• Title/Summary/Keyword: interaction force

Search Result 1,330, Processing Time 0.034 seconds

Evaluation of Global Force and Interaction Body Force Density in Permanent Magnet Employing Virtual Air-gap Concept (가상공극개념을 이용한 연구자석의 전체전자기력과 상호체적력밀도 계산)

  • Lee, Se-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.278-284
    • /
    • 2009
  • The global force and interaction body force density were evaluated in permanent magnets by using the virtual air-gap scheme incorporating the finite-element method. Until now, the virtual air-gap concept has been successfully applied to calculate a contact force and a body force density in soft magnetic materials. These force calculating methods have been called as generalized methods such as the generalized magnetic charge force density method, the generalized magnetizing current force density method, and the generalized Kelvin force density method. For permanent magnets, however, there have been few research works on a contact force and a force density field. Unlike the conventional force calculating methods resulting in surface force densities, the generalized methods are novel methods of evaluating body force density. These generalized methods yield the actual total force, but their distributions have an irregularity, which seems to be random distributions of body force density. Inside permanent magnets, however, a smooth pattern was obtained in the interaction body force density, which represents the interacting force field among magnetic materials. To evaluate the interaction body force density, the intrinsic force density should be withdrawn from the total force density. Several analysis models with permanent magnets were tested to verify the proposed methods evaluating the interaction body force density and the contact force, in which the permanent magnet contacts with a soft magnetic material.

Estimation of Pipeline.Soil Interaction Force for the Response Analysis of Buried Pipeline (지중매설관로의 거동특성 해석을 위한 관.지반 상호작용력의 산정)

  • 김태욱;임윤묵;김문겸
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.57-67
    • /
    • 2003
  • Response analysis of buried pipeline subjected to permanent ground deformation(PGD) due to liquefaction is mainly executed by use of numerical analysis or semi-analytical relationship, When applying these methods, so called interfacial pipelineㆍsoil interaction force plays an dominant part. Currently used interaction force is mode up of indispensable mechanical and physical components for the response analysis of buried pipeline. However, it has somewhat limited applicability to the liquefied region since it is based on the experimental results for the non-liquefied region. Therefore, in this study, improved type of pipelineㆍsoil interaction force is proposed based on the existing interaction force and experimental research accomplishments. Above all, proposed interaction force includes various patterns of PGD or spatial distributions of interaction force caused by the decrease of soil stiffness. Through the comparison of numerical results using the proposed and the existing interaction force, relative influences of interaction force on the response of pipeline are evaluated and noticeable considerations in the application of semi-analytical relationship are discussed. Moreover, analyses due to the change of pipe thickness and burial depth are performed.

Soil-structure interaction and axial force effect in structural vibration

  • Gao, H.;Kwok, K.C.S.;Samali, B.
    • Structural Engineering and Mechanics
    • /
    • v.5 no.1
    • /
    • pp.1-19
    • /
    • 1997
  • A numerical procedure for dynamic analysis of structures including lateral-torsional coupling, axial force effect and soil-structure interaction is presented in this study. A simple soil-structure system model has been designed for microcomputer applications capable of reflecting both kinematic and inertial soil-foundation interaction as well as the effect of this interaction on the superstructure response. A parametric study focusing on inertial soil-structure interaction is carried out through a simplified nine-degree of freedom building model with different foundation conditions. The inertial soil-structure interaction and axial force effects on a 20-storey building excited by an Australian earthquake is analysed through its top floor displacement time history and envelope values of structural maximum displacement and shear force.

Comparison of laser technology & strain gauge application technology for measurement of interaction force between wheel and rail (차륜/레일 작용력 측정을 위한 레이저기술과 스트레인게이지 응용기술 비교)

  • Ham Young-Sam;Chung Woo-Jin;Sea Jung-Won
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.219-223
    • /
    • 2004
  • Korea Railroad Research Institute(KRRI) propelled sensing and measurement techniques development for measure of Lateral Force and Vertical Force With Italy to international cooperation research project for laser technology for measurement of wheel/rail interaction force. In this paper, we compared the laser technology for measurement of wheel/rail interaction force with the existing method. And then, we suggests interaction force measurement system procedure of hereafter.

