• Title/Summary/Keyword: inter-laboratory study

Search Result 167, Processing Time 0.02 seconds

Inter-Conversion Matrix for Transcoding Block DCT and DWT-Based Compressed Images

  • Kim, Donggyun;Lim, Sanghee;Paik, Joonki
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.3
    • /
    • pp.103-109
    • /
    • 2014
  • This study derived the inter-conversion matrices, which can be used in heterogeneous image transcoding between the compressed images using different transforms, such as the $8{\times}8$ block discrete cosine transform (BDCT) and the one-level discrete wavelet transform (DWT). Basically, to obtain the one-level DWT coefficients from $8{\times}8$ BDCT, inverse BDCT should be performed followed by forward DWT, and vice versa. On the other hand, if the proposed interconversion approach is used, only one inter-conversion matrix multiplication makes the corresponding transcoding possible. Both theoretical and experimental analyses showed that the amount of computation of the proposed approach decreases over 20% when the inter-conversion matrices are used under specific conditions.

Inter-laboratory Comparison of Stable Carbon and Nitrogen Isotopic Composition Data Using Elemental Analyzer-isotope Ratio Mass Spectrometers

  • Kim, Jung-Hyun;Kang, Sujin;Bong, Yeon-Sik;Park, Kwangkyu;Kang, Tae-Woo;Park, Yong-Se;Kim, Dahae;Choi, Seunghyun;Joo, Young Ji;Choi, Bohyung;Nam, Seung-Il;Lee, Sang-Mo;Shin, Kyung-Hoon
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.229-236
    • /
    • 2018
  • In this study, inter-laboratory comparison was done using elemental analyzer-isotope ratio mass spectrometers (EA-IRMSs) to determine carbon and nitrogen contents as well as stable carbon and nitrogen isotopic compositions (${\delta}^{13}C$ and ${\delta}^{15}N$) of five environmental samples containing lake and marine sediments, higher plant leaves, and fish muscle, and one organic analytical standard (Protein (Casein) Standard OAS). Five national laboratories participated in this comparison study, and each laboratory analyzed all five samples and the analytical standard. Results showed that variations in total organic carbon (TOC) and total nitrogen (TN) contents as well as ${\delta}^{13}C_{TOC}$ and ${\delta}^{15}N_{TN}$ values among the laboratories were large compared to the analytical uncertainties. The results highlighted the inhomogeneity of the test samples and thus, the need to select suitable standard reference materials for future inter-laboratory studies. Further inter-laboratory comparison exercises could promote good measurement practices in the acquisition of stable carbon and nitrogen isotopic composition data.

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

Yield stress measurements in suspensions: an inter-laboratory study

  • Nguyen, Q. Dzuy;Akroyd, Timothy;Kee, Daniel C. De;Zhu, Lixuan
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.1
    • /
    • pp.15-24
    • /
    • 2006
  • The first international inter-laboratory study, involving six laboratories, has been conducted to examine issues associated with yield stress measurements in suspensions. The initial focus of the project was to evaluate the reliability and reproducibility of several common yield stress measuring techniques employed in different laboratories and with different instruments. Aqueous suspensions of colloidal $TiO_2$ at concentrations of 40-70 wt% solids were used as the test fluids. A wide range of instruments and techniques employing both direct and indirect methods were used to determine the yield stress of the samples prepared according to a prescribed procedure. The results obtained indicated that although variations of results existed among different techniques, direct yield stress measurements using static methods produced more reliable and repeatable results than other methods. Variability of the yield stress measured using different techniques within any laboratory however was less significant than variability of the results among different laboratories. The nature and condition of the test suspensions was identified as the most likely factor responsible for the poor reproducibility of yield stress measurements from different laboratories.

Experimental study on seismic behavior of two-storey modular structure

  • Liu, Yang;Chen, Zhihua;Liu, Jiadi;Zhong, Xu
    • Steel and Composite Structures
    • /
    • v.37 no.3
    • /
    • pp.273-289
    • /
    • 2020
  • Due to the unique construction method of modular steel buildings (MSBs) with units prefabricated fully off the site and assembled quickly on the site, the inter-module connection for easy operation and overall performance of the system were key issues. However, it was a lack of relevant research on the system-level performance of MSBs. This study investigated the seismic performance of two-storey modular steel structure with a proposed vertical rotary inter-module connection. Three full-scale quasi-static tests, with and without corrugated steel plate and its combination, were carried out to evaluate and compare their seismic behaviour. The hysteretic performance, skeleton curves, ductile performance, stiffness degradation, energy dissipation capacity, and deformation pattern were clarified. The results showed that good ductility and plastic deformation ability of such modular steel structures. Two lateral-force resistance mechanisms with different layout combinations were also discussed in detail. The corrugated steel plate could significantly improve the lateral stiffness and bearing capacity of the modular steel structure. The cooperative working mechanism of modules and inter-module connections was further analyzed. When the lateral stiffness of upper and lower modular structures was close, limited bending moment transfer may be considered for the inter-module connection. While a large lateral stiffness difference existed initially between the upper and lower structures, an obvious gap occurred at the inter-module connection, and this gap may significantly influence the bending moments transferred by the inter-module connections. Meanwhile, several design recommendations of inter-module connections were also given for the application of MSBs.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Global seismic damage assessment of high-rise hybrid structures

