• Title/Summary/Keyword: internal heat source

Search Result 84, Processing Time 0.027 seconds

A Review of Recent Domestic Research on Herbal Medicine Treatments for Ulcerative Colitis: A Focus on OASIS Platform Research (궤양성 대장염의 한약치료에 대한 국내 연구동향 분석 - 오아시스 검색을 중심으로)

  • Sae-rom Choi;Ji-yoon Lee;Sang-min Park;Jae-wook Shin;Jee-hoon Baek;Min-ju Lee;Eun-jee Lee
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.6
    • /
    • pp.1256-1270
    • /
    • 2023
  • Objectives: This study analyzes domestic research trends on herbal medicine treatments for ulcerative colitis (UC) by examining 28 selected domestic papers using the Oriental Medicine Advanced Searching System (OASIS) as the main search source. Methods: A total of 28 domestic papers were selected on the OASIS platform as the main search source using the keywords "(궤양성 대장염) or (궤양성 대장병)" and "(한약) or (한의학)". Results: There were 11 case report studies and 17 case-control studies published from 2002 to 2022. All the case-control studies only dealt with mice and did not include human subjects. The most common pathologies were damp heat and Changpung. Hwangryunhaedok-tang was the most frequently prescribed herbal formula, and Coptidis Rhizoma was the most commonly used herb across all studies. The results showed that many studies demonstrated the significant effects of herbal treatment. Conclusion: Herbal medicine may exhibit therapeutic effects on various aspects of UC. However, evidence-based studies, such as clinical trials involving human subjects, are needed.

The Performance Improvement of a Gas Injection Heat Pump with a Flash Tank (기액분리기를 적용한 가스 인젝션 히트펌프의 성능 향상에 관한 실험적 연구)

  • Son, Kilsoo;Kim, Dongwoo;Choi, Sungkyung;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.297-305
    • /
    • 2017
  • Air-source heat pumps are widely used in residential heating systems. However, the decrease in the capacity of the heat pump is unavoidable when operating at very low and high ambient temperatures. The vapor injection technique is considered a promising technology to overcome this problem. Recent research on vapor injection cycles have mainly adopted a scroll compressor with an internal heat exchanger at severe operating conditions. This study measured the COP and EER of a gas injection heat pump using a flash tank with an inverter-driven rotary compressor at severe operating conditions. Compared to non-injection heat pumps, the heating capacity and COP of the gas injection heat pump improved up to 15% and 2.9%, respectively, at outdoor temperatures of $-10^{\circ}C$ to $7^{\circ}C$. The cooling capacity of the gas injection heat pump was 11% higher than the non-injection heat pump at an outdoor temperature of $35^{\circ}C$. At the same time, the EER of the gas injection heat pump was similar to that of the non-injection heat pump.

Fast Defect Detection of PCB using Ultrasound Thermography (초음파 서모그라피를 이용한 빠른 PCB 결함 검출)

  • Cho, Jai-Wan;Jung, Hyun-Kyu;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.273-275
    • /
    • 2005
  • Active thermography is being used since several years for remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements were performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

  • PDF

Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures (스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험)

  • Sim, Kyuho;Jeong, Min-Seong;Lee, Yoon-Pyo;Jang, Seon-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.

A Study on the Reduction of Diesel-Engine Emissions (디젤엔진 배기가스의 저감에 관한 연구)

  • Hur, Youn-Bok;Chung, Soon-Suk;Kim, Kwang-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.245-252
    • /
    • 2012
  • Internal engine is the main power source of vehicle and is the main source of air pollution. To satisfy this getting rigorous emission regulation, it must be solved simultaneously the dilemma of reducing emission gas and increasing heat efficiency. Diesel engine is preferred compare with gasoline engine in aspect of energy consumption but it must be solved reducing the containing of NOx, CO and HC. In this study 1. Looking for alternative of performance improvement of Exhaust Gas Recirculation(EGR) which is emission gas reduction system, 2. Reducing malfunction of controlling emission gas 3. Made possible precision control.

