• Title/Summary/Keyword: internal circulation

Search Result 484, Processing Time 0.026 seconds

Development and Characterization of a 400-W Slab-type Nd:YAG Gain Module

  • Cha, Yong-Ho;Lee, Sungman;Lim, Gwon;Baik, Sung-Hoon;Kwon, Sung-Ok;Cha, Byung-Heon;Lee, Jung-Hwan;Kang, Eung-Cheol
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.53-56
    • /
    • 2012
  • We have developed a slab-type Nd:YAG gain module based on the techniques of conduction cooling and end pumping. The Nd:YAG slab is end-capped on both ends by undoped pure YAG and is pumped through the end-caps by stacked arrays of laser diode bars. The slab's surfaces of total internal reflection are in contact on both sides with microchannel cooling blocks which are cooled by water circulation. The power oscillator based on the gain module generates more than 400 W at 1-kW pumping with a slope efficiency of 55%. The small-signal gain of the gain module is 10 in a single zig-zag pass, and the amplified beam shows a near diffraction-limited beam quality.

The Improvement of Bio-gas Production through the Change of Sludge-Recycle Ratio with Two-Stage Anaerobic Digestion (2단 혐기성소화조의 슬러지 반송율 변화를 통한 Bio-Gas 생산 증대)

  • Kwon, Kooho;Lee, Taewoo;Jung, Yongjun;Min, Kyungsok
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1061-1066
    • /
    • 2014
  • This study has cross checked the change of internal sludge-recycle in Anaerobic-Digestion, and researched about not only the improvement of Bio-gas production from the digested sludge but also the efficient method of sludge minimization. Ultimate object of the study is to reduce the amount of sludge by the improved efficiency of contact with the organic-matter and the microbes in Anaerobic-Digestion. The sludge-recycle fluidized sludge layer and raised the activity of the sludge, the optimal sludge-recycle ratio, VS and COD removal ratio were 1,000%, 28.2% and 27.7%, respectively. Through these results of this study, it may be of use to treat waste sludge by the sludge-recycle ratio in terms of minimization and circulation of resources.

An Analysis on the Safety related to Architectural Elements in Housing (주거 공간 내 건축 구성 요소의 안전성 분석)

  • Yi, Hoon;Lee, Yong-Hee;Jeong, Sang-Kyu
    • KIEAE Journal
    • /
    • v.5 no.4
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this study is to analyze the safety issues with regard to architectural elements in housing. Causes of accidents and threats to health are reviewed for 'safety' aspects. Threats to health tend to draw more attention due to recent increase of SHS and its public perceptions. The majority of victims by accidents in residential houses are on juveniles aged under 14 in bathrooms and living rooms. Non-slip finish materials are recommended to floors for access and circulation and protective pads to furniture edges. Colored glass may increase the safety of the windows in the living room. Handles and non-slip mats will be a good addition for the safety. Human scale design of the kitchen system is mandatory and appropriate size of storages for hazardous equipment are to be provided. Passive air ventilation for better air quality by dwellers in residence is occasionally used whereas large-scale apartments provide mechanical ventilation to supplement the volume of fresh air. Since the internal air quality is proved one of the major causes of atopic and respiratory diseases, steady effort to achive better air quality utilizing appropriate materials, plants and equipment is mandatory. Frequent cleaning and the use of anti-fungus materials are necessary because House Dust Mites are believed to be one of main causes of such diseases.

Predictions of Heat and Mass Transfer Rates to a Spray Droplet Experiencing Condensation (응축을 수반하는 분무수적으로의 열 및 질량전달률 예측)

