• 제목/요약/키워드: interferometers

검색결과 95건 처리시간 0.028초

Optical Multi-Channel Intensity Interferometry - or: How To Resolve O-Stars in the Magellanic Clouds

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.111-111
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown--Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25,000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer of the 1970s when resolving. Our approach, based on spectrally resolved light, permits the construction of large optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometers are able to spatially resolve main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars; (ii) mass-radius relationships of compact stellar remnants; (iii) stellar rotation; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields; (v) the structure and evolution of multiple stars; (vi) direct measurements of interstellar distances; (vii) the physics of gas accretion onto supermassive black holes; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

  • PDF

이중 패브리-페로 간섭계에 대한 분광학적 분석방법 (Spectroscopic methods for the analysis of tandem fabry-perot interferometer)

  • 이석목
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.231-237
    • /
    • 1994
  • 이중 패브리-페로 간섭계의 구조분석에 대한 분광학적인 방법을 제시하였다. 수 십 GHz의 차이가 있는 두 가지의 진동수의 광선을 이용하여 각 간섭계의 공동거리와 간섭계간의 필요조건에 대한 정밀도 및 측정방법 등에 대하여 이론적으로 조사하였으며 그 결과를 실험으로 확인하였다.

  • PDF

고정밀 광학계 측정을 위한 점회절 간섭계의 특성 연구 (Characteristics of Point-diffraction Interferometer for certification of high-precision optical system)

  • 이경희;최영욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.138-139
    • /
    • 2007
  • The use of conventional Twyman and Fizeau interferometers inevitably fails in testing high precision optics because of errors always existing in reference elements producing the reference wavefront. Therefore it is necessary to apply to this task the interferometers of a radically new type, which are able to produce perfect reference wavefront with the help of light diffraction by a small obstacle or pinhole. In this paper new theoretical approaches and schematics of point diffraction interferometers are considered in detail with paying attention to constructive reliability. Such interferometers do not use reference optical surfaces and readily provide adequate estimation of errors and aberrations value of 0.01 wavelengths.

  • PDF

High-order Reduced Radial Zernike Polynomials for Modal Reconstruction of Wavefront Aberrations in Radial Shearing Interferometers

  • Tien Dung Vu;Quang Huy Vu;Joohyung Lee
    • Current Optics and Photonics
    • /
    • 제7권6호
    • /
    • pp.692-700
    • /
    • 2023
  • We present a method for improving the accuracy of the modal wavefront reconstruction in the radial shearing interferometers (RSIs). Our approach involves expanding the reduced radial terms of Zernike polynomials to high-order, which enables more precise reconstruction of the wavefront aberrations with high-spatial frequency. We expanded the reduced polynomials up to infinite order with symbolic variables of the radius, shearing amount, and transformation matrix elements. For the simulation of the modal wavefront reconstruction, we generated a target wavefront subsequently, magnified and measured wavefronts were generated. To validate the effectiveness of the high-order Zernike polynomials, we applied both low- and high-order polynomials to the wavefront reconstruction process. Consequently, the peak-to-valley (PV) and RMS errors notably decreased with values of 0.011λ and 0.001λ, respectively, as the order of the radial Zernike polynomial increased.

OPTICAL MULTI-CHANNEL INTENSITY INTERFEROMETRY - OR: HOW TO RESOLVE O-STARS IN THE MAGELLANIC CLOUDS

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • 천문학회지
    • /
    • 제47권6호
    • /
    • pp.235-253
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown-Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions; its use in astronomy was abandoned in the 1970s because of low sensitivity. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25 000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer. This is made possible by (i) using avalanche photodiodes (APD) as light detectors, (ii) distributing the light received from the source over multiple independent spectral channels, and (iii) use of arrays composed of multiple large light collectors. Our approach permits the construction of large (with baselines ranging from few kilometers to intercontinental distances) optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometer designs are able to achieve limiting R-band magnitudes as good as $m_R{\approx}14$, sufficient for spatially resolved observations of main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars, via direct measurements of stellar angular sizes; (ii) mass-radius relationships of compact stellar remnants, via direct measurements of the angular sizes of white dwarfs; (iii) stellar rotation, via observations of rotation flattening and surface gravity darkening; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields, via observations of dark and bright starspots; (v) the structure and evolution of multiple stars, via mapping of the companion stars and of accretion flows in interacting binaries; (vi) direct measurements of interstellar distances, derived from angular diameters of stars or via the interferometric Baade-Wesselink method; (vii) the physics of gas accretion onto supermassive black holes, via resolved observations of the central engines of luminous active galactic nuclei; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

중력렌즈 사건의 측성적 시차효과 검출에 대한 연구 (Astrometric Detectability of Parallax Effect in Gravitational Microlensing Events)

