• Title/Summary/Keyword: internal flow

Search Result 2,526, Processing Time 0.032 seconds

An Experimental Study of the Factors Affecting the Performance of a Rotating Wickless Heat Pipe (회전식 히이트 파이프의 성능에 대한 실험적 연구)

  • Ko, Chang-Seog;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 1985
  • By using the hollow shaft with $0.5^{\circ}$ internal taper, ball valve and rubber packing, charging the working fluid at engineering vacuum degree (vacuum pressure higher than 1 torr) and carrying out experiments, it was investigated the performance of rotating heat pipe with variant operating conditions. In this experiment, it was shown that it is impossible the internal liquid flow was laminar film flow which agree with the assumption of present theoretical analyses, but the internal vorticity makes the heat transfer increase and for the maximum heat transfer there is optimal mass loading for the given heat pipe geometry and operational conditions.

  • PDF

Ideal Internal Carotid Artery Trapping Technique without Bypass in a Patient with Insufficient Collateral Flow

  • Chung, Joon-Ho;Shin, Yong-Sam;Lim, Yong-Cheol;Park, Min-Jung
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.260-263
    • /
    • 2009
  • Internal carotid artery (ICA) trapping can be used for treating intracranial giant aneurysm, blood blister-like aneurysms and ICA rupture during the surgery. We present a novel ICA trapping technique which can be used with insufficient collaterals flow via anterior communicating artery (AcoA) and posterior communicating artery (PcoA). A patient was admitted with severe headache and the cerebral angiography demonstrated a typical blood blister-like aneurysm at the contralateral side of PcoA. For trapping the aneurysm, the first clip was placed at the ICA just proximal to the aneurysm whereas the distal clip was placed obliquely proximal to the origin of the PcoA to preserve blood flow from the PcoA to the distal ICA. The patient was completely recovered with good collaterals filling to the right ICA territories via AcoA and PcoA. This technique may be an effective treatment option for trapping the aneurysm, especially when the PcoA preservation is mandatory.

Quantitative Analysis of Regional Cerebral Blood Flow Using $^{99m}Tc-HMPAO$ SPECT in Cerebrovascular Disease (뇌혈관질환에서 $^{99m}Tc-HMPAO$ SPECT를 이용한 국소뇌혈류의 정량적 분석)

  • Lee, Myung-Chul;Lee, Myung-Hae;Koh, Chang-Soon;Roh, Jae-Kyu;Myung, Ho-Jin;Lee, Sun-Ho;Han, Dae-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.1
    • /
    • pp.15-19
    • /
    • 1988
  • SPECT of regional cerebral blood flow was performed using $^{99m}Tc-HMPAO$ in 28 patients with cerebrovascular disease and quantitative analysis was done. Cerebral asymmetry index and percent index of asymmetry of cerebellar hemisphere of patients with cerebral infarction or ischemia were $0.764{\pm}0.576$ and $-5.6{\pm}7.1%$ and those of intracranial hemorrhage was $0.416{\pm}0.251$ and $-2.5{\pm}4.1%$ respectively. According to PIA of cerebellar hemisphere, 12 patients showed crossed cerebellar diaschisis. $^{99m}Tc-HMPAO$ SPECT seemed to be a useful tool for the evaluation of regional cerebral blood flow.

  • PDF

Effect of Kyungisan in on the Regional Cerebral Blood Flow and Mean Arterial Blood Pressure in Rats (균기산(勻氣散)이 흰쥐의 국소뇌혈류량 및 평균혈압에 미치는 효과)

  • Jung, Jong-An;Hong, Seok;Jun, Sang-Yun
    • Herbal Formula Science
    • /
    • v.15 no.2
    • /
    • pp.89-98
    • /
    • 2007
  • Kyungisan (KGS) has been used in oriental medicine for many centuries as a therapeutic agent for treatment of stroke caused by deficiency of qi(氣虛). This study was performed to evaluate effects of KGS extract on the regional cerebral blood flow(rCBF) and mean arterial blood pressure(MABP) in rats. The result of this study were as follow ; 1. KGS significantly increased rCBF irrelevant to MABP in normal rats, 2. To prescribe KGS after pretreatment with indomethacin(IDN) decreased rCBF as compared with control group to administered only KGS in normal rats. But the change of MABP is not significantly as compared with control group. 3. To prescribe KGS after pretreatment with methylen blue( MTB) decreased MABP and rCBF as compared with control group to administered only KGS in normal rats. Especially, it significantly decreased rCBF. These results suggest that KGS increase rCBF by enlargement diameter of pial artery in brain. The active mechanism of KGS is related with prostaglandin activated by cyclooxygenase. So, I suggest that KGS has an anti-ischemic effect through the improvement of cerebral blood flow and can be used for stroke.

  • PDF

Effects of alfaxalone on echocardiographic examination in healthy dogs

  • Kim, Ye-Won;Kim, Tae-Jun;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.4
    • /
    • pp.221-225
    • /
    • 2015
  • This study evaluated the effects of alfaxalone (3 mg/kg, intravenously) on echocardiographic examination in healthy dogs using echocardiography. Six adult Beagle dogs were used for this study. Left ventricular dimensions with systolic indexes, trans-blood flow at all cardiac valvular annulus and trans-mitral tissue Doppler values were measured from routine transthoracic echocardiography. Although the changes were not statistically significant, heart rate, left ventricular end-systolic diameter, left ventricular end-diastolic diameter, peak velocities of tricuspid A-wave and transpulmonic flow were increased after alfaxalone induction, while systolic blood pressure, fractional shortening, left ventricular ejection fraction, peak velocities of mitral E-wave, mitral A wave, tricuspid E-wave, transaortic flow and medial e'-, a'- and s'-peaks decreased after alfaxalone induction. No dogs showed hypoxemia during sedation, regardless of intubation and oxygen supply. Although alfaxalone showed mild cardiovascular depression, this protocol could be a good alternative sedative protocol for echocardiographic examination in healthy dogs because the cardiovascular depression was statistically and clinically insignificant. However, further studies in dogs with heart diseases should be conducted to confirm these findings after alfaxalone induction.

