• 제목/요약/키워드: inter-department rotation

검색결과 36건 처리시간 0.025초

간호사의 근무부서 이동이 직무동기, 조직몰입에 미치는 영향 (A study on the relationships among inter-department rotation. job motivation and organizational commitment of nurses)

  • 유문숙;김용순
    • 간호행정학회지
    • /
    • 제5권2호
    • /
    • pp.225-235
    • /
    • 1999
  • This study was conducted to offer a basic material for effective human resource management of nurses by studying correlations among inter-department rotation, job motivation and organizational commitment. For this study 159 nurses in a medical college hospital were surveyed. Organization Assessment Instrument(Van de Ven. 1980) and Organizational Commitment Questionnaire (Mowday, 1979) were used. SPSS was used to analyze the data. The results of this study are as follows : 1. Nurses who had been rotated to other departments showed higher motivation scores than those who had not. 2. Nurses who had been rotated also indicated higher organizational commitment scores than those who had not. 3. There was significant positive correlations among nurse's age, job motivation and organizational commitment of nurses. 4. There was significant positive correlations among nurse's experience, job motivation and organizational commitment of nurses. 5. Inter-department rotation times were significant positive correlation with job motivation. 6. "The sense of achievement perceived form performing one's duty" was the most important criteria that nurses consider in measuring their job motivation. As to the criteria for inter-department rotation, some respondents stated that it is needed when "current assignments are not suited for particular individuals" and such rotations would job motivation and elevate the morale of nurses involved." Many opposed using the rotations as a "means of reprimanding individuals." In conclusion, inter-department rotation has a positve effect on the nurse's job motivation and organizational commitment, so regular inter-department rotation have to be recommended to nurses who want rotation.

  • PDF

Inter-rater Reliability of Cervical Proprioception, Dynamic Balance and Dorsiflexion Range of Motion Ising STARmat®

  • Park, Ji-Won;Park, Seol
    • The Journal of Korean Physical Therapy
    • /
    • 제32권2호
    • /
    • pp.88-93
    • /
    • 2020
  • Purpose: This study examined the inter-rater reliability of cervical proprioception, dynamic balance ability, and ankle dorsiflexion range of motion using STARmat®, which is a practical clinical tool that can provide practitioners and patients with quantitative and qualitative results. Methods: Thirty healthy young subjects were enrolled in this study, and two well-trained physical therapists participated as a tester. Two testers measured the cervical joint position error at the starting position after neck flexion, extension, side bending, and rotation; three dynamic balance tests, including anterior excursion, anterior reaching with single leg balance, and posterior diagonal excursion; and ankle dorsiflexion range of motion using STARmat®. The intra-class correlation coefficient (ICC) was used to determine the inter-rater reliability of the tests. Results: The inter-rater reliability for the cervical proprioception ranged from moderate to good (0.66 to 0.83), particularly for flexion (0.82), extension (0.70), right side bending (0.73), left side bending (0.71), right rotation (0.83), and left rotation (0.66). For the dynamic balance, the inter-rater reliability ranged from good to excellent (0.87 to 0.91), particularly for anterior excursion (0.86), posterior diagonal excursion (0.87 to 0.89), and anterior reaching with a single leg balance (0.90 to 0.91). In addition, for the ankle dorsiflexion range of motion, the ICC for the inter-rater reliability ranged from 0.95 to 0.96. Conclusion: STARmat® is a reliable tool for measuring cervical proprioception, dynamic balance tests, and ankle dorsiflexion range of motion in healthy young adults.

Coherent director rotation and memory effects, and their dependence on the morphology of the constituent molecules in thiol-ene polymer stabilized ferroelectric liquid crystal system

  • Lim, Tong-Kun;Lee, Ji-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.199-202
    • /
    • 2005
  • We have studied the origin of coherent director rotation [CDR] as well as memory behavior in thiol-ene polymer stabilized ferroelectric liquid crystal [FLC]. The ene constituents are found to be always located at the inter-layer space and induce the coherent director rotation motion of liquid crystal molecule. On the other hand, the thiols are more intersticed between ferroelectric liquid crystal molecules at intra-layer as the thiol gets longer, and these intersticed thiols enhance the multistability and the resolution of memory state of FLCs.

  • PDF

Three-dimensional stresses analysis in rotating thin laminated composite cylindrical shells

  • Ahmadi, Isa;Najafi, Mahsa
    • Steel and Composite Structures
    • /
    • 제22권5호
    • /
    • pp.1193-1214
    • /
    • 2016
  • In this paper, the 3D stress state and inter-laminar stresses in a rotating thin laminated cylinder shell are studied. The thickness of the cylinder is supposed to be thin and it is made of laminated composite material and can have general layer stacking. The governing equations of the cylindrical shell are obtained by employing the Layerwise theory (LWT). The effect of rotation is considered as rotational body force which is induced due to the rotation of the cylinder about its axis. The Layerwise theory (LWT), is used to discrete the partial differential equations of the problem to ordinary ones, in terms of the displacements of the mathematical layers. By applying the Free boundary conditions the solution of the governing equations is completed and the stress state, the inter-laminar stresses, and the edge effect in the rotating cylindrical shells are investigated in the numerical results. To verify the results, LWT solution is compared with the results of the FEM solution and good agreements are achieved. The inter-laminar normal and shear stresses in rotating cylinder are studied and effects of layer stacking and angular velocity is investigated in the numerical results.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권2호
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

정상 성인의 견, 고관절 가동범위에 대한 조사 (Shoulder and Hip Joint Range of Motion in Normal Adults)

