• Title/Summary/Keyword: interior-point method

Search Result 286, Processing Time 0.026 seconds

Evaluation of Geometric Error Sources for Terrestrial Laser Scanner

  • Lee, Ji Sang;Hong, Seung Hwan;Park, Il Suk;Cho, Hyoung Sig;Sohn, Hong Gyoo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.2
    • /
    • pp.79-87
    • /
    • 2016
  • As 3D geospatial information is demanded, terrestrial laser scanners which can obtain 3D model of objects have been applied in various fields such as Building Information Modeling (BIM), structural analysis, and disaster management. To acquire precise data, performance evaluation of a terrestrial laser scanner must be conducted. While existing 3D surveying equipment like a total station has a standard method for performance evaluation, a terrestrial laser scanner evaluation technique for users is not established. This paper categorizes and analyzes error sources which generally occur in terrestrial laser scanning. In addition to the prior researches about categorizing error sources of terrestrial Laser scanning, this paper evaluates the error sources by the actual field tests for the smooth in-situ applications.The error factors in terrestrial laser scanning are categorized into interior error caused by mechanical errors in a terrestrial laser scanner and exterior errors affected by scanning geometry and target property. Each error sources were evaluated by simulation and actual experiments. The 3D coordinates of observed target can be distortedby the biases in distance and rotation measurement in scanning system. In particular, the exterior factors caused significant geometric errors in observed point cloud. The noise points can be generated by steep incidence angle, mixed-pixel and crosstalk. In using terrestrial laser scanner, elaborate scanning plan and proper post processing are required to obtain valid and accurate 3D spatial information.

Study on the Acupuncture in Hyungsang (형장침법 연구)

  • Kang Kyung Hwa;Kim Kyung Chul;Baik Geun Gi;Lee Yong Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1157-1176
    • /
    • 2003
  • The following conclusions are induced from a study on the acupuncture therapy depending on hyungsang of the persons. The study is made on the basis of 'Internal classic (內經)& and &Clinical Lectures by Dr. Jeesan&. The acupuncture originated from the treatment of spasm with numbness in the southern area. The acupuncture is basically a remedy for the exterior disease of meridian but also it can be a cure for the interior disease of Jang and obstinate disease with accurate method. Three mechanisms of acupuncture are described in 'Internal classic'. The first is to make meridian circulate smoothly. The second is to regulate Ki and Hyul. The third is to regulate points through which the meridian-Ki goes in and out smoothly or adversely. There are two ways of acupuncture in 'Internal classic'. One is based on pulse and symptom and the other on the Hyungsang. The former is more generally used therapy, to which depletion method, Asi point method(阿是穴 療法), Inyoung-kigu pulse comparison method (人迎氣口脈法) and method depending on jang-bu disease belong. Acupuncture is done on Su points(輸穴) and back-su point(背兪穴) in case of jang-disease. In case of bu-disease, the treatment is done on Hap points(合穴) and Mo-points(募穴). The latter includes two methods; one according to invariable Hyungsang. And the other to variable Hyungsang. The method of acupuncture according to invariable Hyungsang usually selects Won-points(原穴). Different Hyungsang requires different method of acupuncture; In case of Dam type, the acupuncture is mainly practiced on four-Kwan points with reinforcing and reducing methods achieved by the direction of the needle tip pointing to. In case of Bangkwang type, the acupuncture is usually done on Jungwan(中脘) and Poongyung(豊隆) with reinforcing and reducing methods by means of respiration. In case of female, more effective are the acupoints on the right and lateral parts of the body selected on the basis of five su-points of the twelve meridians matching the heavenly stems and earthly branches. In case of male, more effective are the acupoints on the left, front and rear parts of the eight extra meridians. In case of acupuncture to the person with Hyungsang of five jang and six bu, each person's intrinsic Hyung, color, pulse, must be observed. Because symptoms of jang-bu disease also must be checked up. Acupuncture is done on the Won-points of the meridians related to the jang and bu where the disease starts. The disease of five jang is so obstinate that it requires both of medication and acupuncture for a long time. In case of acupuncture to the person with Hyungsang of animal types, diagnosis is made on the basis of shape, temper, function and color. And the treatment is given on the Won-points of corresponding exterior and interior meridians. For the fish type, the acupuncture is done on the kidney meridian of foot-soyin and the urinary bladder of foot-taiyang. For the bird type, on the heart meridian of hand-soyin, the pericardium meridian of hand-gualyin, and the small intestine meridian of hand-taiyang For the deer type, on the liver meridian of foot-gualyin and the gallbladder meridian of foot-soyang. For the turtle type, on the lung meridian of hand-taiyin and the large intestine meridian of hand-yangmyung.

