• Title/Summary/Keyword: interior fire protection design

Search Result 13, Processing Time 0.022 seconds

A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses (다중이용업소 실내마감재료 사용기준에 관한 연구)

  • Kim, Yong-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

Boryeong Fire Plant Museum Project (보령화력발전소 홍보관 계획)

  • Lee, Moo-Sang;Jung, Do-Kuen
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.77-78
    • /
    • 2007
  • This project has been designed for people to experience and understand the process, importance and benefit of coal fire plants. As the biggest and first typical Korean fire plant using coal, Boryeong fire plant has had important roll for the Korean industries. Even so, people has had wrong prejudice for the fire plant in terms of environmental protection. To do these kind of rolls, this museum has been designed with theme, "Boryeong fire plant mating symbiotic relationship between nature, human and technologies." The space was zoned with five major themes: i. circulation of energy in nature, ii. electric power and eco-fire plant, iii. future energy, iv roll for future of environment, v. Korea as the leading energy industry. The design has been developed focused on spatial experiences to make 'Design Sequence' with linear circulations haying several important destinations. The interior has been finished with minimal color and materials projected by big sized movie and various LED movie system. Concept of appordance has been used to make interactive experiences between exhibits and visitors.

  • PDF

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

A Study on the Survey of Each Country's Standards to Prevent Flashover of Housing Building (주거시설의 플래시오버 방지를 위한 각국의 내장재 기준 조사에 관한 연구)

  • Hun, Ye-Rim;Kim, Yoon-Seong;Lee, Byeong-Heun;Jin, Seung-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.44-45
    • /
    • 2021
  • In Korea, the risk of fire in buildings is increasing. Therefore, efforts are needed to reduce casualties and property damage. Accordingly, it is important to limit the flashover so that the fire inside the building does not expand to the outside. Flashover refers to the generation of upward airflow after the fire in the compartment, and when combustible gas accumulates in the upper part of the fire chamber and reaches about 500℃, explosive expansion combustion occurs inside the compartment. This can suppress flashover due to limitations on building interior materials. To this end, internal limitations are being implemented at home and abroad through standards related to internal materials. In this paper, we intend to secure basic data on domestic fire safety design by comparing domestic and foreign standards and reviewing the Japanese housing interior design manual.

  • PDF

A Study on Improvement of Discharge Pressure Measurement of Indoor Fire Hydrant System (옥내소화전설비의 방수압 측정 개선에 관한 연구)

  • Min, Se-Hong;Jeong, Sang-Ho
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.67-72
    • /
    • 2012
  • Indoor fire hydrant facilities and sprinkler system applied to the initial fire suppression for buildings' interior fire are pivotal roles in extinguishing the fire in the early stage. The roof shapes of recent buildings combined with distinctive local culture and design are being constructed. Distinctive roof forms, i.e. gable roof buildings are planned and built, View point planning with the roof gardens also restricts measurement of the discharge pressure on the indoor fire hydrant, It is too narrow to gauge the water discharge pressure with deploying up to 5 water hoses. To resolve these problems improvement for the efficient management of indoor fire hydrant system and the effective early stage flame extinguishment is suggested.

A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design - (미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 -)

  • Kim, Young-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

A Study on the Safety-related Criteria for the Interior Space Planning, Facilities and Fire-fighting Equipment in Child Care Centers (보육시설의 실내공간계획 및 설비와 소방설비의 안전성 관련 기준에 대한 연구)

  • Rhee, Jisook
    • Journal of Families and Better Life
    • /
    • v.31 no.6
    • /
    • pp.39-51
    • /
    • 2013
  • Because of the increasing demand for day care centers, The Korean government has enforced childcare accreditation. The government has created the evaluation certification system for child care facilities. But the system includes variable items, and the physical rules are not sufficient for ensuring security and quality amenities. So this study, through literature search, examined the rules of Child Care Centers in the U.S. and compared them with those in Korea focusing on the provision of security and amenities. The standards found in 4 U.S. states were investigated, and the results are as follows. The rule pertaining to the size of indoor activity spaces in C.C.C. allows the spaces to be smaller in Korea than in the U.S. There is no specific criterion for infants and toddlers in our standard. When comparing the standards of Korea with those of the United States, Korea's standards do not state specific rules about child care facilities such as indoor furniture, finishes and space planning. Additionally, the binding force ensuring compliance with the standards of physical facilities is weak. Thus, the ratings of child care standards for the physical environment should be presented in detail. And if a center does not comply with the criteria, stronger penalties will have to be imposed.

Methods to Improve the Design of Household Fire Extinguishers through an Empirical Analysis of Consumer Compatibility (소비자의 적합성 실증분석을 통한 가정용 소화기의 디자인 개선방안)

  • Lee, Sung-Woo
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.58-66
    • /
    • 2020
  • Households are categorized as exceptions in the Fire Services Act; oftentimes, the 'Golden Time' is missed at the early stages of a fire, resulting in loss of life. As such, due to the high number of deaths caused by household fires, the Korean government amended the Fire Services Act to make it mandatory for all detached houses to be equipped with a fire extinguisher from 2017 onwards. Only 34.8% of households were properly equipped with a fire extinguisher, according to the 2018 factual survey on fire extinguishing facilities in households conducted by the Fire Department. Fire extinguishers are crucial in case of fire but many households avoid them because they are red and have a rough aesthetic, which does not suit the household environment. There is now a need for diverse simple fire extinguisher designs so that they can be used as interior décor in the household in the day-to-day while being available for putting out a fire when necessary. If fire extinguishers have designs that go well with any household space like other decorative ornaments, this will greatly increase consumers' motivation to purchase them. It is greatly anticipated that various companies will work on developing designs for fire extinguishers to commercialize them for households in the future.