Development of a New Gerotor for Oil Pumps with Multiple Profiles(Ellipse1, Involute and Ellipse2) (타원 1-인벌루트-타원 2 형상을 조합한 새로운 형 제로터 개발)

  • Jung, Sung-Yuen;Kim, Moon-Saeng;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.5
    • /
    • pp.614-622
    • /
    • 2011
  • An internal lobe pump is suitable for oil hydraulics of machine tools, automotive engines, compressors, constructions and other various applications. In particular, the pump is an essential machine element of an automotive engine to feed lubricant oil. The subject of this paper is the theoretical analysis of internal lobe pump whose the main components are the rotors: usually the outer one is characterized by lobe with multiple profile(ellipse1, involute and ellipse2) shapes, while the inner rotor profile is determined as conjugate to the other. Also, the design of outer rotor depends on new applications with removing carryover phenomenon. The system generates new lobe profile and calculates automatically the flow rate and flow rate irregularity according to the lobe profile generated. In order to obtain rotor shapes in performance and to find optimize the design parameters, a Taguchi method is proposed in this paper. Results obtained from the analysis enable the designer and manufacturer of oil pump to be more efficient in this field.

Experimental Installation of Pressure Oscillation based on Pulse-driving Technique

  • YANG, Tian-hao;LIU, Pei-jin;JIN, Bing-ning
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.1
    • /
    • pp.58-61
    • /
    • 2015
  • Under the background of combustion instability in solid rocket motor, to study the relationship between pressure oscillations and dynamic process of propellant flames, it is necessary to simulate an oscillation environment with certain frequency, amplitude and duration. This paper presents an experimental installation of pressure oscillation based on pulse-driving technique, with which pressure oscillations features under different pulse-driving conditions were compared and analyzed. For the pulse-driver applied in this paper, a pressure oscillation with 0.15s-0.5s duration, 179Hz-210Hz first order frequency, 0.04MPa-0.35MPa amplitude is simulated. The test results show that an oscillation with higher frequency and lager amplitude can be obtained when pulse-driver is installed on the top of the installation cavity, while on the side, an oscillation with a longer duration and approximate cavity natural frequency can be simulated.

Nonlinear Combustion Instability Analysis of Solid Rocket Motor Based on Experimental Data

  • Wei, Shaojuan;Liu, Peijin;Jin, Bingning
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.58-61
    • /
    • 2015
  • Combustion instability in solid rocket motors is a long-term open problem since the first rockets were used. Based on the numerous previous studies, it is known that the limit cycle amplitude is one of the key characteristics of the nonlinear combustion instability in solid rocket motors. Flandro's extended energy balance corollary, aims to predict the limit cycle amplitude of complex, nonlinear pressure oscillations for rockets or air-breathing engines, and leads to a precise assessment of nonlinear combustion instability in solid rocket motors. However, based on the comparison with experimental data, it is revealed that the Flandro's method cannot accurately describe such a complex oscillatory pressure. Thus in this work we make modifications of the nonlinear term in the nonlinear wave equations which represents the interaction of different modes. Through this modified method, a numerical simulation of the cylindrical solid rocket has been carried out, and the simulated result consists well with the experimental data. It means that the added coefficient makes the nonlinear wave growth equations describe the experimental data better.

A Study on the Optimal Design According to the Piston Shape of the 3/8 Hydraulic Quick Coupler (3/8" 유압 퀵 커플러의 피스톤형상을 고려한 최적설계에 관한 연구)

  • Kim, Nam-Yong;Wu, Yu-Ting;Qin, Zhen;Cho, Yong-Min;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.66-71
    • /
    • 2021
  • A hydraulic quick coupler is a component used to easily connect or disconnect pipes or hoses that transfer high pressure fluid without leakage in various mechanical devices. In this study, to obtain an optimal design of a 3/8" hydraulic quick coupler, the effect of different shapes of the internal piston on the internal flow characteristics of the coupler was analyzed and evaluated through numerical analysis based on computational fluid dynamics. Subsequently, the optimal shape design of the internal piston was obtained by comparing the flow characteristics results such as velocity distribution, temperature distribution, and the pressure drop of the hydraulic quick coupler.

Effect of Nozzle Initial and Exit Wall Angles on Supersonic Flow Field in a Thrust Optimized Nozzle (추력이 최적화된 노즐의 초음속 유동에 대한 노즐벽 초기 및 출구각도의 영향)

  • Jeon, Tae Jun;Park, Tae Seon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.1-13
    • /
    • 2021
  • Effects of the nozzle wall angles on the supersonic flow field in a thrust optimized nozzle were numerically investigated. The combustor and operating condition of 30-tonf rocket engine was selected to study the optimum nozzle shape. The nozzle flow of combustion products was realized by the shifting equilibrium calculation for the propellant of kerosene-LOx. The change of nozzle wall angles induced different developing patterns of the internal and secondary shock wave. The optimum nozzle was obtained when the internal shock was in a specific position at the nozzle outlet. The nozzle wall angles of the optimum nozzle were very similar to those of the optimum nozzle which does not consider the shock wave.