EPAR V2.0: AUTOMATED MONITORING AND VISUALIZATION OF POTENTIAL AREAS FOR BUILDING RETROFIT USING THERMAL CAMERAS AND COMPUTATIONAL FLUID DYNAMICS (CFD) MODELS

  • Youngjib Ham;Mani Golparvar-Fard
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.279-286
    • /
    • 2013
  • This paper introduces a new method for identification of building energy performance problems. The presented method is based on automated analysis and visualization of deviations between actual and expected energy performance of the building using EPAR (Energy Performance Augmented Reality) models. For generating EPAR models, during building inspections, energy auditors collect a large number of digital and thermal imagery using a consumer-level single thermal camera that has a built-in digital lens. Based on a pipeline of image-based 3D reconstruction algorithms built on GPU and multi-core CPU architecture, 3D geometrical and thermal point cloud models of the building under inspection are automatically generated and integrated. Then, the resulting actual 3D spatio-thermal model and the expected energy performance model simulated using computational fluid dynamics (CFD) analysis are superimposed within an augmented reality environment. Based on the resulting EPAR models which jointly visualize the actual and expected energy performance of the building under inspection, two new algorithms are introduced for quick and reliable identification of potential performance problems: 1) 3D thermal mesh modeling using k-d trees and nearest neighbor searching to automate calculation of temperature deviations; and 2) automated visualization of performance deviations using a metaphor based on traffic light colors. The proposed EPAR v2.0 modeling method is validated on several interior locations of a residential building and an instructional facility. Our empirical observations show that the automated energy performance analysis using EPAR models enables performance deviations to be rapidly and accurately identified. The visualization of performance deviations in 3D enables auditors to easily identify potential building performance problems. Rather than manually analyzing thermal imagery, auditors can focus on other important tasks such as evaluating possible remedial alternatives.

  • PDF

Reliability Prediction of Failure Modes due to Pressure in Solid Rocket Case (고체로켓 케이스 내압파열 고장모드의 신뢰도예측)

  • Kim, Dong-Seong;Yoo, Min-Young;Kim, Hee-Seong;Choi, Joo-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.6
    • /
    • pp.635-642
    • /
    • 2014
  • In this paper, an efficient technique is developed to predict failure probability of three failure modes(case rupture, fracture and bolt breakage) related to solid rocket motor case due to the inner pressure during the mission flight. The overall procedure consists of the steps: 1) design parameters affecting the case failure are identified and their uncertainties are modelled by probability distribution, 2) combustion analysis in the interior of the case is carried out to obtain maximum expected operating pressure(MEOP), 3) stress and other structural performances are evaluated by finite element analysis(FEA), and 4) failure probabilities are calculated for the above mentioned failure modes. Axi-symmetric assumption for FEA is employed for simplification while contact between bolted joint is accounted for. Efficient procedure is developed to evaluate failure probability which consists of finding first an Most Probable Failure Point(MPP) using First-Order Reliability Method(FORM), next making a response surface model around the MPP using Latin Hypercube Sampling(LHS), and finally calculating failure probability by employing Importance Sampling.

