• Title/Summary/Keyword: internal dose assessment

Search Result 107, Processing Time 0.025 seconds

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

Realistic Internal Dose Assessment of Indoor Radon Pollution by Groundwater (지하수로 인한 실내라돈오염시 현실적인 인체노출량 평가)

  • 유동한;이한수
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.117-118
    • /
    • 2002
  • 본 연구에서는 지하수로부터 방출된 실내라돈오염을 해석하기 위한 수학적 모델에서 모델인자들의 불확실성을 고려하고 인체축적량을 정량적으로 해석하는 PBPK모델을 사용하여 호흡을 통한 라돈의 인체축적량을 보다 현실적으로 평가하려고 한다. 우선, 전에 사용한 3 구역모델을 샤워실과 화장실을 구분하는 경계가 없다는 국내실정을 감안하여 보다 현실적으로 개량한 2-구역 모델을 개발하였다. (중략)

  • PDF

Direct Switch from Tiotropium to Indacaterol/Glycopyrronium in Chronic Obstructive Pulmonary Disease Patients in Korea

  • Lee, Sang Haak;Rhee, Chin Kook;Yoo, Kwangha;Park, Jeong Woong;Yong, Suk Joong;Kim, Jusang;Lee, Taehoon;Lim, Seong Yong;Lee, Ji-Hyun;Park, Hye Yun;Moon, Minyoung;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.2
    • /
    • pp.96-104
    • /
    • 2021
  • Background: Many chronic obstructive pulmonary disease (COPD) patients receiving monotherapy continue to experience symptoms, exacerbations and poor quality of life. This study aimed to assess the efficacy and safety of direct switch from once-daily tiotropium (TIO) 18 ㎍ to indacaterol/glycopyrronium (IND/GLY) 110/50 ㎍ once daily in COPD patients in Korea. Methods: This was a randomized, open-label, parallel group, 12-week trial in mild-to-moderate COPD patients who received TIO 18 ㎍ once daily for ≥12 weeks prior to study initiation. Patients aged ≥40 years, with predicted post-bronchodilator forced expiratory volume in 1 second (FEV1) ≥50%, post-bronchodilator FEV1/forced vital capacity <0.7 and smoking history of ≥10 pack-years were included. Eligible patients were randomized in a 1:1 ratio to either IND/GLY or TIO. The primary objective was to demonstrate superiority of IND/GLY over TIO in pre-dose trough FEV1 at week 12. Secondary endpoints included transition dyspnea index (TDI) focal score, COPD assessment test (CAT) total score, and rescue medication use following the 12-week treatment, and safety assessment. Results: Of the 442 patients screened, 379 were randomized and 347 completed the study. IND/GLY demonstrated superiority in pre-dose trough FEV1 versus TIO at week 12 (least squares mean treatment difference [Δ], 50 mL; p=0.013). Also, numerical improvements were observed with IND/GLY in the TDI focal score (Δ, 0.31), CAT total score (Δ, -0.81), and rescue medication use (Δ, -0.09 puffs/day). Both treatments were well tolerated by patients. Conclusion: A direct switch from TIO to IND/GLY provided improvements in lung function and other patient-reported outcomes with an acceptable safety profile in patients with mild-to-moderate airflow limitation.

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

Analysis of radioactivity levels and hazard assessment of black sand samples from Rashid area, Egypt