  • 이상균;조종철;신원기;조진호;서정일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1763-1773
    • /
    • 1991
  • 본 연구에서는 포화수증기와 공기의 혼합기내에서 분무수적으로의 열 및 질량 전달률을 계산하기 위하여 수적의 부분혼합모형과 비혼합모형에 대하여 수적내 과도온 도분포의 해석해를 적용성이 보장되면서도 계산상의 어려움이 수반되지 않는 형태로 구하기 위하여 수적내부의 열전도해석에 있어서 적분법을 적용하였다. 적분법으로 얻어지는 과도온도분포의 해는 유한차의 다항식으로 표시되어 비혼합모형인 경우 각시 간 구간의 경계에서의 온도분포가 연속성을 유지하면서 물성치들의 온도에 대한 종속 성이 쉽게 고려되고 계산도 용이한 형태이다. 본 보에서 제시하는 해석결과의 적용 성을 조사하기 위하여 완전혼합모형을 포함하는 세가지 수적모형들에 대한 계산결과들 로부터 얻어진 시간변화에 따른 수적의 무차원 체적평균온도변동을 유효한 실험결과들 과 비교, 검토하였으며, 부분혼합모형에 대하여 혼합기의 압력, 수적의 초기온도, 혼 합기 속에 포함되어 있는 수증기의 체적분율, 수적의 초기크기, 수적의 초기속도 및 분사각도가 주위혼합기로부터 수적으로 전달되는 열 및 질량전달에 미치는 영향을 조] 사하고 도출된 대표적인 검토 결과를 제시하였다.

Internal Flow Analysis for a 10 inch Ball Valve using Flow Similarity (유동상사를 이용한 10인치 볼밸브 내부유동 분석)

  • LEE, SANG-MOON;JANG, CHOON-MAN
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.4
    • /
    • pp.386-392
    • /
    • 2015
  • Flow characteristics inside a 10 inch ball valve have been analyzed using three-dimensional numerical analysis and experiments. Continuity and three-dimensional Reynolds-averaged Navier-Stokes equations have been used as governing equations for the numerical analysis. The numerical model has been constructed through the grid dependency test and validation with the results of experiments to ensure reliability and numerical effectiveness. The shear stress transport (SST) model has been used as the turbulence closure. The experimental test-rig has been constructed to measure pressure, temperature and flow rate along the pipeline. Some valve opening angles have been tested to evaluate the flow characteristics inside the ball valve and pipeline. The results show that the rapid pressure variations is observed while the valve opening angle decreases, which caused by flow separation at the downstream of the ball valve.

Numerical Analysis on the Effect of Flow Rate Variation in Double-Suction Centrifugal Pump (양흡입 원심펌프에 있어서 유량변화의 영향에 관한 수치해석적 연구)

  • An, Young-Joon;Shin, Byeong-Rog
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.51-56
    • /
    • 2010
  • A numerical simulation is carried out to investigate the effect of flow rate variation and performance characteristics of double-suction centrifugal pump. Two types of pump which have different impeller inlet breadth and curvature of the shroud line consist of six blades impeller and shroud ring. Finite-volume method with structured mesh and $k-\omega$ Shear Stress Transport turbulence model was used to guaranty more accurate prediction of turbulent flow in the pump impeller. Total head, power and overall efficiency were calculated to obtain performance characteristics of two types of pump according to the variation of flow rate. From the results, impeller having smooth curve along the shroud line obtained good performance. The lower flow rate, the more circulation region, flow unsteadiness and complicate flow pattern are observed. Complicated internal flow phenomena through impellers such as flow separation, pressure loss, flow unsteadiness and performance are investigated and discussed.

Change of Sludge-Recycle Ratio for the Bio-gas Production Improvement and Minimization with Two-Stage Anaerobic Digestion (2단 혐기성소화공정에서 반송변화를 통한 Bio-gas 생산량 증대 및 감량화)

  • Lee, Tae-Woo;Yang, Hae-Young;Do, Choong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.3
    • /
    • pp.83-86
    • /
    • 2012
  • This study have cross checked the change of internal sludge-recycle in Full-scale Anaerobic-Digestion, and researched about not only the improvement of Bio-gas production from the digested sludge but also the efficient method of sludge minimization. Ultimate aim of the study is to reduce the amount of sludge by the improved efficiency of contact with the organic-matter and the microbes in Anaerobic-Digestion. The sludge-recycle fluidized sludge layer and raised the activity of the sludge, The sludge-recycle ratio of optimum was 500%, VS and COD removal ratio respectively appeared with 67.8% and 70.4%. Through these result of this study, it may be positive view to treat waste sludge by the sludge-recycle ratio in terms of minimization and circulation of resources.

