• 제목/요약/키워드: interface integrity evaluation

검색결과 16건 처리시간 0.03초

자기애자 캡의 금구-시멘트 계면 건전성 평가를 위한 초음파법 활용에 대한 연구 (A Study on the Application of Ultrasonic Testing for The Interface Integrity Evaluation between Iron and Cement of Porcelain Insulator Cap)

  • 윤영근;최인혁;손주암;오태근
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.58-65
    • /
    • 2018
  • The life span of the porcelain insulator was made to be 30 years, but currently many of the 154kV NGK porcelain insulators using in Korea are found to have passed the production life. Accidents caused by aged mechanical breakdown can lead to disruption of power supply in some areas, large economic losses, and casualties. Therefore, ultrasonic method, which is one of the non - destructive test methods, is applied as a method for evaluating the integrity of porcelain insulators. In this study, the experiment on the interface of cap was conducted and the difference between the energy difference and the attenuation coefficient of the reflected wave was derived according to the interface state of the steel - cement. The results of this study are expected to be used as the basic data of the ultrasonic testing to evaluate the interface condition of the porcelain insulator cap.

압자압입시험에 의한 이종재료 접합층의 계면인성 평가 (Evaluation of Apparent Interface Toughness of Composites Layers by Indentation Test)

  • 송준희;김학근;임재규
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2089-2095
    • /
    • 2002
  • Ceramic/metal composites have many attractive properties and great potential fur applications. Interfacial fracture properties of different layered composites are important in material integrity. Therefore, evaluation of fracture toughness at interface is required in essence. In this study, the mechanical characteristics for interface of ceramic/metal composites were investigated by indentation test of micro-hardness method. Apparent interfacial toughness of TBC system could be determined with a relation between the applied load and the length of the crack formed at the interface by indentation test.

TAA신호를 이용한 하드디스크의 헤드/디스크 인터페이스 분석 (Evaluation of Head/Disk interface using TAA Signal)

  • 박용식;이재모;김대은
    • 한국정밀공학회지
    • /
    • 제18권3호
    • /
    • pp.107-114
    • /
    • 2001
  • The durability of head/disk interface is an important issue for hard disk drives. Currently, there are several means of assessing the performance and integrity of the head/disk interface. In this work Track Average Amplitude(TAA) signal was used to analyzed the head/disk interface with respect to variations in disk velocity, slider pre-load and preformed scratch on the disk. Particularly, TAA variation due to disk defect in the form of a scratch was investigated.

  • PDF

천연가스 공급배관의 사용적합성 통합프로그램 (Integrated Fitness-for-service Program for Natural Gas Transmission Pipeline)

  • 김우식;김영표;김철만;백종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.269-274
    • /
    • 2008
  • For fitness-for-service analyses of underground natural gas pipelines, engineering assessment methods against possible defects need to be developed. The assessment methods for high pressure pipeline of KOGAS, was developed using the full size pipe burst tests and the finite element analysis. It included the defect assessment methods for a single and multi-corrosion, corrosion in girth welding part, corrosion in seam welding part, the mechanical damage defects as dent and gouge, crack and large plastic deformation of API 5L X65 pipe. In addition, we developed method to assess pipeline integrity by internal and external load to buried pipeline. Evaluation results were compared with other methods currently being applied to the gas pipeline. The program of Windows environment is made for easily using assessment methods. It provides a consistent user interface, so non-professional technician can easily and friendly use the FFS program from company intranet. Several evaluation programs is easily installed using one installer. Each program constitutes a common input interface and the output configuration program, and evaluation result store and can be recalled at any time. The FFS program based on independent evaluation method is used to evaluate the integrity and safety of KOGAS pipeline, and greatly contribute to safe and efficient operation of pipeline. This paper presents experimental, analytical and numerical investigations to develop the FFS methods for KOGAS pipeline, used as high pressure natural gas transmission pipeline within KOREA. Also, it includes the description of the integrated program for FFS methods.

  • PDF

폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성 (Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing)

  • 조한구;유대훈;이운용;김하나
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-280
    • /
    • 2007
  • In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

Recent Advances in Scanning Acoustic Microscopy for Adhesion Evaluation of Thin Films

  • Ju, Hyeong-Sick;Tittmann, Bernhard R.
    • 비파괴검사학회지
    • /
    • 제29권6호
    • /
    • pp.534-549
    • /
    • 2009
  • As the thin film technology has emerged in various fields, adhesion of the film interface becomes an important issue in terms of the longevity and durability of thin film devices. Diverse nondestructive methods utilizing acoustic techniques have been developed to assess the interfacial integrity. As an effective technique based on the ultrasonic wave focusing and the surface acoustic wave(SAW) generation, scanning acoustic microscopy(SAM) has been investigated for adhesion evaluation. Visualization of film microstructures and quantification of adhesion weakness levels by SAW dispersion are the recent achievements of SAM. To overcome the limitations in the theoretical dispersion model only suitable for perfectly elastic and isotropic materials, a new model has been more recently developed in consideration of film anisotropy and viscoelasticity and applied to the adhesion evaluation of polymeric films fabricated on semiconductive wafers.

