• 제목/요약/키워드: inter-color correlation

검색결과 22건 처리시간 0.024초

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

능률적 RGB 비디오 압축 부호화를 위한 잔여신호의 적응적 주파수-선택 가중 예측 기법 (An adaptive frequency-selective weighted prediction of residual signal for efficient RGB video compression coding)

  • 정진우;최윤식;김용구
    • 방송공학회논문지
    • /
    • 제15권4호
    • /
    • pp.527-539
    • /
    • 2010
  • 대부분의 비디오 부호화 시스템은 YCbCr 색 공간에서 부호화가 수행되나 초고화질 비디오가 사용되는 분야에서는 YCbCr 색 공간에서 부호화하는 것이 RGB 색 공간에서 부호화는 것에 비해 높은 압축 효율을 제공하지 않기 때문에 RGB 공간에서 부호화하는 것이 선호된다. RGB 비디오 신호의 압축 부호화 효율을 증대시키기 위하여 본 논문은 잔여신호의 적응적 주파수-선택 가중 예측 기법을 제안한다. RGB 비디오 신호의 색 평면간 상관도를 최대한 활용하기 위해, 제안 기법은 잔여신호 평면 사이의 주파수 영역에서의 부호 일치도와 상관 강도에 근거하여 적응적으로 잔여신호 평면 간 예측될 주파수 영역과 그에 상응하는 예측 가중치를 선택한다. 실험 결과는 최신의 비디오 압축 표준인 H.264/AVC에서 4:4:4 비디오 부호화의 공통 모드에 비해 약 13% 정도 압축 부호화 성능을 개선시켰음을 보여준다.

색 공간 내 중복 정보 감소를 위한 HEVC 스크린 콘텐츠 부호화 기법 성능 분석 (Performance Analysis of Screen Contents Coding Tools to Reduce Inter-Color Component Correlation)

  • 강제원
    • 방송공학회논문지
    • /
    • 제20권5호
    • /
    • pp.687-696
    • /
    • 2015
  • 최근 동영상 압축에 관한 국제 표준화 기구인 JCT-VC (Joint Collaborative Team on Video Coding) 에서는 High Efficiency Video Coding (HEVC)의 확장 표준으로 HEVC/Range Extension (HEVC/RExt)의 개발을 완료하고 스크린 콘텐츠 동영상의 부호화기술을 위한 표준인 HEVC/Screen Content Coding (HEVC/SCC)을 제정 중이다. 기존 동영상 압축 과정에서는 이미지 센서로부터 취득한 RGB 영상을 변환하여 부호화를 수행하는 반면에 애니매이션, 그래픽스 등 컴퓨터로 합성한 영상을 일컫는 스크린 콘텐츠의 경우는 색 공간의 변환이 주관적 화질을 심각하게 열화 시킬 수 있으므로 기존 RGB 색 공간을 유지하며 효율적으로 색 공간 내 정보의 중복성을 줄이기 위한 부호화 기법이 필요하다. 본 논문에서는 HEVC/RExt.와 HEVC/SCC에서 개발한 스크린 콘텐츠 동영상 압축을 위한 색 요소 예측 기법과 루프 내 색 공간 변환 기술의 성능을 분석한다. 실험 결과에 의하면 색 요소 예측 기법은 평균 약 11.7% BD-rate 감소, 색 공간 예측 기법은 평균 약 16.4% BD-rate 감소를 보인다. 그러나 두 기법이 동시에 적용되는 경우 약 18.2%의 BD-rate 감소를 보여 두 기법의 부호화 효율이 약 9.9% 중첩된다. 본 결과를 응용하여 두 기법이 배타적으로 선택이 되게끔 부호기 고속화를 수행하는 경우 약 0.3%의 부호화 손실로 93%의 부호화 측정 시간을 제공한다.

