• Title/Summary/Keyword: intermittent operation

Search Result 176, Processing Time 0.024 seconds

Corrective surgery of double outlet right ventricle: an analysis of 27 cases (양대동맥 우심실 기시증 [Double Outlet Right Ventricle] 의 전교정술 -27례 분석-)

  • 조재일
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.349-355
    • /
    • 1983
  • Twenty-seven patients with double-outlet right ventricle underwent complete intracardiac repair between 1978 and 1983, June, at Seoul National University Hospital . Although definite aorto-mitral discontinuity was discovered in 20 patients, both great arteries arose wholly or mostly from the right ventricle in all cases. There were 17 cases with subaortic VSD, 6 with subpulmonic, 2 with doubly-committed, and 2 with non-committed VSD. Pulmonary stenosis was present in 21 patients. Intraventricular baffle repair was applied in 23 patients. Three patients required extracardiac conduit to establish continuity between right ventricle and pulmonary artery, and modified Fontan operation was performed in one patient. Over-all mortality rate was 37.0%, but recently 4 of 15 died [26.7%]. One late death occurred from infective endocarditis. Incremental risk factors were small patient size, subpulmonic or non-committed VSD, presence of PS, coronary artery anomalies, associated valvular lesion and other complicated anomalies. However, great artery relationship, restrictive VSD and transannular patch were not risk factors. No instances of complete heart block occurred. Of the survivors, all showed complete or in complete right bundle branch block and in one patient intermittent ventricular tachycardia had developed. The important cause of death was low cardiac output syndrome.

  • PDF

Congenital Sternal Foramen - A case report - (선천성 흉골 공 - 1예 보고 -)

  • Lee, Jong-Ho;Park, Kuhn;Yoon, Hee-Jeoung;Kim, Kyung-Soo;Kwon, Jong-Bum
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.800-802
    • /
    • 2009
  • A 43-year-old male patient visited our hospital because of intermittent chest pain and exertional dyspnea. This patient was diagnosed as suffering with pulmonary stenosis that was caused by muscle hypertrophy of the subpulmonic area, and the diagnosis was made by performing echocardiography and cardiac catheterization. A sternal foramen of the chest wall was found on the operation field. We report here on this case and we also review the relevant literature.

A study on the progressive tool wear and acoustic emission signals in milling process (밀링가공시 발생하는 공구마멸과 AE신호에 관한 연구)

  • 황홍연;이병찬;김광준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1035-1042
    • /
    • 1988
  • The acoustic emission(AE) signal is monitored in milling operation in order to investigate the relationship between the progressive tool wear and the AE signals. A signal processing technique so called time domain averaging(TDA) is presented for the elimination of the influences of the noise imbedded in the periodic signals. The relationship between the progressive tool wear and the AE signals is investigated by varying the cutting speed, feed, depth of cut and the number of insert. From the measured data, it is observed that the averaged level of the AE signal increases at first with the increase of flank wear to a certain critical value, and then stays almost constant or fluctuates with further increase of the flank wear.

The Thronging of Shoals of Squid to Audible underwater Sound (가청 수중음에 대한 오징어 어군의 위집)

  • 서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.3
    • /
    • pp.220-227
    • /
    • 1995
  • An underwater speaker was designed and used as sound source for thronging shoal of squid in squid angling gear operation. The frequency characteristics of the designed speaker was analyzed experimentally and the thronging response of shoals of squid which may be a key parameter for a new sound catching method, was characterized in audible frequency. The field experiment was carried out in the coast of Cheju Island. The results of this study are summarized as follows; 1. Amplitude response of the speaker shows a maximum in their the frequency of 500Hz. 2. The output waveform distortion is not measured in the frequency range of 250~600Hz. 3. A underwater noise of shoals of squid which were thronged by fish lamp in night appeared the center frequency of 300~400Hz. 4. The shoals of squid shows a thronging response, when a manufactured underwater speaker transmits a intermittent audible sound of 300~400Hz in 10m depth of water.

