• 제목/요약/키워드: interference effects

검색결과 786건 처리시간 0.03초

임신기간 중 철 섭취가 모체와 제대 혈청의 미량 무기질 농도에 미치는 영향 (Iron Intake During Pregnancy on Serum Concentrations of Trace Minerals in Mothers and Neonates)

  • 김혜라;임현숙
    • Journal of Nutrition and Health
    • /
    • 제41권3호
    • /
    • pp.242-253
    • /
    • 2008
  • It is a common clinical practice to recommend taking iron supplements for pregnant women during gestation. Although it is required to ensure adequate iron stores during pregnancy, there has been some debate over the interference effects of excessive iron load, because it is possible to compete in the transport in the intestine and placenta and in binding to serum proteins of other trace minerals. In this study, maternal and neonatal serum concentrations of Fe, Zn, Cu, Se, Cr, Mn, and Co were assessed along with maternal Fe intakes. A total of 124 pregnant women and their term neonates participated voluntarily in this research. The women were divided into one of the three groups {high Fe intake (HFI), median Fe intake (MFI), and low Fe intake (LFI)} by their total Fe intakes and one of the two groups (Anemic and Normal) by their Fe nutritional status. All the data were compared among the three groups and between the two groups also. Total Fe intakes of HFI, MFI, and LFI groups were 140.8 ${\pm}$ 76.1, 68.0 ${\pm}$ 11.2, and 30.2 ${\pm}$ 8.6 mg/day, respectively. Those of Anemic and Normal groups were 90.1 ${\pm}$ 74.8 and 86.6 ${\pm}$ 46.8 mg/day, respectively. Maternal Hb concentration and Hct were not significantly different among HFI, MFI, and LFI groups but those were significantly different between Anemic and Normal groups. However, neonatal Hb concentration was not significantly different among HFI, MFI, and LFI groups and between Anemic and Normal groups either. Maternal serum Fe concentrations of the three groups, HFI, MFI, and LFI, were similar but that of Anemic group was significantly lower compared to Normal group. However, there was no significant difference in neonatal serum Fe concentrations among the three groups and between the two groups either. Serum concentrations of the other trace minerals in both mothers and neonates were not significantly different among HFI, MFI, and LFI groups and between Anemic and Normal groups. In addition, in the maternal serum, Fe concentration was positively correlated to Zn and Se concentration, respectively. As for the neonatal serum, Fe concentration showed a positive correlation to Zn, Cu, Mn, Se, and Co concentration, respectively. No trace mineral concentration was found to correlate negatively to Fe concentration in both maternal and neonatal serum, The results in this study indicate that Fe intakes of pregnant women, even if it is considerably above the level of estimated average requirement (EAR), may not affect serum Fe concentration in both mothers and neonates. In addition it might not influence adversely on the availability of other trace minerals including Zn and Cu in both mothers and neonates.

moving-photocarrier-grating 기술을 이용한 디지털 X-선 변환물질 a-Se:As의 수송변수 (Transport parameters in a-Se:As films for digital X-ray conversion material using the moving-photocarrier-grating technique)

  • 박창희;남상희;김재형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.267-272
    • /
    • 2005
  • moving photocarrier grating 기술을 이용하여 디지털 X-선 변환물질 a-Se:As 필름에서 As 첨가효과에 관하여 연구하였다. 이 방법은 시료를 조사하기 위하여 주파수를 변화시킨 2개 레이저 빔의 중첩으로 얻어진 움직이는 간섭패턴을 이용한다. 시료의 수송변수는 시료에서 변조 방향으로 유도되는 grating-속도에 의존하는 전류밀도로부터 얻어진다. As 첨가에 따른 a-Se 필름의 전자와 정공 이동도 그리고 재결합 수명을 구하였다. 전자의 이동도는 결함 상태 때문에 As 첨가에 따라 감소하는 반면, 특히 a-Se 필름에 0.3% As 첨가할 때 정공 이동도와 재결합 수명이 증가하였다. MPG 기술로 얻은 As가 첨가된 a-Se 필름의 수송성질을 a-Se:As로 제작한 X-선 디텍터의 X-선 감도와 비교하였다. 실험결과 0.3% As가 첨가된 a-Se으로 제작한 X-선 디텍터가 가장 우수한 X-선 감도를 나타내었다.