Studies on Press Drying and Dynamic Elastic Modulus of Plywood Treated with Boric Acid (붕산처리(硼酸處理) 합판(合板)의 열판건조(熱板乾燥) 및 동적(動的) 탄성율(彈性率)에 관(關)한 연구(硏究))

  • Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.56-67
    • /
    • 1987
  • Plywoods used for construction as a decorative interior material are inflammable and can make fire accidents, causing destruction of human life and property. Therefore, it is indeed required to make fire-retardant treated plywood. In this study, 3.7mm yellow meranti plywoods were soaked in 18% boric acid solutions and tap water by hot-cold bath for 1/2, 2/2, 4/2, 6/2 hours and redrying of treated plywoods was carried out by press drying at the platen temperature of 110, 130, 160, $180^{\circ}C$ and then it was conducted to investigate solution absorption, drying rates, dynamic young's modulus. specific gravity and fire-retardant factors such as burning point, flame spread length. flame exhausted time, back side carbonized area and weight loss by treating time, treating solutions and platen temperature. The results are as follows; 1. When plywood was impregnated with the hot bath temperature of $70^{\circ}C$ for 1. 2, 4, 6 hours and the cold bath temperature of $15^{\circ}C$ for 2 hours respectively, retentions of boric acid were 1.565, l.597, 1.643, 1.709kg/$(30cm)^3$ and all of them exceeded the minimum retention [1.125kg/$(30cm)^3$] even in the shortest treatment. 2. In hot-cold bath method for 1/2 hours, the drying rates of treated plywood remarkably increased with the extension of platen temperature of 110, 130, 160, $180^{\circ}C$ and the values of boric acid treated plywood were 5.900, 10.196, 45.42, 54.958m.c%/min and the values of water treated plywood were 6.014, 12.373, 46.520, 55.730m.c%/min and drying rates of water treated plywood were faster than those of boric acid treated plywood. 3. The values of boric acid treated plywoods in dynamic young's modulus were widely higher than those of water treated plywoods. And it can be observed that there were highly significant differences for treating time between dynamic young's modulus, and the values of boric acid plywoods increased with the extension of treating time but on the contrary water treated plywoods were decreased values with prolonged time 4. It was observed that there were highly significant differences for platen temperature between dynamic young's modulus. When the values of water treated plywoods in dyna nic young's modulus were abruptly decreased according to the rise of platen temperature. boric acid treated plywoods showed rather increased values at $160^{\circ}C$ of platen temperature. And in 2- way interactions, there were also highly significant for dynamic young's modulus between treating time x treating solutions and platen temperature x treating solutions. 5. Correlation coefficients of fire-retardant factors were shown in table 5. It could be recognized that there were close correlations between the treating solutions and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, but there was no correlation between fire-retardant factors and treating time and platen temperature. 6. From table 6, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carbonized area, weight loss between treating solutions. And in 2-way interactions, there were highly significant for burning point, flame spread length, weight loss between treating time $\times$ treating solutions.

  • PDF

A Comparative Study of the Expantionist Architectural Concept in Post-Modern Museums -focused on Neue Staatsgalerie Stuttgart and Stadtisches Museum Abteiberg Monchengladback in Germany- (포스트모던 미술관 건축의 확장된 건축개념에 관한비교연구 -독일 스튜트가르트 국립미술관 신관과 묀헨글라드바하 시립미술관을 중심으로-)