  • Lu, Xilin;Huang, Zhihua;Zhou, Ying
    • Computers and Concrete
    • /
    • v.8 no.3
    • /
    • pp.311-325
    • /
    • 2011
  • Nowadays, many engineers believe that hybrid structures with reinforced concrete central core walls and perimeter steel frames offer an economical method to develop the strength and stiffness required for seismic design. As a result, a variety of such structures have recently been applied in actual construction. However, the performance-based seismic design of such structures has not been investigated systematically. In the performance-based seismic design, quantifying the seismic damage of complete structures by damage indices is one of the fundamental issues. Four damage states and the final softening index at each state for high-rise hybrid structures are suggested firstly in this paper. Based on nonlinear dynamic analysis, the relation of the maximum inter-story drift, the main structural characteristics, and the final softening index is obtained. At the same time, the relation between the maximum inter-story drift and the maximum roof displacement over the height is also acquired. A double-variable index accounting for maximum deformation and cumulative energy is put forward based on the pushover analysis. Finally, a case study is conducted on a high-rise hybrid structure model tested on shaking table before to verify the suggested quantities of damage indices.

Shuffled Discrete Sine Transform in Inter-Prediction Coding

  • Choi, Jun-woo;Kim, Nam-Uk;Lim, Sung-Chang;Kang, Jungwon;Kim, Hui Yong;Lee, Yung-Lyul
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.672-682
    • /
    • 2017
  • Video compression exploits statistical, spatial, and temporal redundancy, as well as transform and quantization. In particular, the transform in a frequency domain plays a major role in energy compaction of spatial domain data into frequency domain data. The high efficient video coding standard uses the type-II discrete cosine transform (DCT-II) and type-VII discrete sine transform (DST-VII) to improve the coding efficiency of residual data. However, the DST-VII is applied only to the Intra $4{\times}4$ residual block because it yields relatively small gains in the larger block than in the $4{\times}4$ block. In this study, after rearranging the data of the residual block, we apply the DST-VII to the inter-residual block to achieve coding gain. The rearrangement of the residual block data is similar to the arrangement of the basis vector with a the lowest frequency component of the DST-VII. Experimental results show that the proposed method reduces the luma-chroma (Cb+Cr) BD rates by approximately 0.23% to 0.22%, 0.44% to 0.58%, and 0.46% to 0.65% for the random access, low delay B, and low delay P configurations, respectively.

Inter-scale Observation and Process Optimization for Guanosine Fermentation

  • Chu, Ju;Zhang, Si-Liang;Zhuang, Ying-Ping
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 2005.06a
    • /
    • pp.233-244
    • /
    • 2005
  • Guanosine fermentation process can be well predicted and analyzed by the proposed state equations describing the dynamic change of a bioreactor. Pyruvate and alanine were found to be characteristically accumulated along with the decline of the guanosine formation rate during the mid-late phase of the process. The enzymological study of the main pathways in glucose catabolism and the quantitative stoichiometric calculation of metabolic flux distribution revealed that it was entirely attributed to the shift of metabolic flux from hexose monophosphate (HMP) pathway to glycolysis pathway. The process optimization by focusing on the restore of the shift of metabolic flux was conducted and the overcoming the decrease of oxygen uptake rate (OUR) was taken as the relevant factor of the trans-scale operation. As a result, the production of guanosinewas increased from 17 g/L to over 34 g/I.

  • PDF

Power Control with Nearest Neighbor Nodes Distribution for Coexisting Wireless Body Area Network Based on Stochastic Geometry

  • Liu, Ruixia;Wang, Yinglong;Shu, Minglei;Zhao, Huiqi;Chen, Changfang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.11
    • /
    • pp.5218-5233
    • /
    • 2018
  • The coexisting wireless body area networks (WBAN) is a very challenging issue because of strong inter-networks interference, which seriously affects energy consumption and spectrum utilization ratio. In this paper, we study a power control strategy with nearest neighbor nodes distribution for coexisting WBAN based on stochastic geometry. Using homogeneous Poisson point processes (PPP) model, the relationship between the transmission power and the networks distribution is analytically derived to reduce interference to other devices. The goal of this paper is to increase the transmission success probability and throughput through power control strategy. In addition, we evaluate the area spectral efficiency simultaneously active WBAN in the same channel. Finally, extensive simulations are conducted to evaluate the power control algorithm.