  • PDF

Experimental study on the interaction force between a permanent magnet and a superconducting roll stack

  • Wenxin Li;Tianhui Yang;Ying Xin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.1
    • /
    • pp.11-15
    • /
    • 2023
  • In recent years, the interaction force between a permanent magnet and a closed superconductor coil has been gradually investigated in depth. The principle and application potential of an energy storage/convertor composed of a magnet and a closed superconducting coil have been proved. However, the study on the force between a magnet and a non-closed superconducting coil (superconducting roll stack) has hardly been reported in previous literature. The behavior of this kind of interaction and its influence to the interaction force between a permanent and a closed superconducting coil are also still unclear. In this paper, first we investigated the interaction force between a magnet and a superconducting roll stack. Then, a series of experiments were designed and conducted to clarify the factors affected the interaction force, including the geometrical parameters of the superconducting roll stack and the magnetic field density at the roll stack. Moreover, the comparison of the interaction forces between the magnet and roll stack or a closed coil was also introduced.

Estimation of Vertical Interaction Force to the End of a Surgical Instrument by Measuring Reaction Force to the Trocar Support (트로카 고정부에 작용하는 반력을 측정하여 수술도구 말단의 수직방향 상호작용 힘을 추정하는 방법)

  • Kim, Suyong;Kim, Cheongjun;Lee, Doo Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.615-618
    • /
    • 2016
  • This paper proposes a method to estimate vertical interaction force to the end of the surgical instrument by measuring reaction force at the part supporting the trocar. Relation between the force to the trocar and the interaction force is derived using the beam theory. The vertical interaction force is modeled as a function of the reaction force to the trocar and the distance between the drape plate and the trocar. Experimental results show that error is induced by the asymmetric shape of the trocar tip because contact position between the instrument and the trocar tip is changed depending on the direction of the interaction force. The theoretical relation, therefore, is compensated and reduced. Average $L_2$ relative error of the estimated force in the x-direction and the y-direction is 5.81 % and 5.99 %, respectively.

A study on laser technology for measurement of wheel/rail interaction force (차륜/레일 작용력 측정을 위한 레이저기술 연구)

  • Ham Y. S.;Seo J. W.
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.674-678
    • /
    • 2003
  • This research is develop the sensing and measurement technology for measure that wheel/rail interaction force to use laser. Investigated existent laser measurement system, and examined transformation by load that action to wheel for achieve research purpose. A proposed to laser measurement system composition plan to analyze existent method that measure wheel/rail interaction force.

  • PDF

Study on The Estimation of Pipeline\ulcornerSoil Interaction Force during Transverse Permanent Ground Deformation (횡방향 영구지반변형 발생시 관$\cdot$지반 상호작용력의 산정에 관한 연구)

  • 김태욱;임윤묵;김문겸;장성희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.165-173
    • /
    • 2003
  • In this study, the applicability of currently used pipeline.soil interaction force and previously proposed analytical relationship for the response analysis of buried pipeline subjected to transverse permanent ground deformation (PGD) due to liquefaction is evaluated. Based on meaningful contemplation, the improvement of interaction force and proposition of analytical relationship is made. Improved interaction force includes various patterns of PGD or spatial distributions of interaction force caused by the decrease of soil stiffness, and proposed relationship based on improved formula is applicable without regard to the width of PGD. Through the comparison of numerical results by use of commercial FEM program, the rational applicability of proposed relationship is objectively confirmed.

  • PDF

Unified Approach for Force/Position Control in the Vehicle Body Sanding Process

  • Nguyen, Chi Thanh;Lee, Jae Woo;Yang, Soon Yong
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.25-31
    • /
    • 2017
  • This study presents a methodology for simulating a unified approach that controls interaction force between tool and objective by using a synthesis method of robot interacting control law for stabilizing the transient process of motion. Root locus is used to analyze stabilization of motion deviation characteristics. Based on responses of motion deviation, contact force is derived to satisfy exponential stability and we generate control input with respect to motion trajectories and interaction force. Moreover, simulation is applied to experimental application of a Cartesian robot driven by two stepper motors, and the noise of feedback signals is considered as presence of system inaccuracies, and the unified approach of interaction force control is examined precisely.

Experimental Studies of Balancing Control of a Two-wheel Mobile Robot for Human Interaction by Angle Modification (이륜 구동 로봇의 균형 각도 조절을 통한 사람과의 상호 제어의 실험적 연구)

  • Lee, Seung Jun;Jung, Seul
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.2
    • /
    • pp.67-74
    • /
    • 2013
  • This paper presents interaction force control between a balancing robot and a human operator. The balancing robot has two wheels to generate movements on the plane. Since the balancing robot is based on position control, the robot tries to maintain a desired angle to be zero when an external force is applied. This leads to the instability of the system. Thus a hybrid force control method is employed to react the external force from the operator to guide the balancing robot to the desired position by a human operator. Therefore, when an operator applies a force to the robot, desired balancing angles should be modified to maintain stable balance. To maintain stable balance under an external force, suitable desired balancing angles are determined along with force magnitudes applied by the operator through experimental studies. Experimental studies confirm the functionality of the proposed method.