후두 발적에 대한 컴퓨터 평가 시스템의 신뢰도 연구 (Reliability of Computerized Measurement of Laryngeal Erythema)

  • 문병재;남순열;김상윤;최승호
    • 대한후두음성언어의학회지
    • /
    • 제16권1호
    • /
    • pp.19-22
    • /
    • 2005
  • Background and Objectives : While considerable progress has been made in enhancing the quality of laryngoscopy and image processing, the evaluation of laryngeal erythema is still based on the clinician's judgement. The purpose of this study is to quantitatively measure the degree of erythema and to examine the relationship with clinical grading. Materials and Methods : Color images of larynx from 100 subjects were captured from video-documented examinations of laryngoscopy. The amount of erythema within the digitized larynx image was quantified using software developed and was compared with a grading system (0 to 3 scale) based on visual inspection by 4 experienced clinicians. The results were compared by deriving Kappa, Kendall and Spearman statistic. Results : There was high intra-observer(R=0.402-0.755) and inter-observer correlation (R=0.789). Among parameters, the red composite value had most remarkable agreement with clinical grading(R=0.827). Conclusion : The result suggest that the computer based analysis of laryngeal erythema can provide quantiative data on degree of erythema and the basis for further development of an expert system.

  • PDF

채널 간 상관관계를 이용한 무손실 컬러 이미지 압축 (Lossless Color Image Compression using Inter-channel Correlation)

  • 김세윤;조남익
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2011년도 하계학술대회
    • /
    • pp.479-481
    • /
    • 2011
  • 기존의 무손실 압축은 일반적으로 채널간의 상관관계를 거의 이용하지 않고, 각각의 채널을 따로 압축하였다. 본 논문에서는 컬러 이미지가 갖는 채널 간의 상관관계를 이용하여 무손실 압축의 성능을 향상시키는 방법을 제안하였다. 제안하는 방법에서는 채널 간 상관관계를 표현할 수 있도록 비대칭 샘플링을 이용하여 모자이크 이미지와 나머지 이미지로 나누어 압축을 수행하였고, 압축된 모자이크 이미지의 정보를 이용해서 나머지 이미지를 예측하여 압축할 정보의 양을 감소시켰다. 압축 성능을 평가하는데 일반적으로 사용되는 데이터들에 대하여 실험한 결과, 기존의 압축표준인 JPEG2000 lossless에 대해 평균 4.75%의 성능 향상을 보여주었다.

  • PDF

천리안 해양위성 2호(GOCI-II) 임무 초기 해무 탐지 산출: 해무의 광학적 특성 및 초기 검증 (The GOCI-II Early Mission Marine Fog Detection Products: Optical Characteristics and Verification)

  • 김민상;박명숙
    • 대한원격탐사학회지
    • /
    • 제37권5_2호
    • /
    • pp.1317-1328
    • /
    • 2021
  • 본 연구는 천리안 해양위성 2호(GOCI-II)를 활용하여 개발된 해무 탐지 알고리즘의 초기 결과에 대한 분석을 수행하였다. GOCI-II 해무 탐지 성능을 확인하기 위해 1호와 2호가 중복으로 관측한 2020년 10월-2021년 3월 사이에 발생한 해무 사례에 대해 광학적 특성 분석을 실시하였다. 해무 탐지 알고리즘에 입력자료로 사용되는 412 nm 밴드 레일리 산란 보정 반사도(Rayleigh-corrected reflectance; Rrc)와 정규화된 국소 표준 편차(Normalized Local Standard Deviation; NLSD)를 GOCI, GOCI-II 자료를 시공간 일치시킨 뒤 분석한 결과 412 nm 밴드 레일리 Rrc의 경우 0.01의 평균 제곱근 오차 (Root Mean Squared Error; RMSE)와 0.998의 상관계수(correlation coefficient)을 나타내고, NLSD의 경우 0.007의 RMSE, 0.798의 correlation을 나타낸다. 해무와 구름이 갖는 광학적 특성을 분석하기 위해 천리안 해양위성 2호의 밴드 별 Rrc 값을 확인하였다. 구름의 경우 넓은 영역에서 높은 반사도를 보인 반면, 해무의 경우 모든 밴드에서 구름에 비해 상대적으로 반사도가 낮고 좁은 영역에 분포한다. 실제 해무 사례에 대해 GOCI와 GOCI-II 해무 탐지 알고리즘을 비교한 결과 전반적인 해무 탐지 성능은 크게 차이가 없으나 높아진 공간 해상도의 영향으로 해무 경계면에서 공간적으로 더 세밀한 탐지가 가능했다. 종관기상관측소 시정계 자료와 비교 분석하여 초기 자료에 대한 신뢰도를 조사하였다. 추후 충분한 샘플 확보로 인한 안정적인 성능 검증, 실시간 구름 정보 교체를 통한 후처리 과정 개선, 에어로졸 자료 추가로 해무 오탐지 감소를 통해 해무 탐지 알고리즘의 성능 향상이 기대된다.