  • 한정호
    • 천문학논총
    • /
    • 제15권1호
    • /
    • pp.15-19
    • /
    • 2000
  • The lens mass determined from the photometrically obtained Einstein time scale suffers from large uncertainty due to the lens parameter degeneracy. The uncertainty can be substantially reduced if the mass is determined from the lens proper motion obtained from astrometric measurements of the source image centroid shifts, ${\delta}{\theta}_c$, by using high precision interferometers from space-based platform such as the Space Interferometry Mission (SIM), and ground-based interferometers soon available on several 8-10m class telescopes. However, for the complete resolution of the lens parameter degeneracy it is required to determine the lens parallax by measuring the parallax-induced deviations in the centroid shifts trajectory, ${\Delta}{\delta}{\theta}_c$ aloe. In this paper, we investigate the detectabilities of ${\delta}{\theta}_c$ and ${\Delta}{\delta}{\theta}_c$ by determining the distributions of the maximum centroid shifts, $f({\delta}{\theta}_{c,max})$, and the average maximum deviations, $(<{\Delta}{\delta}_{c,max}>)$, for different types of Galactic microlensing events caused by various masses. From this investigation, we find that as long as source stars are bright enough for astrometric observations it is expected that $f({\delta}{\theta}_c)$ for most events caused by lenses with masses greater than 0.1 $M_\bigodot$ regardless of the event types can be easily detected from observations by using not only the SIM (with a detection threshold but also the ${\delta}{\theta}_{th}\;\~3{\mu}as)$ but also the ground-based interferometers $(with\;{\delta}{\theta}_{th}\;\~3{\mu}as)$. However, from ground-based observations, it will be difficult to detect ${\Delta}{\delta}{\theta}_c$ for most Galactic bulge self-lensing events, and the detection will be restricted only for small fractions of disk-bulge and halo-LMC events for which the deviations are relatively large. From observations by using the SIM, on the other hand, detecting ${\Delta}{\delta}{\theta}_c$ will be possible for majority of disk and halo events and for a substantial fraction of bulge self-lensing events. For the complete resolution of the lens parameter degeneracy, therefore, SIM observations will be essential.

  • PDF

기계적으로 구현된 장주기 광섬유 격자 Mach-Zehnder 간섭계 (Mechanically induced Mach-Zehnder interferometers based on long-period fiber grating pair)

  • 장현수;조준용;이경식
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.365-368
    • /
    • 2003
  • 본 논문에서는 장주기 광섬유격자쌍을 이용하여 광섬유 Mach-Zehnder 간섭계(MZI)를 기계적인 방법으로 구현해 보았다. 제작한 간섭계의 장주기 광섬유격자쌍의 투과스펙트럼과 fringe spacing의 이론치과 실험치를 비교, 분석해 보았다. 그 결과, fringe spacing의 값은 이론치와 실험치가 비교적 잘 일치하는 것을 알았다.

헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정 (High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers.)

  • 김승우;김민석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.203-206
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state-of-the-art reaches the region of sub-nanometers. We propose a new scheme of phase-measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with electrically generated reference signal. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special from of frequency up-down counting technique is combined with the super-heterodyning. This alloys performing required phase unwrapping simply by using programmable digital gates without 2$\pi$ ambiguities up to the maximum velocity of 2.35 m/s.

  • PDF

레이저 간섭계의 직각 평면거울에 대한 직각도 오차 측정 (Orthogonality Measurement of Square Plane Mirrors for Laser Interferometry)

  • 김태호;김승우
    • 한국정밀공학회지
    • /
    • 제15권12호
    • /
    • pp.169-179
    • /
    • 1998
  • Plane mirror type laser interferometers are popularly being used in many modern ultraprecision machines, as they can perform simultaneous measurements of multiple axis positions with nanometer resolution capabilities. One important issue in this application of laser interferometers is to provide a good level of alignment between the reflecting mirrors and the laser beams so that measurement errors due to undesirable coupling effects can be avoided in multiple axis measurements In this investigation, a thorough metrological analysis is given to develop an suitable mathematical model for a precision x-y stage in which the orthogonality misalignment between the reflecting mirrors significantly affects overall x-y mea-surement results. Then a noble calibration method is suggested in which two-dimensional displacement sensors of moire gratings of concentric circles are used to realize the reversal principle of orthogonality evaluation in situ. Finally, actual experimental results are discussed to verify that the suggested method can effectively calibrate the orthogonality error with an uncertainty of 0.2667 arcsec.

  • PDF

Sagnac 간섭계를 이용한 광섬유 음향 센서의 동적 범위 향상 기법 (A New Technique for Improvement of Dynamic Range in Fiber Optic Acoustic Sensor using Sagnac Interferometers)

  • 남성현
    • 센서학회지
    • /
    • 제9권6호
    • /
    • pp.416-423
    • /
    • 2000
  • Sagnac 간섭계를 이용한 광섬유 음향 센서에서 음향 신호를 간단하면서도 효과적으로 복조할 수 있는 이중위상 천이 신호처리 기법을 제안하고 실험을 통하여 그 특성을 검증하였다. 이 기법을 사용하여 기존의 ${\pi}/2$ 위상 바이어스 복조 방식이 갖는 동적 범위의 이론적 한계를 근본적으로 제거하였다. 이 기법은 고주파의 위상 변조를 하지 않으므로 간단한 전자 회로만으로도 음향 신호의 복조가 가능하다. 또한 디지털 신호처리에 적합하며 다른 간섭계에도 적용이 가능하다.

  • PDF