• Title/Summary/Keyword: internal dose

Search Result 1,300, Processing Time 0.03 seconds

Assessment of Fluoride Exposure by Oral Health Behaviors using the ConsExpo Model (ConsExpo 모델을 이용한 구강건강행위에 따른 불소노출평가)

  • Oh, Na-Rae;Jeong, Mi-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.498-504
    • /
    • 2017
  • Oral health behavior such as toothbrushing one's teeth, using dentifrice and such are an important part of improving one's oral health and therefore quality of life. However, it is also necessary to research exposure to harmful chemical substances. Therefore, this study investigated the factors that affect researching fluorine exposure resulting from oral health behavior initiation so that correct oral health guidelines can be provided. As a result of applying the fluorine compound's oral exposure in the ConsExpo 5.0 model, adult males' oral external dose was at 0.000196 mg/kg, oral acute (internal) dose at 0.000196 mg/kg/day and oral chronic (internal) dose at 0.000465 mg/kg/day. In the case of females, the oral dose was at $4.1{\times}10^{-6}mg/kg$, oral acute (internal) dose at $4.1{\times}10^{-6}mg/kg$ and oral chronic (internal) dose at $9.99{\times}10^{-6}mg/kg/day$.

ABSORBED INTERNAL DOSE CONVERSION COEFFICIENTS FOR DOMESTIC REFERENCE ANIMALS AND PLANT

  • Keum, Dong-Kwon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ($^3H,\;^7Be,\;^{14}C,\;^{40}K,\;^{51}Cr,\;^{54}Mn,\;^{59}Fe,\;^{58}Co,\;^{60}Co,\;^{65}Zn,\;^{90}Sr,\;^{95}Nb,\;^{99}Tc,\;^{106}Ru,\;^{129}I,\;^{131}I,\;^{136}Cs,\;^{137}Cs,\;^{140}Ba,\;^{140}La,\;^{144}Ce,\;^{238}U,\;^{239}Pu,\;^{240}Pu$) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (${\mu}Gyd^{-1}$ per $Bqkg^{-1}$) ranged from $10^{-6}$ to $10^{-2}$ according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as $^{238}U,\;^{239}Pu$, and $^{240}Pu$, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of $^{239}U,\;^{240}Pu,\;^{238}U,\;^{14}C,\;^3H$, and $^{99}Tc$ were independent of the organism.

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.

Evaluation Internal Radiation Dose of Pediatric Patients during Medicine Tests Using Monte Carlo Simulation (몬테칼로 시뮬레이션을 이용한 소아 핵의학검사 시 인체내부 장기선량 평가)

  • Lee, Dong-yeon;Kang, Yeong-rok
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.109-115
    • /
    • 2021
  • In this study, a physical evaluation of internal radiation exposure in children was conducted using nuclear medicine test(Renal DTPA Dynamic Study) to simulate the distribution and effects of the radiation throughout the tracer kinetics over time. Monte Carlo simulations were performed to determine the internal medical radiation exposure during the tests and to provide basic data for medical radiation exposure management. Specifically, dose variability based on changes in the tracer kinetic was simulated over time. The internal exposure to the target organ (kidney) and other surrounding organs was then quantitatively evaluated and presented. When kidney function was normal, the dose to the target organ(kidney) was approximately 0.433 mGy/mCi, and the dose to the surrounding organs was approximately 0.138-0.266 mGy/mCi. When kidney function was abnormal, the dose to the surrounding organs was 0.228-0.419 mGy/mCi. This study achieved detailed radiation dose measurements in highly sensitive pediatric patients and enabled the prediction of radiation doses according to kidney function values. The proposed method can provide useful insights for medical radiation exposure management, which is particularly important and necessary for pediatric patients.

