• Title/Summary/Keyword: internal kinematics

Search Result 60, Processing Time 0.024 seconds

REVIEW OF COMPUTATIONAL MODELS FOR FOOTWEAR DESIGN AND EVALUATION (신발 설계 및 평가를 위한 컴퓨터 모델)

  • Cheung, Jason Tak-Man;Yu, Jia;Zhang, Ming
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.13-25
    • /
    • 2009
  • Existing footwear biomechanics studies rely on simplified kinetics and kinematics, plantar pressure and muscle electromyography measurements. Because of the complexity of foot-shoe interface and individualized subject response with different footwear, consistent results regarding the biomechanical performance of footwear or footwear components can yet be achieved. The computational approach can be an efficient and economic alternative to study the biomechanical interactions of foot and footwear. Continuous advancement in numerical techniques as well as computer technology has made the finite element method a versatile and successful tool for biomechanics researchdue to its capability of modelling irregular geometrical structures, complex material properties, and complicated loading and boundary conditions. Finite element analysis offers asystematic and economic alternative in search of more in-depth biomechanical information such as the internal stress and strain distributions of foot and footwear structures. In this paper, the current establishments and applications of the computational approach for footwear design and evaluation are reviewed.

Development of Telerobotic Surgery System with Single-Master Multi-Slave (단일마스터 멀티슬레이브형 텔레로보틱스 수술시스템 개발)

  • Hwang, Gil-Gueng;Jin, Tae-Seok;Hashimoto, Hedeki
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.918-925
    • /
    • 2006
  • Medical robotics and computer aided surgery in general, and robotic telesurgery in particular, are promising applications of robotics. In this paper, we shows a novel single-master (PHANTOM based single-master multi-slave telerobotic system) multi-slave system using two parallel mechanism micromanipulators as a slave device. After a general introduction to the systems structure and configuration of telerobotic system, a manipulation control strategy to build the system that human and both manipulators perform the cooperative manipulation, is introduced, followed by its kinematic analysis, mapping method, and experimental results.

The Relationship Between the Range of Hip Rotation and the Quadriceps Angle in Subjects With and Without Flat Foot

  • Lee, Keun-hyo;Chon, Seung-chul
    • Physical Therapy Korea
    • /
    • v.25 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • Background: Alignment of the lower limb is an important factor, influencing balance and gait in kinematics and kinetics, in patients with and without a flat arched foot. Flat arched foot are associated with the range of motion (ROM) of the hip and alignments of the knee joints, is strongly influenced. Objects: The purpose of this research was to investigate the relationship between hip joint ROM and quadriceps angle (Q-angle), by dividing them into two groups according to the presence or absence of flat feet, using a navicular drop test (NDT) and resting calcaneal stance position (RCSP). Methods: Forty elderly patients were allocated to the experimental group (flat foot group, n1=20) or the control group (non-flat group, n2=20). Universal and digital goniometer, tractograph and tape measure were used to determine the related changes in the hip ROM, Q-angle, NDT and RCSP. Results: Data were analyzed using the Pearson correlation coefficients. Active internal ROM of the hip joint (right, r=.803, p<.001), (left, r=.951, p<.001) were highly correlated with NDT, and also, was moderately correlated with Q-angle (right, r=.562, p=.019), (left, r=.757, p<.001). Passive internal ROM of the hip joint (right, r=.742, p=.001), (left, r=.922, p<.001) were highly correlated with NDT, and also, was moderately correlated with RCSP (right, r=-.530, p=.029) and with Q-angle (right, r=.710, p=.001), (left, r=.698, p=.002) in the flat foot group. However, no strong correlation among the hip ROM, NDT, RCSP and Q-angle were found in the non-flat foot group. Conclusion: This research may provide evidence of the correlations between hip internal ROM and flat foot.

KNEE: Basic Science and Injury of Bone (슬관절 주위 글격의 기초과학 및 스포츠 손상)