리플로우 조건에 따른 Sn-52In 솔더범프의 전단응력과 전단에너지 비교 (Comparison of Shear Strength and Shear Energy for 48Sn-52In Solder Bumps with Variation of Reflow Conditions)

  • 최재훈;오태성
    • 마이크로전자및패키징학회지
    • /
    • 제12권4호통권37호
    • /
    • pp.351-357
    • /
    • 2005
  • 솔더/UBM 계면반응에 따른 솔더범프의 기계적 신뢰성을 평가하기 위한 방안으로서 Cu UBM 상에서 리플로우한 Sn-52In 솔더범프의 리플로우 조건에 따른 전단응력과 전단에너지의 변화거동을 비교하였다. 리플로우 조건에 따른 전단에너지의 변화거동이 전단강도에 비해 Sn-52In/Cu 계면반응 및 파괴모드의 변화거동과 훨씬 잘 일치하여 솔더/UBM 계면반응에 따른 기계적 신뢰성을 분석하는데 전단에너지가 전단강도보다 훨씬 효과적인 평가 방안임을 알 수 있었다.

  • PDF

원자력배관 건전성평가 전문가시스템 개발(II) -시스템 개발 및 사례해석- (Development of Nuclear Piping Integriry Expert System (II) -System Development and Case Studies-)

  • 전현규;허남수;김영진;박윤원;최영환
    • 대한기계학회논문집A
    • /
    • 제25권6호
    • /
    • pp.1015-1022
    • /
    • 2001
  • The objective of this paper is to develop an expert system called NPIES for nuclear piping integrity. This paper describes the structure and the development strategy of the NPIES system. The NPIES system consists of 3 part; the data input part, the analysis part and the output part. The data input part consists of the material properties database module and the suer interface module. The analysis part consists of the LEFM, CDFD, J/T, limit load modules and the 12 analysis routines for different cracks and loading conditions are provided respectively. Analysis results are presented to screen, printer and text file in the output part. Several case studies on circumferentially cracked piping were performed to evaluate the accuracy and the usefulness of the code. Maximum piping loads predicted by the NPIES system agreed well with those by the 3-dimensional finite element analysis. In addition, even if the material properties were not fully given, the NPIES system provided reasonable evaluation results with the predicted material properties inferred from the material properties database module.

Evaluation of tissue ingrowth and reaction of a porous polyethylene block as an onlay bone graft in rabbit posterior mandible

  • Sosakul, Teerapan;Tuchpramuk, Pongsatorn;Suvannapruk, Waraporn;Srion, Autcharaporn;Rungroungdouyboon, Bunyong;Suwanprateeb, Jintamai
    • Journal of Periodontal and Implant Science
    • /
    • 제50권2호
    • /
    • pp.106-120
    • /
    • 2020
  • Purpose: A new form of porous polyethylene, characterized by higher porosity and pore interconnectivity, was developed for use as a tissue-integrated implant. This study evaluated the effectiveness of porous polyethylene blocks used as an onlay bone graft in rabbit mandible in terms of tissue reaction, bone ingrowth, fibrovascularization, and graft-bone interfacial integrity. Methods: Twelve New Zealand white rabbits were randomized into 3 treatment groups according to the study period (4, 12, or 24 weeks). Cylindrical specimens measuring 5 mm in diameter and 4.5 mm in thickness were placed directly on the body of the mandible without bone bed decortication, fixed in place with a titanium screw, and covered with a collagen membrane. Histologic and histomorphometric analyses were done using hematoxylin and eosin-stained bone slices. Interfacial shear strength was tested to quantify graft-bone interfacial integrity. Results: The porous polyethylene graft was observed to integrate with the mandibular bone and exhibited tissue-bridge connections. At all postoperative time points, it was noted that the host tissues had grown deep into the pores of the porous polyethylene in the direction from the interface to the center of the graft. Both fibrovascular tissue and bone were found within the pores, but most bone ingrowth was observed at the graft-mandibular bone interface. Bone ingrowth depth and interfacial shear strength were in the range of 2.76-3.89 mm and 1.11-1.43 MPa, respectively. No significant differences among post-implantation time points were found for tissue ingrowth percentage and interfacial shear strength (P>0.05). Conclusions: Within the limits of the study, the present study revealed that the new porous polyethylene did not provoke any adverse systemic reactions. The material promoted fibrovascularization and displayed osteoconductive and osteogenic properties within and outside the contact interface. Stable interfacial integration between the graft and bone also took place.

채용시장 직무와 역량 간 미스매치 해소를 위한 플랫폼 개발 (Development of a Platform to resolve the Mismatch between Job and Competence in Recruitment Market)

  • 김종호
    • 디지털산업정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.11-24
    • /
    • 2016
  • The purpose of this study is to develop a recruiting platform resolving the mismatch between corporate job and job finder's competence in recruitment market. For this, we investigated technological trends and limitation on recruit platform. Based on the findings, this study investigates the trends and directions related to recruiting platform evolution and identified critical success factors and development strategies for successful development of recruiting platform. Two development strategies include employment of online resume and construction of database assessing job finder's competence. We also proposed target system architecture incorporating job database, competency assessment form, capability oriented resume. To analyze user requirement national competency standards and core job capability evaluation model were analyzed. Next, we designed integrated database, user interfaces, and dynamic functionalities using the forms developed in earlier stage. Finally, we assessed the fidelity of form item, integrity of database, and the usability of interface to evaluate the effectiveness of the system.