  • PDF

Review on Data Acquisition of Renewable Power Generators (신재생발전기의 데이터 취득방안에 대한 고찰)

  • Lee, Bong-Kil;Kim, Wan-Hong;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.1-20
    • /
    • 2020
  • In accordance with the Government's policy, renewable power generation is expanding very largely. This leads to increasing uncertainty in the power market and power system owing to the intermittent and fluctuating output characteristics of renewable power generators. Data on the acquisition of renewable power generators can be largely classified according to the operation of the power market and power system. Data on the settlement for the payment for the power amount are acquired in the power market, and real-time data for monitoring the status and output of the generators are acquired in the power system. However, renewable power generators operating in the power market have different acquisition cycles depending on the method of communication of the power meter. They acquire data only for settlement purposes and have no real-time data, which requires improvement. In this paper, the acquisition status is reviewed by classifying the data of renewable power generators into settlement and real-time data. In addition, measures and acquisition criteria for real-time data of renewable power generators for improving the acquisition method are proposed.

Rate-capability response of graphite anode materials in advanced energy storage systems: a structural comparison

  • Farooq, Umer;Doh, Chil-Hoon;Pervez, Syed Atif;Kim, Doo-Hun;Lee, Sang-Hoon;Saleem, Mohsin;Sim, Seong-Ju;Choi, Jeong-Hee
    • Carbon letters
    • /
    • v.17 no.1
    • /
    • pp.39-44
    • /
    • 2016
  • The work presented in this report was a detailed comparative study of the electrochemical response exhibited by graphite anodes in Li-ion batteries having different physical features. A comprehensive morphological and physical characterization was carried out for these graphite samples via X-ray diffraction and scanning electron microscopy. Later, the electrochemical performance was analyzed using galvanostatic charge/discharge testing and the galvanostatic intermittent titration technique for these graphite samples as negative electrode materials in battery operation. The results demonstrated that a material having a higher crystalline order exhibits enhanced electrochemical properties when evaluated in terms of rate-capability performance. All these materials were investigated at high C-rates ranging from 0.1C up to 10C. Such improved response was attributed to the crystalline morphology providing short layers, which facilitate rapid Li+ ions diffusivity and electron transport during the course of battery operation. The values obtained for the electrical conductivity of these graphite anodes support this possible explanation.

Effects of load variation on a Kaplan turbine runner

  • Amiri, K.;Mulu, B.;Cervantes, M.J.;Raisee, M.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.2
    • /
    • pp.182-193
    • /
    • 2016
  • Introduction of intermittent electricity production systems like wind and solar power to electricity market together with the deregulation of electricity markets resulted in numerous start/stops, load variations and off-design operation of water turbines. Hydraulic turbines suffer from the varying loads exerted on their stationary and rotating parts during load variations since they are not designed for such operating conditions. Investigations on part load operation of single regulated turbines, i.e., Francis and propeller, proved the formation of a rotating vortex rope (RVR) in the draft tube. The RVR induces pressure pulsations in the axial and rotating directions called plunging and rotating modes, respectively. This results in oscillating forces with two different frequencies on the runner blades, bearings and other rotating parts of the turbine. This study investigates the effect of transient operations on the pressure fluctuations exerted on the runner and mechanism of the RVR formation/mitigation. Draft tube and runner blades of the Porjus U9 model, a Kaplan turbine, were equipped with pressure sensors for this purpose. The model was run in off-cam mode during different load variations. The results showed that the transients between the best efficiency point and the high load occurs in a smooth way. However, during transitions to the part load a RVR forms in the draft tube which induces high level of fluctuations with two frequencies on the runner; plunging and rotating mode. Formation of the RVR during the load rejections coincides with sudden pressure change on the runner while its mitigation occurs in a smooth way.

Development of Stem-cutting Transplanter for Short-term Rotation Coppice (단기순환림 생산을 위한 삽목 이식기 개발)

  • Kim, Dong-Hwa;Kim, Dae-Cheol;Kim, Sang-Hun;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.37-45
    • /
    • 2010
  • Since SRC (Short-term Rotation Coppice) such as poplar and willow can be harvested in three years, they are known to be a potential forest biomass as fuel for a power plant. The production system including transplanting and harvesting is, however, necessary to be mechanized because such a biomass should be handled in a massive volumetric size. A pull-type stem-cutting transplanter was developed in the research as the first step to realize the production of SRC. A needle-like transplanting device pushes a stem-cutting into the prepared soil bed by a pneumatic cylinder, and another device firms soil around a stem-cutting transplanted. Since this is an intermittent operation, it was necessary to develop a zero horizontal velocity mechanism which enabled only the transplanting needle part to continue a zero horizontal movement relative to the ground during the transplanting operation even when the tractor kept moving forward. The 2-row transplanter can transplant stem-cuttings at the rate of 6.5 seconds per row without missing a single attempt. The planting depth and distance were well maintained and controlled. Their CVs were between 2.1~3.4% and 0.87~1.7% for the depth and the distance, respectively. Although, the transplanted stem-cuttings tended to lean outward from the back-view and forward from the side view, they were planted within the range of $3^{\circ}$ from the upright position.