  • Kim Hee-Chun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.77-81
    • /
    • 2003
  • Purpose: The biomechanics and kinematics of knee joint were reviewed in this article. And then the common sports injuries were presented. Anatomy and Kinetics: None of the pairs of bearing surfaces in the knee joint is exactly congruent This allows the knee six degrees of freedom of motion. Tibiofemoral Kinematics: In flexion and extension, the axis of motion is not perpendicular to the medial-lateral plane of the joint, nor is it perpendicular to the axis of longitudinal rotation. This results in coupled varus angulation and internal rotation with flexion and in valgus angulation and external rotation with extension. Patellofemoral Articulation: Loads across the patellofemoral joint are indirectly related to the angle of knee flexion and directly related to the force generated within the quadriceps mechanism. Fractures of the Patella: Nonoperative treatment is indicated if the extensor mechanism is intact and if displacement of fragment is minimal. The specific type of internal fixation depends on the fracture pattern. It is important to repair retinaculum. Acute and Recurrent Patellar Instability: The degree of dysplasia and the extent of the instability play a large part in determining the success of nonoperative treatment. Patients who experience recurrent dislocations and patients with major anatomic variations require surgery to minimize their instability. Sports Injuries in School-age Atheletes: Patellar pain in young athletes groups a number of conditions, including Idiopathic Adolescent Anterior Knee Pain, Osgood- Schlatter Disease, and Sinding-Larsen-Johansson Disease.

  • PDF

Effects of Knee Brace on the Anterior Cruciate Ligament Injury Risk Factors during Spike Take Off in Female Volleyball Players (여자 배구 선수들의 스파이크 도약 시 무릎보호대가 전방십자인대 부상위험 요인에 미치는 영향)

  • Yang, Chang-Soo;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • In volleyball, the most common injuries are anterior cruciate ligament (ACL) tears. For this reason, volleyball players frequently use knee brace as prophylactic and rehabilitation measures. The purpose of the study was to investigate the effects of knee brace on anterior cruciate ligament injuries risk factors during spike take off in female volleyball players. Fifteen female volleyball players were recruited and performed randomly spike take off with and without knee brace. Kinematics and ground reaction data were collected to estimate the anterior cruciate ligament injuries risk factors. The ACL risk factors are knee maximum flexion angle, thigh maximum adduction angle, thigh maximum internal rotation angle, shank maximum abduction angle, shank maximum external rotation angle, knee maximum extension moment and knee maximum abduction moment. Data were analyzed with paired samples t-test with Bonfferoni collection. Female volleyball players with knee brace had no significant results in knee maximum flexion angle, thigh maximum adduction angle, thigh maximum internal rotation angle, shank maximum abduction angle and shank maximum external rotation angle compare to without knee brace. Female volleyball players, however, with knee brace showed more reduced knee maximum extension moment and knee maximal abduction moment than without knee brace. In conclusion, Female volleyball players with knee brace reduced anterior cruciate ligament stress.

Numerical Study on Designing Truncated Mooring Lines for FPSO Stability Analysis (FPSO 안정성 평가를 위한 절단계류선 모델링 수치 연구)

  • Kim, Yun-Ho;Cho, Seok-Kyu;Sung, Hong-Gun;Seo, Jang-Hoon;Suh, Yong-Suk
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.387-395
    • /
    • 2014
  • In this paper, a numerical analysis for an internal turret moored vessel located at a 400-m water depth is conducted. The target vessel has an internal turret that is located at the 0.2 Lpp position from the fore-side, with $3{\times}4$ complex mooring lines installed around the turret circumference. To investigate the motion response of the vessel and the structural reliability of the lines, model tests were conducted. The KRISO ocean basin has a water depth of 3.2 m, which represents 192m using a scaling of 1:60. In order to precisely represent the real-scale condition, equivalent mooring lines needed to be designed. Truncated mooring lines were designed to supplement the restriction of the flume's water depth and increase the reliability of the model testing. These truncated mooring lines were composed of two different chains in order to match the pre-tension, simultaneously restoring the curve and variation in the effective line tension. The static similarities were compared using a static pull-out test and free decaying test, and the dynamic similarities were matched via a regular wave test and combined environments test. Consequently, the designed truncated mooring system could represent the prototype mooring system relatively well in the aspects of kinematics and dynamics.

The Biomechancial Effects of an Interspinous Spacer Implant on 3-D Motions for the Treatment of Lumbar Spinal Stenosis (요추부 척추관 협착증 치료를 위한 극돌기간 삽입술의 3차원 분석을 통한 생체역학적 효과 분석)

