• 제목/요약/키워드: internal defect

검색결과 441건 처리시간 0.026초

실패한 족관절 인공관절 치환술 후 큰 골결손에서 내고정 없이 시행한 족관절 구제술: 증례 보고 (Ankle Salvage Procedure without Internal Fixation for Large Bone Defect after Failed Total Ankle Arthroplasty: A Case Report)

  • 박만준;은일수;정철용;고영철;류총일;김민우;황금민
    • 대한족부족관절학회지
    • /
    • 제18권2호
    • /
    • pp.76-79
    • /
    • 2014
  • In treatment of failure in ankle joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation, treatment of large bone defects is considerably important for ankle joint stability and union, therefore, the choice of treatment for large bone defects is use of femoral head or iliac crest bone graft and rigid internal fixation. Because first generation total ankle arthroplasty performed for the first time using a cemented fixation technique requires a large amount of bone resection during re-surgery and there is some possibility of a larger bone defect after removal of implants, in cases where prosthesis for the defect is needed, performance of palliative femoral head or iliac crest bone graft and rigid internal fixation can be difficult. We report on a case of a 48-year-old woman who had experienced ankle pain for 25 years since undergoing total ankle arthroplasty. Because the patient had little ankle motion and rigid soft tissue despite a large bone defect caused by aseptic loosening, a good outcome was obtained only for the femoral cancellous bone graft using allo femoral head without internal fixation.

원심모형시험을 이용한 필댐 취약부 모니터링 (Monitoring of Fill Dams for Internal Defect via Centrifuge Model Tests)

  • 추연욱;조성은;신동훈
    • 대한토목학회논문집
    • /
    • 제32권2C호
    • /
    • pp.37-47
    • /
    • 2012
  • 본 연구에서는 필댐을 위한 모니터링 기술에 적용할 수 있는 물리량으로 간극수압, 온도와 전기저항을 선정하였고, 이를 원심모형시험 상에서 계측할 수 있는 시스템을 구축하였다. 또한, 코아형 필댐 모형 단면을 설계하고, 코아죤에 취약부가 없는 정상적인 경우, 코아죤 하부에 부분적인 취약부가 발생한 경우, 코아죤 하부에 취약부가 커져서 상하류 사력죤이 연결되는 경우를 포함하여, 총 세 가지 모형을 제작하고, 원심모형시험을 수행하였다. 원심력장이 작용하는 조건에서, 담수시에 나타나는 침투 흐름의 변화에 따라 간극수압, 온도 및 전기저항의 변화를 모니터링하였다. 원심모형시험을 통하여, 간극수압, 온도 및 전기저항의 변화가 취약부 존재에 따라 다르게 나타나는 것을 확인할 수 있었고, 간극수압, 온도와 전기 저항이 필댐의 내부 취약부를 탐지하기 위한 모니터링 기술 개발에 적용될 수 있음을 확인하였다.

전단간섭계를 이용한 압력용기 내부 결함 측정시 전단량 변화에 따른 오차분석 (Analysis of Error Rate in the Variations of Shearing Amount in Measuring the Internal Defect using a Shearography)

  • 홍경민;강영준;최인영;안용진;윤석범
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.726-732
    • /
    • 2012
  • Pipe and Pressure Vessels that is used in power plant and chemical industry have many Internal Defects that is corrosion caused by the flow of fluid. These Internal Defects that have possibility of explosion are very dangerous because it can not see from the outside. This days many companys using NDT method to find an Internal Defect. Most of the NDT methods have limitations that are constraint of shape and materials. But Sheargoraphy have many advantages compared conventional NDT method. It has very fast measuring speed, non-destructive and non contacting measurement. As well as it hasn't constraint of shape and materials. As a paper on the analysis of measurement of error, the important factors were the Shearing Amount and pressure, and discovered measurement of the Internal Defect of the object by using shearography. The optimal Shearing Amount and pressure was discovered and utilized.

집중유도 교류 전위차법을 이용한 철도차량 차륜의 표면과 내부 결함 평가 (Evaluation of Surface and Sub-surface defects in Railway Wheel Using Induced Current Focused Potential Drops)

  • 이동형;권석진
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2007
  • Railway wheels in service are regularly checked by ultrasonic testing, acoustic emission and eddy current testing method and so on. However, ultrasonic testing is sometimes inadequate for sensitively detecting the cracks in railway wheel which is mainly because of the fact of crack closure. Recently, many researchers have actively fried to improve precision for defect detection of railway wheel. The development of a nondestructive measurement tool for wheel defects and its use for the maintenance of railway wheels would be useful to prevent wheel failure. The induced current focusing potential drop(ICFPD) technique is a new non-destructive tasting technique that can detect defects in railway wheels by applying on electro-magnetic field and potential drops variation. In the present paper, the ICFPD technique is applied to the detection of surface and internal defects for railway wheels. To defect the defects for railway wheels, the sensor for ICFPD is optimized and the tests are carried out with respect to 4 surface defects and 6 internal defects each other. The results show that the surface crack depth of 0.5 mm and internal crack depth of 0.7 mm in wheel tread could be detected by using this method. The ICFPB method is useful to detect the defect that initiated in the tread of railway wheels