  • 함용운
    • The Journal of Korean Physical Therapy
    • /
    • 제3권1호
    • /
    • pp.97-108
    • /
    • 1991
  • The purpose of this article is to know the standard figures of joint range of motion, in conjuction with age and sen, for normal adults. The results of assessment and analysis io shoulder and hip joint range of motion are as follows : 1) The average shoulder joint range of motion in normal adults are $160.5^{\circ}$ in flexion, $53.5^{\circ}$ in extension, $159.3^{\circ}$ in adduction, $62.3^{\circ}$ in internal rotation, $83.9^{\circ}$ in external rotation, The average hip joint range of motions are $116.8^{\circ}$ in flexion, $16.1^{\circ}$ in extension, $41.1^{\circ}$ in abduction, $33.8^{\circ}$ in abduction, $40.0^{\circ}$ in interne rotation, $41.2^{\circ}$ in external rotation. 2) There is no significant difference in shoulder and hip joint range of motion between male and female (p>0.05). 3) As to the inter-relation in age and range of motion, the left flexion and extension, internal rotation and right extension in shoulder joint is decreased gradually with increasing age, and left flexion (knee flexion, knee extension) and right flexion (knee extension) in hip joint is decreased with increasing age (p<0.01). 4) Relating to age and sex, the twenties male shows highest range of motion in shoulder and hip joint, with .the fifties female shows, lowest range of motion.

  • PDF

Reliability and Validity of Angle of Trunk Rotation Measurement Using Smartphone and 3D Printing Technology in Scoliosis

  • Geum-Dong Shin;Seong-gil Kim;Kyoung Kim
    • The Journal of Korean Physical Therapy
    • /
    • 제34권6호
    • /
    • pp.283-291
    • /
    • 2022
  • Purpose: The purpose of this study was to compare and analyze the method of measuring the angle of the trunk rotation using a smartphone with 3D smartphone holder compared to a scoliometer, which is a measuring tool used as a method for diagnosing scoliosis in scoliosis patients. Methods: Angle of trunk rotation was measured in 21 subjects diagnosed with scoliosis. scoliometer measurement method, a smartphone measurement method with a 3D smartphone holder, a smartphone blind measurement method with a 3D smartphone holder, a smartphone measurement method without a smartphone holder, a smartphone blind measurement method without a smartphone holder, and a total of five measurement methods were repeated three times for comparison and analysis. Results: The smartphone measurement method with a 3D smartphone holder has excellent intra-rater reliability of angle of trunk rotation (Rater A; ICC3, 2≥0.993, Rater B; ICC3, 2≥0.992). The smartphone blind measurement method with a 3D smartphone holder has excellent inter-rater reliability of angle of trunk rotation (ICC2, 2≥0.968). The scoliometer measurement method had the highest validity (r=0.976) with the smartphone measurement method with a 3D smartphone holder, and the blind measurement method without a smartphone holder had the lowest validity (r=0.886). Conclusion: These findings, the angle of trunk rotation measured by the smartphone measurement method with a 3D smartphone holder in scoliosis patients showed high reliability and validity compared to the scoliometer measurement method.

엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구 (The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient)

  • 박선욱;김명수;배효선;차용호
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

Circulation in the Central South Sea of Korea in Spring 1999

  • Lee, Jae-Chul;Lee, Sang-Ho;Kim, Dae-Hyun;Son, Yong-Tae;Perkins, Henry-T.;Kim, Jeong-Chang;Pang, Ig-Chan
    • Journal of the korean society of oceanography
    • /
    • 제38권3호
    • /
    • pp.143-155
    • /
    • 2003
  • Current and sea level were observed in spring 1999 by a bottom mounted ADCP and tide gauge in the central part of the South Sea of Korea. With respect to the front, the distribution of isotherms is prograde in the offshore region whereas that of isohalines is retrograde, especially in the coastal area. The combined effect results in shoaling of isopycnals at the front. This distribution corresponds to a westward coastal flow on the northern side of the front and the eastward Tsushima Warm Current (TWC) to the south, determined by vessel-mounted ADCP observations. The low-frequency current shows either alternating clockwise-counterclockwise rotation or else persistent eastward motion depending on the frontal motion. Fluctuations of wind, sea level and current are coherent at period of 3-4 days and show some characteristics of Ekman-like dynamics.

테니스 양손 백핸드 드라이브 스트로크 시 볼 방향성에 따른 수평회전운동 비교분석 (A Comparative Analysis of Horizontal Rotation Movements for Different Ball Course during Two-handed Backhand Drive Stroke in Tennis)

  • 서국은;정용민;강영택
    • 한국운동역학회지
    • /
    • 제25권3호
    • /
    • pp.293-300
    • /
    • 2015
  • Objective : The purpose of this study was to compare the kinematic data of the horizontal rotation movements of shoulder, hip, knee during two-handed backhand drive stroke according to two different ball directions. Methods : The kinematic variables were analyzed such as the joint angles of the lower body, horizontal rotation angles of the shoulder, hip, inter-knee segment, body twist angle and difference in angle of forward swing. Two-handed backhand drive stroke was analyzed through a three-dimensional motion analysis. The collected data were analyzed by a paired t-test, and the statistical significant value was set at ${\alpha}=.05$. Results : The findings of this study were as follows; First, there was no difference in the total angles of lower limb joints from the forward swing position to impact posterior. Second, there was no difference in the horizontal rotation angles of E1 shoulder, hip, and E2 shoulder but the horizontal rotation angles of E1 knee, E2 hip, knee, E3, and E4 shoulder, hip, and knee were different in all events. Third, there was no difference in the body twist angle of the maximum horizontal rotation. In addition, there was no difference in the angle of the body twist by the ball direction in the shoulder-hip, the hip-knee and the shoulder-knee. Conclusion : Horizontal rotation angle determines ball directions.