• 제목/요약/키워드: interfacial characteristic

검색결과 74건 처리시간 0.027초

도포된 오일의 변화에 따른 Epoxy/EPDM 계면의 교류 절연파괴 특성에 관한 연구 (A Study on the AC Interfacial Breakdown Properties of the Interface between Epoxy/EPDM with Variation of the Spread Oil)

  • 배덕권;정일형;오재한;박우현;이기식;김충혁;이준웅
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.445-450
    • /
    • 2000
  • Many successful developments and microscopic studies have been made on the high quality insulating materials. However, a little attention have given to the macroscopic interface in HV(High Voltage) insulating systems. In this study, AC interfacial breakdown strength and V-t characteristic of the interface between Epoxy/EPDM(ethylene propylene diene terpolymer) are investigated. Electrode system is designed to reduce the charges from electrodes and to have the tangential potentials along the interface between Epoxy/EPDM by FEM(finite elements method). The AC breakdown strength is observed when HV is given to the interface. It is shown that AC interfacial breakdown strength is improved by increasing interfacial pressure and oiling. In particular, it was saturated at certain interfacial pressure level. V-t characteristic is able to extend to the life time of the interface between Epoxy/EPDM. Oiling also plays a good roll in prolongation of the life time.

  • PDF

Two new relationships for slip velocity and characteristic velocity in a non-center rotating column

  • Torkaman, Rezvan;Heydari, Mehran;Cheshmeh, Javad Najafi;Heydari, Ali;Asadollahzadeh, Mehdi
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2809-2818
    • /
    • 2022
  • In this investigation work, liquid-liquid extraction (L.L.E) through three distinctive frameworks have been examined for assurance of slip velocity (S.V), and characteristic velocity (C.V) in a non-center rotating column (N.C.R.C) with a wide extend of factors. Three double frameworks with distinctive interfacial tension comprising of toluene-water (high interfacial tension), n-butyl acetate-water (medium interfacial tension), and n-butanol-water (low interfacial tension) were investigated for tests. Two common relationships for the expectation of S.V and C.V, including phase stream rates, rotor speed, column geometry additionally physical properties, are displayed. The recommended relationships were compared with test information gotten from the writing and the display examination. Findings of this study, the present proposed correlations are more accurate than those previously reported.

한국형틸팅열차 틸팅기구장치 부하특성 평가 연구(II) - 대차/차체 인터페이스 조정에 의한 정적부하 영향분석 (Study for Loading Characteristic of Tilting Mechanism on Korea Tilting Train (II) - Adjustmemt for Interface of carbody and Bogie)

  • 고태환;이왕상;이범상
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.951-956
    • /
    • 2011
  • As the evaluation of loading characteristic on tilting mechanism is the most important one of the function test of tilting mechanism, the changing characteristic of load must be investigated on tilting of carbody for both the static and running condition of train. In this study, we reduced the load of tilting mechanism by adjusting the interface of carbody and bogie such as the weight balance, level of underframe, height of leveling valve, height of axle box and center position of tilting actuator with the characteristic curve of load for optimal condition of the tilting mechanism obtained in the previous study. Furthermore, the factor and effect of the interfacial structures respecting the load of tilting mechanism was evaluated by analyzing the changing characteristic of load obtained in the process of adjustment of interfaces. From these data, we will propose the maintenance standards for interfacial structures and tilting mechanism in order to minimize the load of tilting mechanism by analyzing in detail the characteristic of load for the main factors of the interfacial structure effecting on the load of tilting mechanism.

  • PDF

슬러리법에 의한 탄소섬유보강 시멘트복합체의 제조에서 보강섬유와 계면결착제와의 상관특성 (Characteristics Correlations Between Fiber-Reinforced and Interfacial Adhesion in Carbon fiber reinforced Cement composite Prepared by Slurry Method.)