  • PDF

호흡운동을 병행한 몸통 근력운동과 심부 안정화 운동이 배근육 두께와 호흡에 미치는 영향 (Effect of Trunk Strength Exercise and Deep Stabilization Exercise Combined with Breathing Exercise on Abdominal Muscle Thickness and Respiration)

  • 김현수;이건철;추연기
    • 대한통합의학회지
    • /
    • 제8권3호
    • /
    • pp.181-188
    • /
    • 2020
  • Purpose : The purpose of this study is to compare the effects on abdominal muscle thickness and breathing by applying trunk strength exercise and deep stabilization exercise along with breathing exercise, which is the main respiratory muscle during breathing, to present an efficient exercise method with diaphragm breathing. Methods : This study was performed on normal 6 females and 14 males subjects. They were divided into 2 groups which trunk strength exercise and deep stabilization exercise group. The trunk strength exercise group (TSE) attended prone press-up, crunch and pelvic tiling. The deep stabilization exercise group (DSE) attended abdominal drawing, horizontal side-support and bridging exercise. Breathing exercise was performed for each set break time for 1 minute. Results : First, in the comparison of the change in the thickness of the abdominal muscle between the trunk strength training group and the deep stabilization group before and after exercise, there was a statistically significant difference in the comparison of transverse abdominis (TrA), rectus femoris (RF), external oblique (EO), internal oblique (IO) (p<.05). However, there was no significant difference in any comparison between groups (p>.05). Second, in the comparison of changes in respiratory function between the trunk strength exercise group and the deep stabilization exercise group before and after exercise, there were statistically significant differences in the exerted forced vital capacity (FVC), forced expiratory volume at one second (FEV1), peak expiratory flow (PEF) in the comparison before and after the experiment (p<.05). However, there was no significant difference in any comparison between groups (p>.05). Conclusion : As a result of this study, it can be said that both trunk strength exercises and deep stabilization exercises along with diaphragm breathing are exercises that strengthen deep and superficial muscles, and have a positive effect on breathing function as well as muscle strength. However, it is not known which exercise was more effective, and because it was combined with breathing exercise, the interference effect appeared.

흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구 (A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom)

  • 황혜성;김누리;정윤지;구은회;김기정
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

스마트라이프가 정치.사회.문화.경제에 미치는 영향 (Effect of Smart Life on Politics, Society, Culture, and Economy)

  • 김만기
    • 디지털융복합연구
    • /
    • 제9권6호
    • /
    • pp.91-102
    • /
    • 2011
  • 스마트워크는 동시대 우리생활의 삶에 깊숙이 내재되어 있다. 이를 스마트라이프라고 할 수 있다. 스마트라이프가 가져온 커뮤니케이션의 확장은 정치적으로 정치인, 정치후보자, 정당정책 등에 활용되고 있다. 주로 인지도 향상, 인맥관리, 정책지지 등이다. 사회적으로는 이슈 확산, 시민운동 등을 전개하고 있다. 스마트라이트의 영향이 큰 분야는 문화적 확산이다. K-POP 의 경우는 빠르게 시공간을 초월하여 확산됨과 동시에 참여하고 공유하면서 곧 경제적 부가가치를 높이고 있다. 하지만 스마트라이프에 의한 삶의 질을 향상시켜 주는 등 편리한 장점도 많지만 스마트라이프를 받아들이는 세대 간 정도의 차이와 사용자에 따라 불편함도 가져오고 있다. 오직 기기에 의존하기 때문에 그로 인한 인간의 사고력 부재, 사생활 노출, 보안취약, 인터넷이나 SNS에 접속하지 않으면 불안해하는 정보중독자 증가, 업무차질 등 부작용을 발생시키고 있다. 그러나 이런 불편함은 곧 익숙하게 되어 편리함으로 바뀌게 된다. 이처럼 스마트라이프는 정치 경제 사회 문화영역에서 많은 영향을 끼치고 있다. 스마트라이프의 근로환경은 '이지 이코노미(easy economy)'로 신나게 똑똑하게 일하고 그 결과를 중시하면서 높은 성과를 창출할 수 있는 새로운 패러다임이다.