  • Abdel-Rahman, Mohamed A.E.;El-Mongy, Sayed A.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1752-1757
    • /
    • 2017
  • The aim of this study is to evaluate the radioactivity levels and radiological impacts of representative black sand samples collected from different locations in the Rashid area, Egypt. These samples were prepared and then analyzed using the high-resolution gamma ray spectroscopy technique with a high-purity germanium detector. The activity concentration ($A_c$), minimum detectable activity, absorbed gamma dose rate, external hazard index ($H_{ex}$), annual effective dose rate equivalent, radium equivalent, as well as external and internal hazard index ($H_{ex}$ and $H_{in}$, respectively) were estimated based on the measured radionuclide concentration of the $^{238}U$($^{226}Ra$) and $^{232}Th$ decay chains and $^{40}K$. The activity concentrations of the $^{238}U$, $^{232}Th$ decay series and $^{40}K$ of these samples varied from $45.11{\pm}3.1Bq/kg$ to $252.38{\pm}34.3Bq/kg$, from $64.65{\pm}6.1Bq/kg$ to $579.84{\pm}53.1Bq/kg$, and from $403.36{\pm}20.8Bq/kg$ to $527.47{\pm}23.1Bq/kg$, respectively. The activity concentration of $^{232}Th$ in Sample 1 has the highest value compared to the other samples; this value is also higher than the worldwide mean range as reported by UNSCEAR 2000. The total absorbed gamma dose rate and the annual effective dose for these samples were found to vary from 81.19 nGy/h to 497.81 nGy/h and from $99.86{\mu}Sv/y$ to $612.31{\mu}Sv/y$, which are higher than the world average values of 59 nGy/h and $70{\mu}Sv/y$, respectively. The $H_{ex}$ values were also calculated to be 3.02, 0.47, 0.63, 0.87, 0.87, 0.51 and 0.91. It was found that the calculated value of $H_{ex}$ for Sample 1 is significantly higher than the international acceptable limit of <1. The results are tabulated, depicted, and discussed within national and international frameworks, levels, and approaches.

Effect of belimumab in patients with systemic lupus erythematosus treated with low dose or no corticosteroids

  • Yeo-Jin Lee;Soo Min Ahn;Seokchan Hong;Ji-Seon Oh;Chang-Keun Lee;Bin Yoo;Yong-Gil Kim
    • The Korean journal of internal medicine
    • /
    • v.39 no.2
    • /
    • pp.338-346
    • /
    • 2024
  • Background/Aims: Systemic lupus erythematosus (SLE) responder index (SRI)-4 response has been achieved with belimumab treatment in patients with moderate disease activity in cornerstone clinical trials and following studies. However, most studies involved patients treated with a mean prednisolone-equivalent dose of approximately 10 mg/d and focused on the steroid-sparing effect of belimumab. We aimed to identify the effect of belimumab in patients with mild-to-moderate SLE who were treated with low-dose or no corticosteroids. Methods: We retrospectively reviewed the electronic medical records of patients treated with belimumab for at least 6 months between May 2021 and June 2022. The primary endpoint was SRI-4 response at 6 months. Results: Thirty-one patients were included (13 low dose- and 18 steroid non-users). The mean age was 39.2 ± 11.4 years, and 90.3% of patients were female. The baseline Safety of Estrogens in Lupus Erythematosus National Assessment-Systemic Lupus Erythematosus Disease Activity Index (SELENA-SLEDAI) score was 6.0 (4.0-9.0). The primary endpoint was achieved in 32.3% (10/31) of patients. Significant improvements in anemia, C4 levels, and SELENA-SLEDAI score were observed during treatment. Univariate analysis showed that the baseline SELENA-SLEDAI and arthritis were significantly associated with SRI-4 response at 6 months, and only the SELENA-SLEDAI remained significant (p = 0.014) in multivariate analysis. Conclusions: This cohort study is the first to report the efficacy of belimumab after minimizing the effect of corticosteroids. Belimumab showed efficacy in improving the SELENA-SLEDAI score, anemia, and low C4 in patients who did not receive corticosteroids or received only low doses.

