy, permanent disk replacement can be followed. Variable materials have been introduced for disk replacement. Of them, relatively harder replacing materials should have been fixed with surgical wire only. This poor fixation method provide inadequate retentive force and conclusively can be attributed to postoperative noise, poor prognosis. We tried to use biocompatible fibrin adhesive in order to obtain additional fixation force in the method above mentioned and treated two patients with the late stage of internal derangement of disk In both cases, satisfactory results were obtained.

  • PDF

A Development of Manufacturing Process of Wooden Footpath Block to Reuse of Wood Waste (목질폐잔재를 재활용한 목질보도블록 제조기술 개발)

  • Park, Hee-Jun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.96-104
    • /
    • 1997
  • The objective of this research project was to develop the wooden footpath block to reuse of wood waste. Some physical and mechanical properties of the wooden block such as water absorption, thickness swelling, modulus of rupture, internal bond, density profile and impact resistance were studied. Water absorption and thickness swelling of the wooden block were greatly reduced when the wooden block was pressed inside the forming device than by conventional hot pressing. Also, Modulus of rupture and internal bond of the wooden block were increased greatly when the pressing was completed inside the forming device. The density profile of the wooden block was improved up to 93.5%, minimum to average density ratio. The wooden block manufactured in this study have excellent physical and mechanical prperties in comparison with existing wood based materials. So, these wooden blocks are applicable to footpth block or other exterior members.

  • PDF

Basic Research on 3D Cultural Heritage Packaging Technology Using Thermoplastic Polyurethane Elastomers

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.37 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • This study investigated mechanical property changes by measuring compression factors, resilience, and compressive strength according to packaging pattern and filling rate to identify the applicability of cultural heritage packaging using thermoplastic polyurethane elastomers (TPU). Research results indicate that the cross-shaped 3D pattern showed the best resilience when the internal filling rate was 20%, while the octet pattern was the best when the filling rate was either 40 and 60%. The octet pattern had the best mechanical properties and stability with resistance capacities of 20.79 kgf/cm2, 40.40 kgf/cm2, and 82.23 kgf/cm2 at 38%, 39%, and 40% recovery speeds, respectively, depending on the internal filling rate (20, 40, 60%). Based on these results, basic data on the applicability, stability, and reliability of 3D cultural heritage packaging materials using TPU materials were obtained.

A strategy to prepare internally plasticized PVC using a castor oil based derivative

  • Chu, Hongying;Ma, Jinju
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.11
    • /
    • pp.2296-2302
    • /
    • 2018
  • Internally plasticized PVC was prepared via chemical reaction of azide PVC and alkynyl group containing castor oil methyl ester. The chemical structure of alkynyl group containing castor oil methyl ester and internally plasticized PVC was characterized with FT-IR and $^1H$ NMR. Properties of internally plasticized PVC, including thermal stability, tensile tests and resistance to extraction in different solvents, was investigated. The results showed that alkynyl group containing castor oil methyl ester, as internal plasticizer of PVC, not only decreased the $T_g$ of PVC from $84.6^{\circ}C$ to $41.6^{\circ}C$ efficiently, but also presented no plasticizer loss in five different solvents. The tensile tests showed that elongation at break and tensile strength of internally plasticized PVC was 353.8% and 18.1 MPa. The internally plasticized PVC has potential application in replacing the traditional PVC material in PVC products with high durability.

Manufacturing of High-Performance Double Layered Tube with Corrugated Internal Pattern via the Hydroforming Process (액압 성형을 이용한 내부복합파형 고효율 이중관 제조 기술)

  • Han, S. W.;Kim, D. Y.;Moon, Y. H.
    • Transactions of Materials Processing
    • /
    • v.31 no.3
    • /
    • pp.143-150
    • /
    • 2022
  • The purpose of this study was to investigate an innovative hydroforming process for the cost-effective manufacturing of double layered tube with circumferentially corrugated patterns. Conventional double pipe heat exchanger has relatively poor heat transfer efficiency because of the limited contact area resulting from the concentrically arranged simple cylindrical structure. As a promising alternative to enhance heat transfer efficiency, double layered tube with corrugated internal pattern was considered in this study. To fabricate corrugated inner tube, innovative tube hydroforming system was developed. The customized loading paths were established using the simulated forming pressure and contracting stroke at various bar diameters. Experimentally obtained cross-sectional profiles were analyzed to evaluate the reliability and applicability of the hydroformed tube with various patterns. The results demonstrate that the proposed hydroforming process can be a feasible alternative for manufacturing high-performance double-tube heat exchangers.