  • 최응규
    • 한국건축시공학회지
    • /
    • 제2권3호
    • /
    • pp.131-138
    • /
    • 2002
  • The objective of the study is to examine the characteristic correlations between reinforcing carbon fiber and interfacial adhesion agent since the interfacial adhesion strength between reinforcing carbon fiber and matrices is believed to be an essential element influencing the physical properties in carbon fiber reinforced cement composite using slurry method. The integrity of interfacial adhesion between reinforcing fiber and cement not only affects the quality of fiber reinforced cement composite but also influences to a large degree the physical properties of the cement composite when producing carbon fiber reinforced cement composite using slurry method. Having analyzed the physical properties 1.e., water content, tensile strength, flexural strength and flexural toughness of carbon fiber reinforced cement composite specimens, C-PAM(cation polyacrylamide) was determined to be an optimum interfacial adhesion agent. The study has also demonstrated that interfacial adhesion strength varies largely on the content and type of the reinforcing fiber. Judging from magnified view of the tensile shear cross-section using VMS(video microscope system), interfacial adhesion strength between reinforcing fiber and matrices is affected by the type of interfacial adhesion agent. According to the result of the experiments, C-PAM was determined to be an ideal interfacial adhesion agent when using carbon fiber in producing carbon fiber reinforced cement composite with the optimum content of carbon fiber being established.

에폭시/고무 거시계면에서 장시간 절연파괴전압에 대한 연구 (Study on the Long Time Breakdown Voltage in the Macro Interface between Epoxy and Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.1003-1008
    • /
    • 2002
  • In this paper, the estimation of lifetime with the various conditions of the interface between toughened epoxy and rubber which are consisting materials of underground power delivery system has been studied. After the measurement of the short time AC interfacial breakdown strength on macro interfaces at room temperature, the breakdown time at several voltages were measured under the constant voltages lower than the short time breakdown voltage. The long time breakdown voltage was calculated by using Inverse Power Law. Two types of interfaces was studied. One was the interface between toughened epoxy and EPDM(Ethylene Prorylene Diene Terpolymer). The other was the interface between toughened epoxy and silicon rubber. Interfacial pressure and roughness of interfaces was determined through the characteristic of short time AC interfacial breakdown strength. Oil condition was no oiled, low viscosity oiled and high viscosity oiled. High viscosity oiled interface between Toughened epoxy and silicon rubber had the best lifetime exponent, 20.69. and the breakdown voltage of this interface after 30 years was evaluated 19.27㎸.

DEVELOPMENT OF INTERFACIAL AREA TRANSPORT EQUATION

  • ISHII MAMORU;KIM SEUNGJIN;KELLY JOSEPH
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.525-536
    • /
    • 2005
  • The interfacial area transport equation dynamically models the changes in interfacial structures along the flow field by mechanistically modeling the creation and destruction of dispersed phase. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport mechanism for various sizes of bubbles, the transport equation is formulated for two characteristic groups of bubbles. The group 1 equation describes the transport of small-dispersed bubbles, whereas the group 2 equation describes the transport of large cap, slug or chum-turbulent bubbles. To evaluate the feasibility and reliability of interfacial area transport equation available at present, it is benchmarked by an extensive database established in various two-phase flow configurations spanning from bubbly to chum-turbulent flow regimes. The geometrical effect in interfacial area transport is examined by the data acquired in vertical fir-water two-phase flow through round pipes of various sizes and a confined flow duct, and by those acquired In vertical co-current downward air-water two-phase flow through round pipes of two different sizes.

수송기기 유압 실린더 블록 재료의 Fe-Cu 계면반응 특성 (A Characteristic of Fe-Cu Interfacial Reaction in the Hydraulic Cylinder Block for Vehicle Parts)

  • 김해지;김남경
    • 한국기계가공학회지
    • /
    • 제3권1호
    • /
    • pp.90-94
    • /
    • 2004
  • Generally, a hydraulic cylinder block which is one of a vehicle parts that plays Important role in excavator power transmission, has copper alloy separation phenomenon by sliding motion between metals in high pressure condition. In this paper, to solve this problem, the interfacial reaction layer of Fe-Cu With SCM440 and copper alloy is studied through the melting method. As the result of this study, it is found that the interfacial reaction layer of $1{\mu}m$ created in the interface of Fe-Cu which has very strong physical bonding. It has been also confirmed that the melting method can improve life of the hydraulic cylinder block.