A Study on the Food Consumption Rates for Off-site Radiological Dose Assessment around Korean Nuclear Power Plants (국내 원자력발전소 주변 주민의 방사선량 평가를 위한 음식물 섭취율 설정 연구)

  • Lee, Gab-Bock;Chung, Yang-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.183-196
    • /
    • 2008
  • The internal dose by food consumption mostly accounts for radiological dose of public around nuclear power plants (NPPs). But, food consumption rates applied to off-site dose calculation in Korea which are the result of field investigation around Kori NPP by the KAERI (Korea Atomic Energy Research Institute) in 1988, are not able to reflect the latest dietary characteristics of Korean. The food consumption rates to be used for radiological dose assessment in Korea are based on the maximum individual of US NRC (Nuclear Regulatory Commssion) Regulatory Guide 1.109. However, the representative individual of the critical group is considered in the recent ICRP (International Commission on Radiological Protection) recommendation and European nations' practice. Therefore, the study on the re-establishment of the food consumption rates for individual around nuclear power plant sites in Korea was carried out to reflect on the recent change of the Korean dietary characteristics and to apply the representative individual of critical group to domestic regulations. The Ministry of Health and Welfare Affairs has investigated the food and nutrition of nations every 3 years based on the Law of National Health Improvement. The statistical data such as mean, standard deviation, various percentile values about food consumption rates to be used for the representative individual of the critical group were analyzed by using the raw data of the national food consumption survey in $2001{\sim}2002$. Also, the food consumption rates for maximum individual are re-estimated.

Association between Inhaled Corticosteroid Use and SARS-CoV-2 Infection: A Nationwide Population-Based Study in South Korea

  • Lee, Sang Chul;Son, Kang Ju;Han, Chang Hoon;Jung, Ji Ye;Park, Seon Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.1
    • /
    • pp.80-88
    • /
    • 2022
  • Background: Although it is known that inhaled corticosteroid (ICS) use may increase the risk of respiratory infection, its influence on the risk of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection remains unknown. Thus, the aim of this study was to investigate the association between ICS use and the positivity of SARS-CoV-2 infection among patients with chronic respiratory diseases. Methods: Nationwide data of 44,968 individuals with chronic respiratory diseases tested for SARS-CoV-2 until May 15, 2021 were obtained from the Ministry of Health and Welfare and Health Insurance Review and Assessment Service in Korea. The positivity of SARS-CoV-2 infection was retrospectively analysed according to the prescription, type, and dose of ICS taken one year before SARS-CoV-2 test. Results: Among 44,968 individuals tested, 931 (2.1%) were positive for SARS-CoV-2. A total of 7,019 patients (15.6%) were prescribed ICS one year prior to being tested for SARS-CoV-2. Low, medium, and high doses of ICS were prescribed in 7.5%, 1.6%, and 6.5% of total cases, respectively. Among types of ICS, budesonide, fluticasone, beclomethasone, and ciclesonide were prescribed in 3.7%, 8.9%, 2.3%, and 0.6% of total cases, respectively. A multivariate analysis showed no significant increase in infection with ICS use (odds ratio, 0.84; 95% confidence interval, 0.66-1.03). Moreover, there were no associations between the positivity of infection and the dose or type of ICS prescribed. Conclusion: Prior ICS use did not increase the positivity for SARS-CoV-2 infection. Moreover, different doses or types of ICS did not affect this positivity.

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.

Towards Quantitative Assessment of Human Exposures to Indoor Radon Pollution from Groundwater

  • Donghan Yu;Lee, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.43-51
    • /
    • 2001
  • A report by the national research council in the United States suggested that many lung cancer deaths each year be associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundations. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the quantitative assessment of human exposures to radon released from the groundwater into indoor air. At first, a three-compartment model is developed to describe the transfer and distribution of radon released from groundwater in a house through showering, washing clothes, and flushing toilets. Then, to estimate a daily human exposure through inhalation of such radon for an adult. a physiologically-based pharmacokinetic(PBPK) model is developed. The use of a PBPK model for the inhaled radon could provide useful information regarding the distribution of radon among the organs of the human body. Indoor exposure patterns as input to the PBPK model are a more realistic situation associated with indoor radon pollution generated from a three-compartment model describing volatilization of radon from domestic water into household air. Combining the two models for inhaled radon in indoor air can be used to estimate a quantitative human exposure through the inhalation of indoor radon for adults based on two sets of exposure scenarios. The results obtained from the present study would help increase the quantitative understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF