• Title/Summary/Keyword: inter-laboratory test

검색결과 65건 처리시간 0.032초

제동 라이닝애 대한 시험소간 비교에 의한 숙련도시험 (Proficiency Testing by Inter-Laboratory Comparisons for Braking Lining)

  • 정종덕;권성태;홍용기;김원경
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.586-591
    • /
    • 2003
  • This paper describes the result of proficiency testing by inter-laboratory comparisons for braking lining. Proficiency testing provides an objective means of assessing and demonstrating the validity and reliability of test results produced by laboratories. To more accuracy comparison test for braking lining test, they will be made the same test procedure and environment conditions.

  • PDF

Efficient Inter Prediction Mode Decision Method for Fast Motion Estimation in High Efficiency Video Coding

  • Lee, Alex;Jun, Dongsan;Kim, Jongho;Choi, Jin Soo;Kim, Jinwoong
    • ETRI Journal
    • /
    • 제36권4호
    • /
    • pp.528-536
    • /
    • 2014
  • High Efficiency Video Coding (HEVC) is the most recent video coding standard to achieve a higher coding performance than the previous H.264/AVC. In order to accomplish this improved coding performance, HEVC adopted several advanced coding tools; however, these cause heavy computational complexity. Similar to previous video coding standards, motion estimation (ME) of HEVC requires the most computational complexity; this is because ME is conducted for three inter prediction modes - namely, uniprediction in list 0, uniprediction in list 1, and biprediction. In this paper, we propose an efficient inter prediction mode (EIPM) decision method to reduce the complexity of ME. The proposed EIPM method computes the priority of all inter prediction modes and performs ME only on a selected inter prediction mode. Experimental results show that the proposed method reduces computational complexity arising from ME by up to 51.76% and achieves near similar coding performance compared to HEVC test model version 10.1.

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • 한국전문물리치료학회지
    • /
    • 제22권4호
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

철도차량용 디스크 브레이크 라이닝의비교시험 연구 (A Study on Comparison Test of Disk Brake Lining for Rolling Stock (KRRI -CARS))

  • 홍용기;권성태;정종덕;김정남
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.483-488
    • /
    • 2004
  • The inter-laboratory comparison test which is demanded on the authorized test of ISO/IEC 17025 is the program to guarantee the confidence of test result. This paper, as a part of the inter-laboratory comparison test between South Korea and China, is refered to the characteristic of friction coefficient of disk brake lining for rolling stock according to disk type. Brake tests were carried out under constant brake force and operating sequence by using dynamo-tester according to disk and disk lining types. To establishing the confidence of test result, we calculated A type uncertainty about friction coefficient and investigated the factors about the variation of friction coefficient.

  • PDF

Yield stress measurements in suspensions: an inter-laboratory study

  • Nguyen, Q. Dzuy;Akroyd, Timothy;Kee, Daniel C. De;Zhu, Lixuan
    • Korea-Australia Rheology Journal
    • /
    • 제18권1호
    • /
    • pp.15-24
    • /
    • 2006
  • The first international inter-laboratory study, involving six laboratories, has been conducted to examine issues associated with yield stress measurements in suspensions. The initial focus of the project was to evaluate the reliability and reproducibility of several common yield stress measuring techniques employed in different laboratories and with different instruments. Aqueous suspensions of colloidal $TiO_2$ at concentrations of 40-70 wt% solids were used as the test fluids. A wide range of instruments and techniques employing both direct and indirect methods were used to determine the yield stress of the samples prepared according to a prescribed procedure. The results obtained indicated that although variations of results existed among different techniques, direct yield stress measurements using static methods produced more reliable and repeatable results than other methods. Variability of the yield stress measured using different techniques within any laboratory however was less significant than variability of the results among different laboratories. The nature and condition of the test suspensions was identified as the most likely factor responsible for the poor reproducibility of yield stress measurements from different laboratories.

Inter-laboratory Comparison of Stable Carbon and Nitrogen Isotopic Composition Data Using Elemental Analyzer-isotope Ratio Mass Spectrometers

  • Kim, Jung-Hyun;Kang, Sujin;Bong, Yeon-Sik;Park, Kwangkyu;Kang, Tae-Woo;Park, Yong-Se;Kim, Dahae;Choi, Seunghyun;Joo, Young Ji;Choi, Bohyung;Nam, Seung-Il;Lee, Sang-Mo;Shin, Kyung-Hoon
    • 환경분석과 독성보건
    • /
    • 제21권4호
    • /
    • pp.229-236
    • /
    • 2018
  • In this study, inter-laboratory comparison was done using elemental analyzer-isotope ratio mass spectrometers (EA-IRMSs) to determine carbon and nitrogen contents as well as stable carbon and nitrogen isotopic compositions (${\delta}^{13}C$ and ${\delta}^{15}N$) of five environmental samples containing lake and marine sediments, higher plant leaves, and fish muscle, and one organic analytical standard (Protein (Casein) Standard OAS). Five national laboratories participated in this comparison study, and each laboratory analyzed all five samples and the analytical standard. Results showed that variations in total organic carbon (TOC) and total nitrogen (TN) contents as well as ${\delta}^{13}C_{TOC}$ and ${\delta}^{15}N_{TN}$ values among the laboratories were large compared to the analytical uncertainties. The results highlighted the inhomogeneity of the test samples and thus, the need to select suitable standard reference materials for future inter-laboratory studies. Further inter-laboratory comparison exercises could promote good measurement practices in the acquisition of stable carbon and nitrogen isotopic composition data.

고속액체크로마토그라피법을 이용한 사람 혈장 중 알리벤돌(Alibendol)의 정량 및 검증 (Determiniation and Validation of Alibendol using High Pressure Liquid Chromatography in Human plasma)

  • 송현호;유지영;김보겸;박현주;최광식;권영이
    • 약학회지
    • /
    • 제54권4호
    • /
    • pp.295-299
    • /
    • 2010
  • The aim of this study was to develop and validate for determination of alibendol in human plasma by HPLC method. After precipitation of 500 ${\mu}l$ plasma samples by 50% methanol 50 ${\mu}l$ and 60% perchloric acid 30 ${\mu}l$ and the supernatant 50 ${\mu}l$ was injected into HPLC. The assay was performed isocratically using 10 mM potassium phosphate (pH 3.0) and acetonitrile (80 : 20, v/v) as mobile phase. The $C_{18}$ column (particle size $3.5{\mu}m$, $4.6{\times}50$ mm, Zorbax Eclipse) was used as a solid phase. The mobile phase was delivered at a flow-rate of 1.7 ml/min, detection was by ultraviolet absorption at 232 nm and concentrations were calculated on the basis of peak areas. In these conditions, alibendol can be separated from ethylparaben, the internal standard, and endogenous substances. The retention times of alibendol and ethylparaben were just about 2.6 and 3.5 minutes, respectively. This rapid HPLC method was validated by examining the precision and accuracy for inter- and intra-day analysis. The standard curve was linear ($R^2$=1.0000) over the concentration range of 0.05~20 ${\mu}g$/ml. The inter-day relative standard deviation (R.S.D.) and accuracy were 0.2~12.2% and 94.4~101.2% (82.7% at the lower limit of quatitation). The intra-day R.S.D. and accuracy were 0.1~11.8% and 98.8~102.5%, respectively. The method was successfully applied to the determination of alibendol in plasma for a pharmacokinetic study.