Optimal Clustering of Energy Storage System for Frequency Regulation Service Considering Life Degradation (수명감소를 고려한 주파수 조정용 에너지저장장치의 최적 클러스터링)

  • Kim, Wook-Won;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.555-560
    • /
    • 2016
  • Recently, many countries have placed great attention on energy security and climate changes. Governments are promoting the construction of renewable energy projects with regulatory support in Korea. Despite an increasing penetration of renewable resources, however, the photovoltaic and wind power are underutilized due to the endemic problems such as difficulties of output control and intermittent output. The Energy Storage System (ESS) is proposed as a good solution for solving the problems and has been studied in both the private business and the government. However, because of inefficient aspects, the research has been carried out for improving high costs and a small capacity. In addition, the ESS is currently installed for using only one purpose which is frequency regulation or transmission congestion relief such that has an economic limitation. Therefore, methods which are becoming economically justifiable to increase the penetration of the ESS is required. Thus, this paper presents in terms of operation efficiency to improve economic feasibility of the ESS currently used. mainly, there are two aspects for the operation efficiency. Firstly, it is intended to improve the utilization rate through a process that can utilize the ESS for various purposes. It is necessary to be able to use for other purposes by classifying and clustering for increasing the efficiency of availability. The clustering method is proposed to conduct the grouping the ESS. Especially, it is proposed to utilize ESS for frequency regulation service which is the one of ancillary services in the power system. Through case studies, it is confirmed to secure the necessary resources by clustering small size ESS.

Surgical Treatment of Aortoiliac Arterial Occlusion: Report of 2 Cases (대동맥하단부-장골동맥의 급,만성 폐쇄성 동맥질환 2례)

  • 마중성
    • Journal of Chest Surgery
    • /
    • v.5 no.1
    • /
    • pp.19-24
    • /
    • 1972
  • The recent development of cardiovascular surgery as well as aortoarteriogaphy has been established excellent operative result with great aid of limb-salvage. However, less consideration or less experience still exists on the regard of vascular accident and vascular disease, as well as vascular surgery in Korea. During the last 13 years, we experienced only two cases of aorto-iliac occlusion,acute and chronic, regardless of having had more than 300 cases of mitral valvotomy and gradual increasing tendency of arteriosclerosis and hypertension in Korea. Therefore it is noteworthy to report the cases in order to promote the consideration for vascular surgery. Case 1; 52 year old female who had 20 years history of mitral stenosis with uricular fibrillation and received medical treatment for recent 1 year in the medical department. 10 days before admission, acute saddle emboli developed and 15 days after the onset, embolectomy through both common femoral arteries on the groin and abdominal approach was made. The progression of emboll to the right popliteal bifurcation was found by arteriography on operating table and retrograde flushing with heparin solution by the polyethylene catheter inserted through posterior tibial artery. The operation was successful, but 9 hours after operation sudden death occurred. Considering this case, first, mitral valvotomy already before might prevent peripheral embolizatlon, secondarily, the more early detection and surgery might also prevent the progression of emboli. Thirdly, although preoperative or postoperatlve heparinization is controversial for mitraI stenosis, heparinization might prevent additional emboli to vital organs in this case Cases 2; 66 year old female who had 4 years history of left hip and calf intermittent claudication and has had rest pain, inability to walk and ischemic necrosis on the the left leg since last 3 months prior to admission to the orthopedic department under the suspicion of herniated disc. Absence of pulsation on the groin and aortography evidenced aortoillac occlusion predominantly on the left side. Thromboendarterectomy was made and the operative result was successful with absence of claudication, healing of ulcer and aortographic patency of occlusive site. This chronic occlusion is considered to result from arteriosclerosis in origin with the evidence of moderate hypertension, x-ray evidence of calcified plaque on the aortic knob and operative finding of palpable plaques.

  • PDF