캐너비노이드 수용체 CB2의 신호전달작용에 미치는 RGS3의 억제적 효과 (RGS3 Suppresses cAMP Response Element (CRE) Activity Mediated by CB2 Cannabinoid Receptor in HEK293 Cells)

  • 김성대;이휘민;메하리 엔델;조재열;박화진;오재욱;이만휘
    • 생명과학회지
    • /
    • 제19권11호
    • /
    • pp.1506-1513
    • /
    • 2009
  • RGS단백질은 G 단백질 신호전달작용에 있어서 신호를 억제하는 조절단백질로서 G 단백질 매개수용체(GPCR)의 활성을 억제하는 것으로 알려졌다. 그렇지만 캐너비노이드 수용체 CB2의 활성에 있어서 RGS 단백질의 조절효과에 관해서는 지금까지 알려져 있지 않다. 그러므로 본 연구에서 우리는 RGS2, 3, 4, 5와 캐너비노이드 수용체 CB2 cDNA를 동시에 HEK293 세포주에 발현시킨 후 각 RGS 단백질의 효과를 조사하였다. CB2 단백질을 발현하는 HEK293 세포주(CB2-HEK293)에서 CB2 효현제인 WIN55,212-2는 폴스콜린으로 유도된 cAMP response element (CRE) 활성을 억제하였다. 이러한 WIN55,212-2의 CRE 억제 활성은 RGS3에 의하여 차단되었지만 RGS2, 4, 및 RGS5에서는 관찰되지 않았다. 뿐만 아니라 RGS3 small interference RNA (siRNA)를 사용하여 내인성 RGS3 단백질의 발현을 저하시키면 WIN55,212-2에 의한 폴스콜린 유도 CRE 억제활성은 더욱 증강되었다. 이상의 결과는 캐너비노이드 수용체 CB2 신호전달작용에 있어서 RGS 단백질의 기능적 역할과 특히 내인성 RGS3의 캐너비노이드 수용체 CB2에 대한 선택적 작용을 나타낸다.

OFDM 시스템에서 시간 및 주파수 영역 클리핑의 Total Degradation 성능평가 (Total Degradation Performance Evaluation of the Time- and Frequency-Domain Clipping in OFDM Systems)

  • 한창식;서만중;임성빈
    • 대한전자공학회논문지TC
    • /
    • 제44권7호통권361호
    • /
    • pp.17-22
    • /
    • 2007
  • OFDM (Orthogonal Frequency Division Multiplexing)시스템은 다수 반송파 전송의 특수한 형태로 볼 수 있으며 하나의 데이터열이 보다 낮은 데이터 전송률을 갖는 부반송파를 통해 전송된다. OFDM을 사용하는 중요한 이유 중 하나는 OFDM을 사용하면 주파수 선택적 페이딩이나 협대역 간섭에 대한 강건함이 증가하기 때문이다. 하지만, 시간 영역 OFDM 신호는 독립적으로 변조된 많은 부반송파들로 구성되므로 이들이 동위상으로 더해질 때 신호의 진폭이 증가하여 PAPR (Peak-to-Average Power Ratio)이 증가된다. 본 논문에서는 수신단의 구조에 변화를 주지 않으며 또한 추가적인 정보의 전송이 필요 없이 기존 수신기를 그대로 사용할 수 있는 PAPR 감소기법의 성능을 평가하였다. 이 방법은 에러 벡터 크기 (Error Vector Magnitude; EVM) 내에서 시간 영역과 주파수 영역 신호에 대하여 클리핑을 사용한 것으로 기존의 최적화 방법과 비교하여 계산량의 복잡도가 낮다. 이 기법을 비선형 증폭기를 사용하는 OFDM 시스템에서 평가하였다. 모의실험 결과, 시간 및 주파수 영역 클리핑 기반의 PAPR 감소기법은 TD (Total Degradation)관점에서 전력효율이 향상되며 증폭기의 비선형 왜곡의 영향을 줄이는 효과가 있음을 확인할 수 있었다.

