• Title/Summary/Keyword: interface parameters

Search Result 974, Processing Time 0.028 seconds

Steady-state response and free vibration of an embedded imperfect smart functionally graded hollow cylinder filled with compressible fluid

  • Bian, Z.G.;Chen, W.Q.;Zhao, J.
    • Structural Engineering and Mechanics
    • /
    • v.34 no.4
    • /
    • pp.449-474
    • /
    • 2010
  • A smart hollow cylinder consisting of a host functionally graded elastic core layer and two surface homogeneous piezoelectric layers is presented in this paper. The bonding between the layers can be perfect or imperfect, depending on the parameters taken in the general linear spring-layer interface model. The effect of such weak interfaces on free vibration and steady-state response is then investigated. Piezoelectric layers at inner and outer surfaces are polarized axially or radially and act as a sensor and an actuator respectively. For a simply supported condition, the state equations with non-constant coefficients are obtained directly from the formulations of elasticity/piezoelasticity. An approximate laminated model is then introduced for the sake of solving the state equations conveniently. It is further assumed that the hollow cylinder is embedded in an elastic medium and is simultaneously filled with compressible fluid. The interaction between the structure and its surrounding media is taken into account. Numerical examples are finally given with discussions on the effect of some related parameters.

Modelling of bonded and unbonded post-tensioned concrete flat slabs under flexural and thermal loading

  • Mohammed, Abbas H.;Taysi, Nildem
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.595-606
    • /
    • 2017
  • During their life span, post-tensioned concrete structures may be exposed to thermal loads. Therefore, there has been a growing interest in research on the advanced analysis and design of post-tensioned concrete slabs subjected to thermal loads. This paper investigates the structural behaviour of post-tensioned one-way spanning concrete slabs. A nonlinear finite element model for the analysis of post- tensioned unbonded and bonded concrete slabs at elevated temperatures was developed. The interface between the tendon and surrounding concrete was also modelled, allowing the tendon to retain its profile shape during the deformation of the slab. The load-deflection behaviour, load-force behaviour in the tendon, and the failure modes are presented. The numerical analysis was conducted by the finite element ANSYS software and was carried out on two different one-way concrete slabs chosen from literature. A parametric study was conducted to investigate the effect of several selected parameters on the overall behavior of post-tensioned one-way concrete slab. These parameters include the effect of tendon bonding, the effect of thermal loading and the effect of tendon profile. Comparison between uniform thermal loading and nonuniform thermal loading showed that restrained post tensioned slab with bottom surface hotter has smaller failure load capacity.

Effect of Slab-base Friction on Response of JCP Slab with Different Material and Geometric Properties

  • Sun, Ren-Juan;Lim, Jin-Sun;Jeong, Jin-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.99-110
    • /
    • 2007
  • A single slab concrete pavement has been modeled and analyzed by ABAQUS program. The stress and displacement of the JCP slab under traffic load with frictionless contact interaction between slab and base calculated by ABAQUS program have been compared with the results obtained by KENSLABS program. The results of the stresses of the two modeling show similar tendency and the difference of the two modeling is very small however the results of the displacement of the two modeling show some dissimilarity. In order to analyze the effects of material and geometric properties on the responses of slab, some varying parameters were chosen as input for the modeling. The changing parameters include the thickness and elastic modulus of the concrete slab, the thickness and elastic modulus of base and the elastic modulus of the subgrade. The contact interaction between the slab and base layer had been also studied and different friction coefficient 0, 2.5, 6.6, 7.5, 8.9 had been used to simulate the different friction interface condition. The results of the analysis showed that the responses of the concrete slab vary with the material and geometric properties of the pavement structure and the slab-base friction condition.

Implementation of an Emulator for the Integrated Image Reconstruction according to Distance (거리에 따른 집적 영상 복원을 지원하는 에뮬레이터의 구현)

  • Jang, Ha Eun;Lee, Eun Ji;Lee, Yeon Ju;Lim, Soon-Bum
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.3
    • /
    • pp.548-556
    • /
    • 2016
  • Integral imaging is an auto-stereoscopic display method that can produce 3D image of a finite viewing window through an array of micro elemental lenses. Integral imaging requires the pickup part of each elemental images acquisition and display part of reconstruction of the images. The successful reconstructed image depends on various parameters such as distance between lens arrays and display device, focal length of lenses, and a number of the array. In this paper, we present reconstruction emulator for display of Integral imaging in order to adjust parameters for 3D contents reconstruction and to observe the result from different configuration. Especially, we provide the user interface for the emulator to control the distance easily. We have confirmed through various experiments that the emulator adjusted the distance and could check error in the process of creating elemental images.

ANALYSIS OF THE OCEAN' AND ATMOSPHERE ROLES IN THEIR HEAT INTERACTION WITH USE OF SATELLITE AND VESSEL

  • Grankov, Alexander Georgievich;Mil'shin, Alexander Alexeevich;Krapivin, Vladimir Fedorovich;Golovachev, Sergey Petrovich
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.1001-1002
    • /
    • 2006
  • Special problem emphasized by specialists in the field of analyzing the heat interchanges in the system ocean-atmosphere (SOA) is a necessity of determination of the near-surface atmospheric temperature, which can be only indirectly connected with characteristics of the SOA natural microwave radiation measured from satellites. That is why, the following dilemma is not obvious, but interesting and promised: what is better - to use the satellite methods for retrieving the partial parameters of the SOA or for analysis its state as a whole. To our opinion, this task is similar to the idea recognized by specialists engaged in the heat infrared region (8-12 mcm) of electromagnetic spectrum and its applications, where an intensity of natural infrared radiation (effective radiation) is used as the inherent property (the attribute) of the SOA heat balance. Here we studied important aspects of this problem: a) what medium initiates a heat transfer in the SOA and disturbs its heat balance - the ocean or the atmosphere b) what SOA parameters directly influence on its natural microwave radiation intensity (brightness temperature) measured from satellites? We relate these processes mainly to the synoptic range of time scales enriched by various events in the SOA interface such as the mid-latitude and tropical cyclones.