  • PDF

The Plan to Increase Efficiency of Exhaust Gas Recirculation System (배기가스 재순환장치 효율 증대 방안)

  • Kim, Kwang Soo;Chung, Soon Suk;Heo, Yun Bok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.185-194
    • /
    • 2014
  • Internal engine is the main power source of vehicle and is the main source of air pollution. To satisfy this getting rigorous emission regulation, it must be solved simultaneously the dilemma of reducing emission gas and increasing heat efficiency. Diesel engine is preferred compare with gasoline engine in aspect of energy consumption but it must be solved reducing the containing of NOx, CO and HC. In this study: 1. Looking for alternative of performance improvement of Exhaust Gas Recirculation(EGR) which is emission gas reduction system. 2. Reducing malfunction of controlling emission gas. 3. Made possible precision control.

Performance Characteristics Analysis of Gas Turbine-Pressurized SOFC Hybrid Systems (가스터빈-가압형 SOFC 하이브리드 시스템의 성능특성 해석)

  • 양원준;김동섭;김재환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.615-622
    • /
    • 2004
  • Recently, the hybrid system combining fuel cell and gas turbine has drawn much attention owing to its high efficiency and ultra low emission. It is now on the verge of world wide development and various system configurations have been proposed. A national project funded by Korean government has also been initiated to develop a pressurized hybrid system. This work aims at presenting design performance analysis for various possible system configurations as an initial step for the system development. Study focuses are given to major design options including the power ratio between gas turbine and fuel cell, reforming method (internal or external), reforming heat source (reforming burner, cathode hot air, fuel cell heat release) and steam supply method for reformer (anode gas recirculation, external steam generator). A wide variation in performance among different configurations has been predicted.

Modeling of Coking Process in a Coke Oven (코크스 공정에서의 열유동 현상 모델링)

  • Yang, Kwang-Heok;Yang, Won;Choi, Sang-Min
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1184-1189
    • /
    • 2004
  • Coking process is the thermal decomposition of bituminous coal with final temperature of about $900^{\circ}C$ Because coke plays important roles in ironmaking process in a blast furnace it's essential for developing modeling of coke oven. In this study, An unsteady 2-dimesional model is proposed to simulate coking process in a coke oven. In this model, gas and solid phase are assumed homogeneous continnum and solid bed is assumed as porous media . The model contains governing equations for the solid phase and the gas phase. Complicated phenomena such as swelling, softening, resolidification and shrinkage are neglected and mass loss by drying and devolatilization is reflected by generation of internal pores. Drying, devolatilization, heat transfer and generation of internal pores are also reflected in source terms. Calulated results are compared with experimental data

  • PDF

A study on the development of thermal environment prediction program in tunnel of the subway (지하철 터널내 열환경 예측 프로그램 개발에 관한 연구)

  • Kim, J.R.;Kim, D.G.;Kum, J.S.;Choi, K.H.;Jeong, H.M.;Park, J.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.504-516
    • /
    • 1997
  • Recently scientists and engineers are developing a system to get waste heat of low-temperature level with advanced heat pump, which have not been used up to now. As the reason, it is necessary to examine capability of using waste heat which is raised up in the tunnel of subway out of widely distributed low-temperature waste heat in large cities. Therefore we surveyed thermal environment of the tunnel of subway in $S\check{o}my\check{o}n$, downtown of Pusan, from November 1995 to December 1996 and developed a program to predict the thermal environment of subway on the basis of experimental data and the geometries of tunnels. This paper has proved availability of waste heat of subway when the measured results obtained in subway in the winter time and the simulated results of thermal environment prediction program are compared, as well as has reported results of estimating reliability of the simulation program. As the result, the charateristics of thermal environment in the tunnel of subway in $S\check{o}my\check{o}n$ station in the winter time are to be followed; 1) temperature in the tunnel is about $10^{\circ}C$ higher than outside air temperature, 2) temperature change in the tunnel is less than that in the platform so that we may obtain stable heat source, 3) and when the measured results obtained in subway in the winter time and the simulated results of thermal environment prodiction program is compared, both results show similar tendency. Therefore, we confirm estimating reliability of the simulation program.

  • PDF

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.