4,5-Dihydroxy-1,3-Benzenedisulfonic Acid를 이용한 Fe(Ⅲ)의 분광형광법 정량 (Spectrofluorimetric Determination of Fe(Ⅲ) with 4,5-Dihydroxy-1,3-Benzenedisulfonic Acid)

  • 김혜선;최희선
    • 대한화학회지
    • /
    • 제43권4호
    • /
    • pp.423-429
    • /
    • 1999
  • 형광체로서 4,5-dihydroxy-1,3-benzenedisulfonic acid(Tiron)를 이용하여 수용액속의 Fe(III)를 정량할 수 있는 분광형광법에 대해 연구하였다. 물에 잘 용해되는 Tiron은 좋은 형광시약이지만, Fe(III)와 착물을 이루면 소광 효과로 인해 형광의 세기가 Fe(III)의 농도에 비례하여 감소하였다. pH 4.5에서 Fe(III)에 의해 소광 효과를 보여주는 Tiron의 들뜸 및 형광 파장은 각각 312 nm와 341 nm이었다. 감도는 Tiron의 농도가 $1.0{\times}10^{-2}M$일 때 가장 좋았다. 소광효과를 증가시키기 위하여 Fe(III)-Tiron 착물 용액을 80$^{\circ}C$에서 90분 동안 가열하였다. Fe(III)의 경우 가장 방해하는 이온은 Cu(II) 이었는데, 이는 pH를 조절하거나 EDTA를 넣어주므로서 방해효과를 없앨 수 있었다. Fe(III)의 직선 농도범위는 $5.0{\times}10^{-7}M$ 에서 $6.0{\times}10^{-5}M$까지 이었다. 이 제시된 방법의 검출한계는 $2.8{\times}10^{-6}M$이었고, 합성시료에서 Fe(III)의 회수는 거의 정량적으로 이루어졌다. 실험결과를 종합하여 보면, 이 제시된 방법을 이용하면 실제 시료에 들어있는 Fe(III)을 정량할 수 있을 것이다.

  • PDF

부모의 양육태도와 청소년의 주관적 계층감이 게임중독에 미치는 영향에 관한 연구 (Effects of Parenting Attitude and Youth's Subjective Class Identification on Game Addiction)

  • 장예빛;이혜림;김민철;유승호;정의준
    • 한국게임학회 논문지
    • /
    • 제13권6호
    • /
    • pp.53-64
    • /
    • 2013
  • 본 논문에서는 부모의 자녀 양육태도와 청소년이 가진 주관적 계층감의 차이에 따라 청소년의 중독적 게임이용이 어떠한 차이를 나타내는지를 살펴보았다. 16세에서 24세 사이의 총 177명의 게임이용연령층을 대상으로 한 온라인 서베이 분석 결과, 전체 집단의 경우 부모의 양육태도 중 과잉기대요인과 청소년 개인이 가진 높은 자기통제 수준이 게임중독이 낮은 것으로 나타났다. 주관적 계층감에 따라 전체 집단을 나누어 다시 살펴본 결과, 주관적 계층감이 낮은 집단(주관적 빈곤감이 높은 그룹)에서는 부모의 양육태도 중 과잉기대 요인이 높고, 자기통제 수준이 높을수록 게임중독이 낮아지는 것으로 밝혀졌다. 반면, 주관적 계층감이 높은 집단(주관적 빈곤감이 낮은 그룹)에서는 부모의 양육태도 중 간섭 요인만이 게임중독을 낮추는 유일한 요인으로 드러났다. 이는 부모의 양육태도 중 특정 요인과 청소년이 가진 주관적 계층감이 게임을 비롯한 다양한 미디어의 중독적 사용과 중요한 관련을 가지고 있음을 시사하는 결과라 할 수 있다.

Electrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

  • Giribabu, Krishnan;Jang, Sung-Chan;Haldorai, Yuvaraj;Rethinasabapathy, Muruganantham;Oh, Seo Yeong;Rengaraj, Arunkumar;Han, Young-Kyu;Cho, Wan-Seob;Roh, Changhyun;Huh, Yun Suk
    • Carbon letters
    • /
    • 제23권
    • /
    • pp.38-47
    • /
    • 2017
  • In this study, magnetite ($Fe_3O_4$) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like $Fe_3O_4$ nanoparticles with a mean size of < 80 nm were electrodeposited on a glassy carbon electrode (GCE). The $Fe_3O_4/GCE$ was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the $Fe_3O_4/GCE$ was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the $Fe_3O_4/GCE$. The electrocatalytic ability of $Fe_3O_4$ was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the $Fe_3O_4/GCE$ exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of $0.09-47{\mu}M$ with a correlation coefficient of 0.9919 and a limit of detection of $0.09{\mu}M$ (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.