  • 김명옥
    • Korean Institute of Interior Design Journal
    • /
    • no.14
    • /
    • pp.82-89
    • /
    • 1998
  • During the boom of museum building in the 1970s-80s two museum wee erected in Germany. They are James Stirling's Neue Stattsgalerie Stuttgart and hans Hollein's Stadtisches Museum Abteiberg Monchengladbach, These two museums share the folowing point of similarity : Stirling's Neue Stattsgalerie Stuttgart and Hollein's Staditisches Museum Abetiberg Monchenbladbach both manifest the conditions of the times in light of their respective cities' local characters and historical contexts without being bound to traditional formality. Stirling and Hollein attempted to grasp the meaning of the 기nuseum as a city in miniature." Taking into account the t two museums’s territorial characteristics of being situated on a slope, both Stirling and Hollein made the walker to pass t through their building complex and introduced the concept of a public square within them. As a result, the museums are not j just two large buildings but are architecture composed of a collage of various structures. S Stirling’s architecture employs the method of attaching additional elements on top of basic constituents, which is suggestive '||'&'||'#61551; of the historical fragment from Shinkel's Altes Museum. On the other hand, Hollein applies a collage-style method as if he w were doing urban planning, maintaining the distinctiveness of each of the various forms and materials of buildings. T The object style buildings of the two museums actively demonstrate the contrast of double meaning to represent the a ambiguous and multifarious characteristics of the modern times. Stirling explores the theme of opposition and coexistence in h his Neue Stattsgalerie Stuttgart by placing a series of opposing concepts, such as the past and present and histor${\gamma}$ and t technology, in one space. Thereby, the contradiction and its appeal are manifested. Hollein made use of the visual illusion and c contradiction in alluding to the irony of the modern reality induced by nature and culture and history and technology. F For the above reasons and methods, James Stirling ’ s Neue Stattsgalerie Stuttgart allowed the penetration of art into daily l life and became the general public’s favored museum for its free and unrestrained environment. Likewise, Hans Hollein’s S Stadtisches Museum Abteiberg Moncbengladbach contribute to the development of museum function as it an expression of art i in the form of a complex piece of scupture on its own.ts own.

  • PDF

A TOA Shortest Distance Algorithm for Estimating Mobile Location (모바일 위치추정을 위한 TOA 최단거리 알고리즘)

  • Pradhan, Sajina;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1883-1890
    • /
    • 2013
  • Location detection technology (LDT) is one of the core techniques for location based service (LBS) in wireless communication for improving resource management and quality of services. The location of a mobile station (MS) is estimated using the time of arrival (TOA) technique based on three circles with centers corresponding to coordinates of three base stations (BSs) and radius corresponding to distances between MS and BSs. For accurately estimating the location of MS, three circles should meet at a point for the trilateration method, but they generally do not meet a point because the radius is increased depending on the number of time delay for estimating the distance between MS and BS and the carrier frequency. The increased three circles intersect at six points and the three intersection points among them should be generally placed close to coordinate of the location for the specific MS. In this paper, we propose the shortest distance algorithm for TOA trilateration method, to select three interior intersection points from entire six points. The proposed approach selects three intersection points with the shortest distances between coordinates of MS and intersection points and determines the averaged coordinate of the selected three points, as the location of the specific MS. We demonstrate the performance of the proposed algorithm using a typical computer simulation example.

Attractiveness Valuation of Phenomenal Architectural Aesthetic by Mixing the Fuzzy Logic with Contingent Valuation - Availing the Use Fares of Facility within Nodle Islet Cultural Center as Valuation Scale - (퍼지논리와 가상가치법 혼합을 통한 현상적 건축미의 매력가치 - 노들섬 문화센터 시설이용료를 가치 척도로 -)

  • Lee, Dong-Joo;Ko, Eun-Hyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.3-10
    • /
    • 2018
  • The purpose of this study is to estimate the attractiveness value according to the preference level on architectural aesthetic. This research starts from the concept that aesthetic is phenomenon and from the viewpoint of 'attraction value' which affects goods. Interactive internet surveys were conducted for 500 citizens of Seoul metropolitan city who are potential users of the Nodle Islet Cultural Center. Based on the scenarios and questionnaires with fuzzy models, we have examined the evaluation of architectural aesthetic and monetary willing-to-payment, and estimated the economic value by preference level of architectural aesthetic through linear regression analysis. The main results of the study are as follows: First, the economic value of the Nodle Islet Cultural Center was estimated at ?15,683.43/person. Residents of Seoul metropolitan city were willing to accept the increase in the above-mentioned amount of the facility fares when their preferred works (average 86.81 points) were constructed. (P <0/05) Second, it is confirmed that the economic value increases dramatically as the preference level of architectural aesthetic increases. Third, it is presumed that the infinite valuation of architectural aesthetic and the problem of free riding coexist in the estimation of economic valuation of architectural aesthetic for public buildings. Fourth, by mixing the fuzzy logic with contingent valuation method, starting point bias and no response biases that happened in contingent valuation could be disappeared. bias elimination must be considered seriously because another bias could be happened in full process of the research. The results of this study will serve as a basis for spreading architectural aesthetic value-oriented research from the vague and obscure aesthetic-centered discussion on the existing architectural aesthetic. In addition, it will be an opportunity to draw institutional application and utilization strategy of architectural aesthetic through architectural aesthetic value research.