Application Study of small-scale sewage treatment system with A2/O precess in Mongolia (A2/O 공법을 이용한 소규모 하수처리시스템의 몽골 현지 적용에 관한 연구)

  • Yeo, Yeongki;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.431-440
    • /
    • 2017
  • The small-scale sewage treatement system with $A^2/O$ process was applied to evaluate applicability for Mongolian sewage, It was designed to have 10 m3/d flowrate and installed in Ulaanbaatar, Mongolia. During over 6month operation BOD, COD, TN, TP removal efficiency were measured and operation condition was optimized. In addition, MLSS concentration its internal circulation rate and DO were adjusted properly. BOD, COD showed average 88 perecent of removal and TN and TP achieved 81 percent and 88 percent removal efficency, respectively. Maxium influent concentration of BOD, COD, TN and TP was 214 mg/L, 300 mg/L, 24.3 mg/L and 5 mg/L respectively, which were decreased to 4.1 mg/L, 5.6 mg/L, 1.3 mg/L and 0.15 mg/L by the test system. This study show possibility tham small-scale sewage treatment system could be a useful system for scattered sewage wastewater treatment.

A study on cerebral ischemic model of rat (Effect of 1 hour occlusion of CCA on the distal or proximal MCA occlusioned site) (흰쥐의 허혈성(虛血性) 중풍증(中風證) 모델에 관한 연구(硏究) (중뇌동맥 원 및 근위부폐색에 대한 양측 경동맥 1시간 결찰의 효과))

  • Yoon, Sang-Hyub
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.337-343
    • /
    • 1997
  • With the purpose of producing easily the basal ganglia infarction into Chen's, scerebral ischemic model which is almost cortical infarct made by the ligation of distal part of MCA and 1 hr obliteration of both common carotid arteries in rat, the MCA obstruction was extended between rhinal fissure and olfactory tract with electrocauterization in place of 10-0 silk suture ligation of distal part of MCA. Both original Chen's model and modified Chen's have shown the cortical infarction in dorsolateral & lateral frontoparietal cortex, but not any infarction in basal ganglia. However, the modified Chen's model have shown the effect of average 12% increase in cortical infarct than that of original Chen's model. This experimental results suggest the modified Chen's model can not reduce the blood flow of the lateral lenticulostriatal artery enough to make the basal ganglia infarction and that blood circulation of basal gagglia under its condition is probably being kept partly through the posterior cerebral artery via vertebral artery. Therefore, The follow-up observation on ischemic time lapse would be needed.

  • PDF

Cardiopulmonary Resuscitation: New Concept

  • Lee, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • Cardiopulmonary resuscitation (CPR) is a series of life-saving actions that improve the chances of survival, following cardiac arrest. Successful resuscitation, following cardiac arrest, requires an integrated set of coordinated actions represented by the links in the Chain of Survival. The links include the following: immediate recognition of cardiac arrest and activation of the emergency response system, early CPR with an emphasis on chest compressions, rapid defibrillation, effective advanced life support, and integrated post-cardiac arrest care. The newest development in the CPR guideline is a change in the basic life support sequence of steps from "A-B-C" (Airway, Breathing, Chest compressions) to "C-A-B" (Chest compressions, Airway, Breathing) for adults. Also, "Hands-Only (compression only) CPR" is emphasized for the untrained lay rescuer. On the basis of the strength of the available evidence, there was unanimous support for continuous emphasis on high-quality CPR with compressions of adequate rate and depth, which allows for complete chest recoil, minimizing interruptions in chest compressions and avoiding excessive ventilation. High-quality CPR is the cornerstone of a system of care that can optimize outcomes beyond return of spontaneous circulation (ROSC). There is an increased emphasis on physiologic monitoring to optimize CPR quality, and to detect ROSC. A comprehensive, structured, integrated, multidisciplinary system of care should be implemented in a consistent manner for the treatment of post-cardiac arrest care patients. The return to a prior quality and functional state of health is the ultimate goal of a resuscitation system of care.