국내 서식 담수새우 새뱅이(Neocaridina denticulata)를 이용한 3,4-Dichloroaniline의 급성독성 교차시험(Ring test) (Ring Test as Acute Toxicity Test with Korean Freshwater Shrimp, Neocaridina denticulata using 3,4-Dichloroaniline)

  • 신유진;이재우;김지은;조재구;김자현;강민호;김경태;김필제;박경화
    • 한국환경보건학회지
    • /
    • 제45권3호
    • /
    • pp.285-294
    • /
    • 2019
  • Objectives: For suitable risk management of the domestic aquatic environment, it is necessary to conduct toxicity tests using species native to Korea. In the present study, we performed toxicity ring tests using endemic freshwater arthropoda Neocaridina denticulata and evaluated its validity and reproducibility as an international standard test species. Methods: To evaluate the sensitivity levels of N. denticulata to hazardous chemicals, toxicity values for several chemicals were compared with other standard test species. Intra- and inter-laboratory acute toxicity tests were performed both within a single laboratory and among four laboratories respectively using 3,4-Dichloroaniline, which is generally used as a reference test substance in fish toxicity tests. In addition, intra- and inter-laboratory coefficient of variations (CVs) were calculated to evaluate reproducibility based on the estimated toxicity values. Results: The sensitivity of N. denticulata to several chemicals was found to be similar with D. manga, indicating that the species is valid as a test species. The CVs of the intra- and inter-laboratory tests were 22.946% with four qualified runs and 8.828% among the four laboratories, respectively. Conclusions: N. denticulata serves in an important role in the food chain of Korean aquatic ecosystems and also inhabits several other Asian countries. Since the validity and reproducibility of the species were confirmed as a toxicity test species in this study, further efforts are needed to establish N. denticulata as the international standard test species for the appropriate risk assessment of aquatic ecosystems at home and abroad.

다이옥신 정도 관리용 CRM 제조와 실험실간 비교평가 (Preparation of a CRM for QA/QC in dioxin analysis and inter-laboratory study)

  • 유병운;문영훈;김민관;경종대;장윤석
    • 분석과학
    • /
    • 제17권2호
    • /
    • pp.153-162
    • /
    • 2004
  • 생활 폐기물 소각장에서 채취한 비산재를 이용하여 다이옥신 정도 관리용 인증표준물질(CRM)을 제조하였고 이를 이용하여 실시된 실험실 간 비교 평가가 실시되었다. 채취된 비산재는 여러 번의 균질화 과정을 거쳤으며 균질성 시험은 ISO Guide 35에 따른 일원분산분석을 통해 이루어졌고 제조된 CRM에 대한 불확도 평가를 수행하였다. 각 기관의 비산재 농도값과 CRM 농도값을 비교 해 본 결과 polychlorinated dibenzo-p-dioxins (PCDDs)는 대부분의 기관이 CRM에 비해 낮은 값을 보였으며 polychlorinated dibenzofurans (PCDFs)는 대부분의 기관에서 높은 값을 보였다. 추출액의 경우 이성체 별로 정도의 차이는 있지만 대부분의 기관에서 평균에 가까운 값을 나타냈다.

능동형 기지국안테나의 PIMD 특성분석 (PIMD Performance Test of Active Baseband Antenna)

  • 김재학;정영배
    • 전기전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.163-167
    • /
    • 2013
  • 이동 통신 서비스가 확대됨에 따라 인접 기지국 간의 간섭 문제가 증가하게 되었으며, 이에 따라 이동통신 시스템의 수동 상호변조왜곡(PIMD: Passive Inter-Modulation Distortion)에 대한 문제가 크게 대두되고 있다. 본 논문에서는 기존의 수동형 안테나구조에서 증폭기 등의 핵심 능동부가 기지국안테나의 방사소자에 직접 연결되는 안테나 일체형 능동안테나에 대한 새로운 PIMD 특성시험 방안을 제안하고 이에 대한 시험결과를 제시한다. 제안된 시험결과 통하여, 능동형 기지국안테나는 기존의 수동형 구조에 비하여 약 8.4dB의 PIMD 개선효과를 가지며, 제안된 PIMD 시험방식은 기지국안테나가 실제 기지국에서 운용되는 환경에 근접하게 시행됨으로써 보다 정확한 시험결과를 도출할 수 있을 것으로 판단된다.