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • 제17권3호
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Screening and detection of methylisothiazolinone and chloromethylisothiazolinone in cosmetics by UPLC-MS/MS

  • Lee, Ji Hyun;Paek, Ji Hyun;Park, Han Na;Park, Seongsoo;Kang, Hoil
    • 분석과학
    • /
    • 제33권3호
    • /
    • pp.125-133
    • /
    • 2020
  • Methylisothiazolinone (MIT) and chloromethylisothiazolinone (CMIT) cause allergic contact dermatitis and are banned cosmetics ingredients, except in rinse-off products. However, their presence has been detected in cosmetics. We report a UPLC-tandem MS/MS screening method for their simultaneous determination in cosmetics. To facilitate extraction from various matrices, pretreatment methods were developed for each sample type. The method was optimized through a series of assessments, including specificity, LOD, LOQ, linearity, recovery, stability, precision, and accuracy. The LODs and LOQs for MIT ranged from 0.054 and 0.163 ㎍ mL-1 whereas those for CMIT ranged from 0.040 and 0.119 ㎍ mL-1. The linear correlation coefficients (r2) were higher than 0.999. Relative standard deviations (RSDs) for both intra- and inter-day measurements ranged from 0.3 ~ 13.6 %. Recoveries at three different concentrations were within 87.9 ~ 118.9 %. The RSD for stability measurements of spiked samples was within 7 %. These results confirm the suitability of the developed method for the simultaneous quantitation of MIT and CMIT in cosmetics. Samples of 320 color cosmetics, including eyeshadows, solid lipsticks, liquid lipsticks, and nail polishes were analyzed using the developed method, and two of them were found to contain both MIT and CMIT and one of them was found to contain only MIT. This data and the method will aid the regulation of ingredients used in cosmetics.

A Deep Optical Photometric Study of the Massive Young Open Clusters in the Sagittarius-Carina Spiral Arm