열화상 비파괴 검사법을 이용한 도로포장 결함 검출 (Detecting of the defects of pavement of a road by using infrared thermography)

  • 심준기;김기현
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.69-76
    • /
    • 2015
  • The purpose of this paper is to find an limitation to detect the defect of damaged asphalt pavement structures for infrared thermography. We use heat source of a natural light to detect the defect efficiently. The heat source was applied to the asphalt specimens. Four asphalt specimens were used: one was the asphalt containing depth of 1cm internal timber, two was the asphalt containing depth of 2cm internal void, Three was the asphalt containing depth of 3cm internal timber and four was not the asphalt containing internal timber. It was found that the depth of 3cm internal timber could be detected by this method. In addition, we used the image processing to make the damage zone displayed clear in the image obtained from the thermographic operation.

Miniature Schunauzer Dog에서 발생한 심방중격 결손 증례 (A Case of Atrial Septal Defect (ASD) in a Miniature Schunauzer Dog)

  • 박철;최치봉;김일환;박희명
    • 대한수의학회지
    • /
    • 제43권2호
    • /
    • pp.307-310
    • /
    • 2003
  • An atrial septal defect (ASD) is congenital heart disease with a communication between the atria, which allows blood to shoot from the atrium with pressure. A 3-month-old female Miniature Schunauzer was referred to the Veterinary Teaching Hospital of Konkuk University for the evaluation of systolic heart murmur. At presentation, the mucous membrane was cyanotic. On physical examination, an ejection-type systolic murmur was auscultated at the pulmonic area. In addition, thoracic radiography showed enlargement of main pulmonary artery and right atrial/ventricular enlargement. Echocardiography revealed dilated right atrium and atrial septal defect. However, mitral and tricuspid valve were still intact and well tolerating. The presence of an ASD was confirmed by identifying flow across the defect with color Doppler imaging. Doppler echocardiography provides a means of non-invasive documentation and quantification of ASD. Complete blood count and serum chemistry were not remarkable. Although large defect was confirmed between the two atrium, the patient did not show any obvious clinical signs of heart failure at this time.

ESPI 를 이용한 곡관 감육 결함부의 변형률 분포 측정 (Strain Distribution Measurement for Wall Thinning Defect in Pipe Bends by ESPI)

  • 아흐터나심;김경석;정성욱;박종현;최정석;정현철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.120-125
    • /
    • 2007
  • Put Abstract text here The strain distribution measurement for wall thinned pipe bends by ESPI is presented. Defect types observed in the steel piping in the nuclear power plants (NPP) are the crack at the weld part and the wall thinning defect in the pipe bends. Especially, the wall thinning defects in the pipe bends due to the flow-accelerated corrosion (FAC) is a main type of defects observed in the carbon steel piping system. ESPI is one of the optical non-destructive testing methods and can measure the stress and the strain distribution of the object subjected by the tensile loading or the internal pressure. In this paper, the strain distribution of the wall thinned pipe bends due to the internal pressure will be measured by ESPI technique and the results are discussed. From the results, the size of the wall thinning defect can also be measured approximately.

  • PDF

엘보우 붕괴모멘트에 미치는 국부 감육결함의 원주방향 위치에 대한 영향 (Effect of Circumferential Location of Local Well Thinning Defect on the Collapse Moment of Elbow)

  • 김진원;이장곤
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.55-61
    • /
    • 2005
  • The purpose of this study is to investigate the effect of circumferential location of local wall thinning defect on the collapse behavior of an elbow. Thus, the present study conducts three-dimensional finite element analysis on the 90-degree elbow containing a local wall thinning at intrados, crown and extrados of bend region and evaluates the collapse moment of wall thinned elbow under various thinning shapes and loading conditions. Combined internal pressure and bending moment are considered as an applied load. The internal pressure of $0\~20MPa$ and both closing and opening mode bending are employed. The results of analysis show that the reduction in collapse moment of the elbow by local wall thinning is more significant for a defect locating at crown than for a defect locating at intrados or at extrados. Also, the effect of internal pressure on the collapse moment of wall thinned elbow depends on the circumferential location of thinning defect and applied bending mode.

Pulmonic stenosis with atrial septal defect in a Siamese cat

  • Kim, Ji-Youn;Lee, Sung-Wook;Lee, Seung-Gon;Suh, Sang-Il;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제57권1호
    • /
    • pp.63-66
    • /
    • 2017
  • A 6-month-old mature intact female Siamese cat presented with exertional dyspnea. Diagnostic studies revealed pleural effusion, grade 4/6 left basal systolic murmur, deep S-wave in electrocardiograph leads I, II, and III, cardiomegaly with pleural effusion on radiography, pulmonic systolic (~5.8 m/sec) and tricuspid (3.6 m/sec) regurgitant jets, atrial septal defect, and a hypoplastic right outflow tract. Based on these results, the case was diagnosed as pulmonic stenosis with atrial septal defect. To the best of our knowledge, this is the first case report describing pulmonic stenosis with atrial septal defect in a cat in Korea.