Surface Treatment of Eggshells with Low-Energy Electron Beam

  • Kataoka, Noriaki;Kawahara, Daigo;Sekiguchi, Masayuki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.8-13
    • /
    • 2021
  • Background: Salmonella enteritidis (SE) was the main cause of the pandemic of foodborne salmonellosis. The surface of eggs' shells can be contaminated with this bacterium; however, washing them with sodium hypochlorite solution not only reduces their flavor but also heavily impacts the environment. An alternative to this is surface sterilization using low-energy electron beam. It is known that irradiation with 1 kGy resulted in a significant 3.9 log reduction (reduction factor of 10,000) in detectable SE on the shell. FAO/IAEA/WHO indicates irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard. On the other hand, the Food and Drug Administration has deemed a dose of up to 3 kGy is allowable for eggs. However, the maximum dose permitted to be absorbed by an edible part (i.e., internal dose) is 0.1 Gy in Japan and 0.5 Gy in European Union. Materials and Methods: The electron beam (EB) depth dose distribution in the eggshell was calculated by the Monte Carlo method. The internal dose was also estimated by Monte Carlo simulation and experimentation. Results and Discussion: The EB depth dose distribution for the eggshells indicated that acceleration voltages between 80 and 200 kV were optimal for eggshell sterilization. It was also found that acceleration voltages between 80 and 150 kV were suitable for reducing the internal dose to ≤ 0.10 Gy. Conclusion: The optimum irradiative conditions for sterilizing only eggshells with an EB were between 80 and 150 kV.

Fibrinolysis with Lower Dose Urokinase in Patients with Complicated Parapneumonic Effusion

  • Lee, Seul;Lee, Heock;Lee, Dong Hyun;Kang, Bo Hyoung;Roh, Mee Sook;Son, Choohee;Kim, Sung Hyun;Lee, Hyun-Kyung;Um, Soo-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.2
    • /
    • pp.134-139
    • /
    • 2021
  • Background: Intrapleural urokinase is one of the most widely used fibrinolytic agents in the treatment of complicated parapneumonic effusion (CPPE). However, little research has been performed on the optimal urokinase dosage. The aim of this study was to evaluate the treatment efficacy of half dose urokinase compared with conventional dose urokinase. Methods: We retrospectively enrolled 92 patients with CPPE or empyema who underwent intrapleural urokinase treatment at two tertiary hospitals. Patients received antibiotics, chest tube drainage, and other treatments as part of routine care. The primary outcome was the treatment success rate in the half dose urokinase group (50,000 IU daily for maximal 6 days) and the conventional dose urokinase group (100,000 IU daily). Treatment success was defined as clinical and radiological improvements without surgical treatment or re-admission within one month. Results: Forty-four patients received half dose urokinase, whereas 48 patients were treated with conventional dose urokinase. Both groups were relatively well matched at baseline, excluding higher serum white blood cell count and higher empyema prevalence in the half dose urokinase group. The treatment success rate was not different between the two groups (p=0.048). There were no differences in the rate of in-hospital death and surgical treatment, hospitalization duration, and indwelling catheter duration. In the multivariate analysis, urokinase dose was not a predictor of treatment success. Conclusion: Half dose intrapleural urokinase is equally effective conventional dose urokinase in treating patients with CPPE or empyema.

Single Dose Toxicity Test of Bojungikkeehapdaechilkitang water extract in Male and Female ICR Mice (보중익기합대칠기탕(補中益氣合大七氣湯) 추출물의 ICR마우스에서 경구 단회투여독성 평가)

  • Bae, Young-Chul;Choi, Bin-Hye;Kim, Dong-Woo;Hur, Jin-Il;Kim, Dae-Jun;Byun, Joon-Seok
    • The Journal of Internal Korean Medicine
    • /
    • v.26 no.2
    • /
    • pp.369-378
    • /
    • 2005
  • An herbal water extract of Bojungikkeehapdaechilkitang(BDT) was prepared to test it for single-dose and repeated-dose toxicity, genotoxicity and reproductive toxicity, and to obtain a 50% lethal dose$(LD_{50})$, approximated lethal dose(ALD), and approximated target organs for BDT. The extract was tested on female and male ICR mice according to KFDA Guideline 1999-61 at doasge level of 2000, 1000, 500, 250 and 125mg/kg/10mL In this study, clinical signs, mortalities and gross findings of principal organs were observed for 14 days of single dosing, and afterwards in some cases. The ALD and $LD_{50}$ of BDT extract obtained in this study was>2000mg/kg for both male and female ICR mice. Also, any possible digestive toxicity of BDT extract was found to be above 1000mg/kg in both male and female ICR mice. The results of this study strongly suggest that BDT extract has no toxic effect at dosage level below 500mg/kg.