  • 이희성;신규철;문수정;정태곤;이권용;이성재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1207-1210
    • /
    • 2004
  • As many humans age, degenerative lumbar spinal stenosis (DLSS) becomes a major cause of lower limb discomfort and disability. By surgical treatment method of DLSS, the existing surgical treatment methods using internal fixation have showed degeneration changes of an adjacent vertebrae and loss of lumbar spine lordosis-kyphosis due to eliminating a motion. For solving the problems of internal fixation, a novel interspinous spacer has been developed to treat DLSS by surgical treatment method. In this study, we evaluated the biomechanical effects of the interspinous spacer on the kinematics of the porcine lumbar spine before and after insertion of the implant. For this purpose, a device that is capable of measuring 3-D motions were built based on direct linear transformation (DLT) algorithm written with MATLAB program. Results showed that in extension, a change of the mean angle between the intact and the implanted specimens at L4-L5 was 1.87 degree difference and the implant reduced the extension range of motion of the L4-L5 (p&lt;0.05). But the range of motion in flexion, axial rotation and lateral bending at the adjacent segments was not statistically affected by the implant. In conclusion, we thought that interspinous spacer may have remedical value for DLSS by flexing human lumbar spine.

  • PDF

Internal kinematics of dwarf early-type galaxies with blue-center in the Virgo Cluster from Gemini GMOS long-slit spectroscopy

  • Chung, Jiwon;Rey, Soo-Chang;Sung, Eon-Chang;Lee, Youngdae;Kim, Suk;Lee, Woong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.33.1-33.1
    • /
    • 2016
  • Dwarf elliptical galaxies (dEs), the most abundant galaxy type in clusters, were recently shown to exhibit a wide variety in their properties. Particularly, the presence of blue cores in some dEs, what we call dE(bc), supports the scenario of late-type galaxy infall and subsequent transformation into red, quiescent dEs. While several transformation mechanisms for these dE(bc)s within cluster environment have been proposed, all these processes are able to explain only some of the observational properties of dEs. In this context, internal kinematic properties of dE(bc)s provide the most crucial evidence to discriminate different processes for the formation of these galaxies. We present Gemini Multi Object Spectrograph (GMOS) long-slit spectroscopy of two dE(bc)s in the Virgo cluster. We obtained radial profiles of velocity and velocity dispersion out to ~1.3 effective radius. We found that two dE(bc)s exhibit kinematically decoupled components as well as distinct peculiar features in velocity profiles, supporting the scenario of mergers. We also found that these galaxies are structurally compatible with low surface brightness component of blue compact dwarf galaxies. We suggest that a part of dE(bc)s in the Virgo Cluster were formed through galaxy merger in low density environment such as galaxy group or outskirt of the cluster, and then were quenched by subsequent effects within cluster environment.

  • PDF

Investigation of Target Echoes in Multi-static SONAR System - Part I : Design for Acoustic Measuring System (다중상태 소나시스템을 적용한 표적반향음 연구 - Part I : 측정시스템 설계)

  • Bae, Ho Seuk;Ji, Yoon Hee;Kim, Wan-Jin;Kim, Woo-Shik;Kim, Jea Soo;Yun, Sung-Ung
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.429-439
    • /
    • 2014
  • The target echoes contain information on the target such as the orientation, kinematics, and internal structure, as well as the external geometrical shape of the target. In addition, the pattern of the target echoes depends on the arrangement of the transmitters and receivers in space. Therefore, the study of the target echoes in a multi-static SONAR system can be useful for detecting and tracking submerged objects using an underwater surveillance system. For this purpose, an acoustic measuring system for multi-static target echoes was designed and tested in an acoustic water tank. Some preliminary data are presented and discussed.

Stellar and Ionized Gas Kinematics of Blue-cored Early-type Dwarf Galaxies in the Virgo Cluster

  • Chung, Jiwon;Rey, Soo-Chang;Kim, Suk;Lee, Youngdae;Lee, Woong;Sung, Eon-Chang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.49.3-50
    • /
    • 2015
  • Early-type dwarf galaxy (ETDG), the most abundant galaxy type in clusters, were recently shown to exhibit a wide variety in their properties. Particularly, the presence of blue cores in some ETDGs supports the scenario of late-type galaxy infall and subsequent transformation into red, quiescent ETDGs. While several transformation mechanisms for these ETDGs with blue core within cluster environment have been proposed, all these processes are able to explain only some of the observational properties of ETDGs such as stellar populations and structural parameters. In this context, internal kinematic properties of blue-cored ETDGs provide the most crucial evidence to discriminate different processes for the formation of these galaxies. We present a kinematic analysis of two blue-cored ETDGs in the Virgo cluster based on long-slit data obtained from Gemini Multi-Object Spectrographs (GMOS) observations. We find that the observed galaxies show kinematically decoupled sub-components in the velocity profile such as discontinuity or counter-rotating component. We discuss possible scenarios of formation of these transitional galaxies.

  • PDF