Core${\cdot}$Quality${\cdot}$Basic Service Factors of Family Restaurants and Differentiation Strategy for Customer Service Management (패밀리 레스토랑의 핵심${\cdot}$고품질${\cdot}$기본서비스 요인과 요인 별 고객관리 차별화 전략에 관한 연구)

  • Park, Jung-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.23 no.2
    • /
    • pp.184-193
    • /
    • 2008
  • The purpose of this study was to determine the detailed customer satisfaction and dissatisfaction factors of family restaurants in Korea, and to then classify the factors into 3 groups, inlcuding core service, quality service, and basic service. ‘Core service’ represents the critical factors that generate both satisfaction and dissatisfaction; ‘quality service’ generates only satisfaction; and ‘basic service’ generates only dissatisfaction. This categorization is based on Herzberg’s motivation-hygiene theory (1976) as well as Cadotte & Turgeon (1988). Based on the characteristics of the three groups, differentiation strategies in managing customer service were suggested to the family restaurant managers. A qualitative research method, termed the critical incident technique (CIT), was used in the study. This method helps researchers find new factors or attributes by grouping key issues from the anecdotes (critical incidents) and then categorizing common factors from the key issues. This research categorized key satisfiers and dissatisfiers into 33 factors, which were from 402 critical incidents described by 261 respondents. Eleven factors (response to service failures, food taste and quality, attention paid to customers, coupon/mileage point/discount card, customer’s ordinary requests, waiting, food diversity, food price, facility sanitation, checking out, customer’s special requests) were classified into core service, which required maximum management not regarding the level of customer satisfaction. Six factors (employee attitude, event, education and explanation, complementary food, customer’s mistakes, attention paid to children) were classified into quality service, which required differentiation strategy management. Finally, nine factors (speed of food service, employee’s mistakes, food sanitation, atmosphere and interior, seating, forcing orders, parking, other customers, reservations) were classified into basic service, which required minimum management at the level of the industry standards.

A Study on the Development and Dielectric Properties of Insulating Materials for Super-Conductor -For Matrix of Composite Materials- (초전도체 절연용 재료의 전기적 절연 특성과 개발에 관한 연구-복합 재료의 매트릭스에 대하여-)

  • 조정수;최세원;김종경;이규철;이종호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.7
    • /
    • pp.511-523
    • /
    • 1989
  • This paper investigates physical properties, the electrical and mechanical characteristics of the epoxy resin with different curing methods and postcuring conditions at room temperature or cryogenic temperature (LN2). According to the results in this paper, first, it is found that the physical properties, electrical and mechanical characteristics of the epoxy resin are largely affected by the interior reaction temperature on the curing. Thus, in the fabrication of the sample, several excellent characteristics of the sample are obtained by controlling the interior reaction temperature of the epoxy resin. Second, the sample having optimal electrical and mechanical characteristics is obtained for the repetitive post-curing method at 100c in view point of the post-curing conditions of the epoxy resin. Third, it appears that tan and characteristics at LN2 temperature are about half of those at room temperature. Fourth, it appears that the dielectric strength of the epoxy resin at LN2 temperature is higher by about 0.6-1.0 MV/cm than that at room temperature. The heat-aging of the epoxy resin due to the micro-defect and excess fever-movement have been noticed to affect dielectric strength at LN2 temperature more significantly than at room temperature.