  • Hur, Hyeonoh
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.44.1-44.1
    • /
    • 2016
  • The Sagittarius-Carina spiral arm in the Galaxy contains several massive young open clusters. We present a deep optical photometric study on the massive young open clusters in the Sagittarius-Carina arm, Westerlund 2 and the young open clusters in the ${\eta}$ Carina nebula. Westerlund 2 is a less studied starburst-type cluster in the Galaxy. An abnormal reddening law for the intracluster medium of the young starburst-type cluster Westerlund 2 is determined to be $R_{V,cl}=4.14{\pm}0.08$. The distance modulus is determined from zero-age main-sequence fitting to the reddening-corrected color-magnitude diagrams of the early-type members to be $V_0-M_V=13.9{\pm}0.14mag$. The pre-main sequence (PMS) members of Westerlund 2 are selected by identifying the optical counterparts of X-ray emission sources from the Chandra X-ray observation and mid-infrared emission sources from the Spitzer/IRAC (the Infrared Array Camera) observation. The initial mass function (IMF) shows a slightly flat slope of ${\Gamma}=-1.1{\pm}0.1$ down to $5M_{\odot}$. The age of Westerlund 2 is estimated to be. 1.5 Myr from the main-sequence turn-on luminosity and the age distribution of PMS stars. The ${\eta}$ Carina nebula is the best laboratory for the investigation of the Galactic massive stars and low-mass star formation under the influence of numerous massive stars. We have performed deep wide-field CCD photometry of stars in the ${\eta}$ Carina nebula to determine the reddening law, distance, and the IMF of the clusters in the nebula. We present VRI and $H{\alpha}$ photometry of 130,571 stars from the images obtained with the 4m telescope at Cerro Tololo Inter-American Observatory (CTIO). RV,cl in the η Carina nebula gradually decreases from the southern part (~4.5, around Trumpler 14 and Trumpler 16) to the northern part around Trumpler 15 (~3.5). Distance to the young open clusters in the ${\eta}$ Carina nebula is partly revised based on the zero-age main-sequence fitting to the reddening-corrected color-magnitude diagrams (CMDs) and the (semi-) reddening-independent CMDs. We select the PMS members and candidates by identifying the optical counterparts of X-ray sources from the Chandra Carina Complex Survey and mid-infrared excess emission stars from the Spitzer Vela-Carina survey. From the evolutionary stage of massive stars and PMS stars, we obtain that the northern young open cluster Trumpler 15 is distinctively older than the southern young open clusters, Trumpler 14 (${\leq}2.5 Myr$) and Trumpler 16 (2.5-3.5 Myr). The slopes of the IMF of Trumpler 14, Trumpler 15, and Trumpler 16 are determined to be $-1.2{\pm}0.1$, $-1.5{\pm}0.3$, and $-1.1{\pm}0.1$, respectively. Based on the RV,cl of several young open clusters determined in this work and the previous studies of our group, We suggest that higher RV,cl values are commonly found for very young open clusters with the age of < 4 Myr. We also confirm the correlation between the slope of the IMF and the surface mass density of massive stars.

  • PDF

국내산 고구마의 품종 및 조리방법별 비타민 C 함량 (Vitamin C Quantification of Korean Sweet Potatoes by Cultivar and Cooking Method)

  • 황인국;변재윤;김경미;정미남;유선미
    • 한국식품영양과학회지
    • /
    • 제43권6호
    • /
    • pp.955-961
    • /
    • 2014
  • 본 연구에서는 비타민 C 분석법을 검증하고 국내산 고구마 22품종과 조리방법에 따른 고구마의 비타민 C 함량을 분석하였다. 비타민 C 분석법을 검증하기 위해 직선성, 검출한계, 정량한계, 정밀성 및 정확성을 확인하였다. 그 결과 직선성의 상관계수 값이 0.9999이었으며, 검출한계는 $0.03{\mu}g/mL$, 정량한계는 $0.10{\mu}g/mL$, 정밀성의 상대표준편차는 5%이하, 정확성인 회수율은 95% 이상으로 우수하였다. 고구마 품종별 AA, DHA 및 TA 함량은 각각 37.76(신율미)~89.25(주황미), 23.37(신자미)~63.94(신율미) 및 68.52(신자미)~115.95(주황미) mg/100 g 범위로 품종에 따라 큰 차이를 보였다. 고구마의 평균 AA, DHA 및 TA 함량은 각각 $56.98{\pm}12.53$, $36.46{\pm}9.03$$93.44{\pm}12.00mg/100g$이었으며, 대부분 품종의 AA 함량은 40~70 mg/100 g 범위에, DHA 함량은 20~40 mg/100 g 범위에, TA 함량은 70~90 mg/100 g 범위에 존재하였다. 그리고 육질색 종류에 따른 평균TA 함량은 일반고구마와 주황색고구마가 자색고구마에 비해 유의적으로 높은 것으로 나타났다. Steaming, baking 및 frying 처리에 따른 AA, DHA 및 TA 함량은 조리 처리 후 10.61~58.41, 2.57~52.81 및 14.54~49.92% 범위로 유의적으로 감소하였고, baking 처리가 steaming 및 frying 처리에 비해 함량 감소량이 큰 것으로 나타났다. 고구마의 비타민 C 함량은 품종 및 조리방법에 따라 변이가 큰 것으로 나타났으며, 추후 연구의 기초자료로 활용이 가능할 것으로 기대된다.