  • PDF

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF

Design and Fabrication of Low Power Sensor Network Platform for Ubiquitous Health Care

  • Lee, Young-Dong;Jeong, Do-Un;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1826-1829
    • /
    • 2005
  • Recent advancement in wireless communications and electronics has enabled the development of low power sensor network. Wireless sensor network are often used in remote monitoring control applications, health care, security and environmental monitoring. Wireless sensor networks are an emerging technology consisting of small, low-power, and low-cost devices that integrate limited computation, sensing, and radio communication capabilities. Sensor network platform for health care has been designed, fabricated and tested. This system consists of an embedded micro-controller, Radio Frequency (RF) transceiver, power management, I/O expansion, and serial communication (RS-232). The hardware platform uses Atmel ATmega128L 8-bit ultra low power RISC processor with 128KB flash memory as the program memory and 4KB SRAM as the data memory. The radio transceiver (Chipcon CC1000) operates in the ISM band at 433MHz or 916MHz with a maximum data rate of 76.8kbps. Also, the indoor radio range is approximately 20-30m. When many sensors have to communicate with the controller, standard communication interfaces such as Serial Peripheral Interface (SPI) or Integrated Circuit ($I^{2}C$) allow sharing a single communication bus. With its low power, the smallest and low cost design, the wireless sensor network system and wireless sensing electronics to collect health-related information of human vitality and main physiological parameters (ECG, Temperature, Perspiration, Blood Pressure and some more vitality parameters, etc.)

  • PDF

Development of Method for Deciding Automatically Parameters of Water Quality Simulation Models (수질모형의 매개변수 자동보정 프로그램 개발에 관한 연구)

  • Song, Kwang-Duck;Paik, Do Hyeon;Lee, Yong Woon
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 2006
  • Water quality simulation models include the difference between the measured and estimated values as an inevitable consequence because they represent the complicated natural phenomena as simplified mathematical equations. The major reason of the difference occurrence is due to the use of the imprecise values of the model parameters, but the parameter values are currently determined by the try and error method directly performed by humans. However, the use of this method requires many time and endeavor of humans, and generally does not obtain the most suitable parameter values. A method for deciding model parameter values is, therefore, developed in this study. The method minimizes the difference between the measured and estimated values and also distributes uniformly the measured values on the upper and lower sides of the line representing the estimated values. A user interface based on this method is also developed by using the Visual Basic 6.0 of Microsoft, and it can be operated in the environment of Windows 98/2000. In this study, the method for deciding model parameter values is applied for estimating the water quality of the stream Ko-heung. The results of the application show that the method, including its computer program, can effectively obtain the most suitable parameter values and also save many working time in comparison with the existing method directly performed by humans.

Crystal growth from melt in combined heater-magnet modules

  • Rudolph, P.;Czupalla, M.;Dropka, N.;Frank-Rotsch, Ch.;KieBling, F.M.;Klein, O.;Lux, B.;Miller, W.;Rehse, U.;Root, O.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.5
    • /
    • pp.215-222
    • /
    • 2009
  • Many concepts of external magnetic field applications in crystal growth processes have been developed to control melt convection, impurity content and growing interface shape. Especially, travelling magnetic fields (TMF) are of certain advantages. However, strong shielding effects appear when the TMF coils are placed outside the growth vessel. To achieve a solution of industrial relevance within the framework of the $KRISTMAG^{(R)}$ project inner heater-magnet modules(HMM) for simultaneous generation of temperature and magnetic field have been developed. At the same time, as the temperature is controlled as usual, e.g. by DC, the characteristics of the magnetic field can be adjusted via frequency, phase shift of the alternating current (AC) and by changing the amplitude via the AC/DC ratio. Global modelling and dummy measurements were used to optimize and validate the HMM configuration and process parameters. GaAs and Ge single crystals with improved parameters were grown in HMM-equipped industrial liquid encapsulated Czochralski (LEC) puller and commercial vertical gradient freeze (VGF) furnace, respectively. The vapour pressure controlled Czochralski (VCz) variant without boric oxide encapsulation was used to study the movement of floating particles by the TMF-driven vortices.

PLUG-IN MODULES ON PLUTO FOR IDENTIFYING INFLAMMATORY NODULES FROM LUNG NODULES IN CHEST X-RAY CT IMAGES

  • Hirano, Yasushi;Seki, Nobuhiko;Eguchi, Kenji
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.794-798
    • /
    • 2009
  • We introduce an implementation of plug-ins on PLUTO. These plug-ins discriminate inflammatory nodules from other types of nodules in chest X-ray CT images. The PLUTO is a common platform for computer-aided diagnosis systems on Microsoft Windows series and it is easy to add new functions as plug-ins. We coded two plug-ins. One of the them calculates features based on medical knowledge. The other plug-in calculates parameters to classify the type of nodules, and it also classifies nodules into inflammatory nodules and others using SVM. These plug-ins are coded using MIST library which is produced at Nagoya University, Japan. In our previous study, the MIST library was parallelized, so that we can utilize a number of CPUs to calculate features and SVM learning/classifying depending on the amount of computation. Using these plug-ins, it became easy to extract features to discriminate inflammatory nodules from other types of nodules and to change parameters for feature extraction and SVM learning/classifying with GUI interface. The accuracy of the classifying result is 100% with 78 solid nodules which contains 43 inflammatory nodules and 35 other type of nodules.

  • PDF