  • PDF

Effect of a Dose-Escalation Regimen for Improving Adherence to Roflumilast in Patients with Chronic Obstructive Pulmonary Disease

  • Hwang, Hyunjung;Shin, Ji Young;Park, Kyu Ree;Shin, Jae Ouk;Song, Kyoung-hwan;Park, Joonhyung;Park, Jeong Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.4
    • /
    • pp.321-325
    • /
    • 2015
  • Background: The adverse effects of the phosphodiesterase-4 inhibitor roflumilast, appear to be more frequent in clinical practice than what was observed in chronic obstructive pulmonary disease (COPD) clinical trials. Thus, we designed this study to determine whether adverse effects could be reduced by starting roflumilast at half the dose, and then increasing a few weeks later to $500{\mu}g$ daily. Methods: We retrospectively investigated 85 patients with COPD who had taken either $500{\mu}g$ roflumilast, or a starting dose of $250{\mu}g$ and then increased to $500{\mu}g$. We analyzed all adverse events and assessed differences between patients who continued taking the drug after dose escalation and those who had stopped. Results: Adverse events were reported by 22 of the 85 patients (25.9%). The most common adverse event was diarrhea (10.6%). Of the 52 patients who had increased from a starting dose of $250{\mu}g$ roflumilast to $500{\mu}g$, 43 (82.7%) successfully maintained the $500{\mu}g$ roflumilast dose. No difference in factors likely to affect the risk of adverse effects, was detected between the dose-escalated and the discontinued groups. Of the 26 patients who started with the $500{\mu}g$ roflumilast regimen, seven (26.9%) discontinued because of adverse effects. There was no statistically significant difference in discontinuation rate between the dose-escalated and the control groups (p=0.22). Conclusion: Escalating the roflumilast dose may reduce treatment-related adverse effects and improve tolerance to the full dose. This study suggests that the dose-escalated regimen reduced the rate of discontinuation. However, longer-term and larger-scale studies are needed to support the full benefit of a dose escalation strategy.

Feasibility of normal tissue dose reduction in radiotherapy using low strength magnetic field

  • Jung, Nuri Hyun;Shin, Youngseob;Jung, In-Hye;Kwak, Jungwon
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.226-232
    • /
    • 2015
  • Purpose: Toxicity of mucosa is one of the major concerns of radiotherapy (RT), when a target tumor is located near a mucosal lined organ. Energy of photon RT is transferred primarily by secondary electrons. If these secondary electrons could be removed in an internal cavity of mucosal lined organ, the mucosa will be spared without compromising the target tumor dose. The purpose of this study was to present a RT dose reduction in near target inner-surface (NTIS) of internal cavity, using Lorentz force of magnetic field. Materials and Methods: Tissue equivalent phantoms, composed with a cylinder shaped internal cavity, and adjacent a target tumor part, were developed. The phantoms were irradiated using 6 MV photon beam, with or without 0.3 T of perpendicular magnetic field. Two experimental models were developed: single beam model (SBM) to analyze central axis dose distributions and multiple beam model (MBM) to simulate a clinical case of prostate cancer with rectum. RT dose of NTIS of internal cavity and target tumor area (TTA) were measured. Results: With magnetic field applied, bending effect of dose distribution was visualized. The depth dose distribution of SBM showed 28.1% dose reduction of NTIS and little difference in dose of TTA with magnetic field. In MBM, cross-sectional dose of NTIS was reduced by 33.1% with magnetic field, while TTA dose were the same, irrespective of magnetic field. Conclusion: RT dose of mucosal lined organ, located near treatment target, could be modulated by perpendicular magnetic field.

The Internal Dose Assessment of Ingested Radon using a PBPK Model for Repeated Oral Exposures (음용수를 통한 라돈의 반복섭취시 동적 약리학모델을 활용한 체내거동 평가)

  • 유동한;이창우
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2001
  • A daily newspaper in Korea addressed an controversial issue recently that the concentration of radon measured from the groundwater in Taejon was found out a relatively high level. The cancer risk arising from ingestion of such radon should be derived from calculation of the dose absorbed by the tissues at risk. The study performed by the National Research Council in United States confirmed that the use of a PBPK model for the ingested radon could provide the useful information regarding the distribution of radon among the organs of the body. This study presents an approach for the internal dose assessment of ingested radon for this case. At first, the study develops a PBPK model for ingested radon. However, the important issue is how to simulate a more realistic situation using the model associated with repeated oral doses rather than a single oral dose. The simulations are performed for repeated oral exposures per 8-hour interval using the PBPK model for a male adult. The concentration and cumulative value of radon concentration are calculated and analyzed for lung tissue and adipose group, respectively. The results could be used for the realistic prediction of the internal dose of radon in the human body for repeated oral exposures.

  • PDF