  • PDF

Characteristics of the plume formed by the buoyant discharges from the river

  • Kim, Ki-Cheol;Kim, Sung-Bo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권8호
    • /
    • pp.981-994
    • /
    • 2014
  • Density currents formed by buoyancy discharges from rivers are numerically studied using non-dimensional two layer model including Coriolis acceleration, bottom stress, interfacial friction. Some typical numbers such as Froude number, densimetric Froude number and Kelvin number are obtained and some characteristic scales are defined as a result of non-dimensionalization of the governing equations. Besides the Coriolis effect, the configurations of bottom topography, bottom friction coefficient and interfacial friction are found to significantly affect the propagation of the warm water plume. Frontal position can fastly propagate in the case of large density difference between the two layers and small interfacial friction. Left side boundary current is easily formed under the small interfacial friction. With large Kelvin number, both right and left side boundary currents are formed. Wave-like disturbances and eddies are easily formed under the high Froude number.

Mechanical behaviour between adjacent cracks in CFRP plate reinforced RC slabs

  • Yuan, Xin;Bai, Hongyu;Sun, Chen;Li, Qinqing;Song, Yanfeng
    • Structural Engineering and Mechanics
    • /
    • 제84권3호
    • /
    • pp.375-391
    • /
    • 2022
  • This paper discussed and analyzed the interfacial stress distribution characteristic of adjacent cracks in Carbon Fiber Reinforced Polymer (CFRP) plate strengthened concrete slabs. One un-strengthened concrete test beam and four CFRP plate-strengthened concrete test beams were designed to carry out four-point flexural tests. The test data shows that the interfacial shear stress between the interface of CFRP plate and concrete can effectively reduce the crack shrinkage of the tensile concrete and reduces the width of crack. The maximum main crack flexural height in pure bending section of the strengthened specimen is smaller than that of the un-strengthened specimen, the CFRP plate improves the rigidity of specimens without brittle failure. The average ultimate bearing capacity of the CFRP-strengthened specimens was increased by 64.3% compared to that without CFRP-strengthen. This indicites that CFRP enhancement measures can effectively improve the ultimate bearing capacity and delay the occurrence of debonding damage. Based on the derivation of mechanical analysis model, the calculation formula of interfacial shear stress between adjacent cracks is proposed. The distributions characteristics of interfacial shear stress between certain crack widths were given. In the intermediate cracking region of pure bending sections, the length of the interfacial softening near the mid-span cracking position gradually increases as the load increases. The CFRP-concrete interface debonding capacity with the larger adjacent crack spacing is lower than that with the smaller adjacent crack spacing. The theoretical calculation results of interfacial bonding shear stress between adjacent cracks have good agreement with the experimental results. The interfacial debonding failure between adjacent cracks in the intermediate cracking region was mainly caused by the root of the main crack. The larger the spacing between adjacent cracks exists, the easier the interfacial debonding failure occurs.

콘크리트내 표면매입 보강된 FRP 판과 콘크리트 사이의 착-미끄러짐 관계 해석 (Analysis on the Interfacial Bond-Slip Relationship between ear Surface-Mounted FRP Plate and Concrete)

  • 서수연
    • 콘크리트학회논문집
    • /
    • 제26권1호
    • /
    • pp.79-86
    • /
    • 2014
  • 이 연구는 표면매입 보강된 FRP 판과 콘크리트사이의 응력전달기구를 이론적으로 연구한 것으로서 이선형 부착모델을 이용하여 부착거동을 묘사하고 이를 실험 결과와 비교하여 신뢰성있는 해석방법을 제시하였다. 연구로부터, 표면매입된 FRP 판과 콘크리트사이의 계면특성을 고려한 미분방정식에 이선형 부착-미끄러짐 관계곡선을 사용하여 해석할 경우, 모델의 임계값인 최대전단강도와 미끄러짐 변위, 그리고 박락에 의한 연화거동이 시작될 때의 변위값 선정과정이 제시되었다. 또한 제안된 모델을 사용하여 부착길이가 다르게 보강된 표면매입 FRP 판의 미끄러짐 거동을 해석한 결과 실제 거동을 매우 근사하게 묘사할 수 있는 것으로 나타났다.