Shielding Effectiveness of Magnetite Heavy Concrete on Cobalt-60 Gamma-rays

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.65-75
    • /
    • 1971
  • The gamma-ray shielding effects of magnetite concretes have been measured using a broad beam Co-60 gamma-ray source. Mathematical formulae for a trans-mission ratio-to-shield thickness relation were derived from the attenuation curve obtained experimentally and are I (x) = I (ο) exp(-$\mu$X) exp(1.03$\times$10$^{-1}$ X-3.38$\times$10$^{-3}$ X$^2$+5.29$\times$10$^{-5}$ X$^3$) when X< 20 cm, I (x) =I (ο) exp(-$\mu$X) exp(4.66$\times$10$^{-2}$ X+2.12$\times$10$^{-1}$ ) when X>20 cm. Here I (x) is radiation intensity after passing through a thickness X of absorber, I(o) is the initial radiation intensity, $\mu$ is the linear attenuation coefficient of magnetite concrete and is given by (0.0532$\rho$+ 0.0083)$^{4)}$ $cm^{-1}$ / in accordance with an earlier study, and X is the thickness of absorber. In addition, a model shield which is a rectangular magnetite concrete box with walls of 8cm thickness walls and internal demensions of 40$\times$40$\times$40 cm was constructed and its shielding effect has been measured. The emergent radiation flux appears to be greater with this configuration than with a slab shield of equal thickness.

  • PDF

A Study of the Development for Fatty Liver Quantification Diagnostic Technology from Ultrasound Images using a Simulated Fatty Liver Phantom (모사 지방간 팬텀을 활용한 초음파영상에서 지방간 정량화 진단 기술 개발을 위한 연구)

  • Yei-Ji Lim;Seung-Man Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.135-144
    • /
    • 2024
  • Ultrasonography examination has limitations in quantifying hepatic fat quantification. Therefore, this study aimed to experimentally demonstrate whether changes in signal attenuation during ultrasound imaging can be quantified using simulated hepatic phantoms to assess hepatic fat content. Additionally, we aimed to evaluate the potential of ultrasound imaging for diagnosing hepatic fatty liver by analyzing the relationship between hepatic fat content and signal intensity in ultrasound images. In this study, we developed a total of five stimulated hepatic phantoms by homogeneously mixing water and oil. We confirmed the fat content of the phantoms using magnetic resonance imaging (MRI) and ultrasound imaging, and measured signal intensity according to distance in ultrasound images to analyze the correlation and mean comparison between fat content and signal intensity. We observed that as the fat content increased, the ultrasound penetration intensity decreased, confirming the potential for quantifying hepatic fat content using ultrasound. Additionally, the analysis of the correlation between the measured fat content using MRI and the signal intensity measured in ultrasound images showed a high correlation. Statistical analysis in our study confirmed that as the fat content increased, the slope representing signal during ultrasound imaging (US-GRE) decreased. In this study, it was statistically confirmed that the US-GRE value of ultrasound images gradually decreases as the fat content increases, and it is believed that US-GRE can serve as a biomarker expressing fatty liver content.

Change of PET Image According to CT Exposure Conditions (CT 촬영 조건에 따른 PET 영상의 변화)

  • Park, Jae-Yoon;Kim, Jung-hoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.473-479
    • /
    • 2019
  • PET-CT improves performance and reduces the time by combining PET and CT of spatial resolution, and uses CT scan for attenuation correction. This study analyzed PET image evaluation. The condition of the tube voltage and current of CT will be changed using. Uniformity phantom and resolution phantom were injected with 37 MBq $^{18}F$ (fluorine ; 511 keV, half life - 109.7 min), respectively. PET-CT (Biograph, siemens, US) was used to perform emission scan (30 min) and penetration scan. And then the collected image data were reconstructed in OSEM-3D. The same ROI was set on the image data with a analyzer (Vinci 2.54, Germany) and profile was used to analyze and compare spatial resolution and image quality through FWHM and SI. Analyzing profile with pre-defined ROI in each phantom, PET image was not influenced by the change of tube voltage or exposure dose. However, CT image was influenced by tube voltage, but not by exposure dose. When tube voltage was fixed and exposure dose changed, exposure dose changed too, increasing dose value. When exposure dose was fixed at 150 mA and tube voltage was varied, the result was 10.56, 24.6 and 35.61 mGy in each variables (in resolution phantom). In this study, attenuation image showed no significant difference when exposure dose was changed. However, when exposure dose increased, the amount of dose that patient absorbed increased too, which indicates that CT exposure dose should be decreased to minimum to lower the exposure dose that patient absorbs. Therefore future study needs to discuss the conditions that could minimize exposure dose that gets absorbed by patient during PET-CT scan.

Radiation Shielding to Minimize Image Information Loss (영상 정보 손실을 최소화하는 방사선 차폐체 연구)

  • Su-han Jang;Sang-Hyeun Park;Myeong-Sik Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.449-457
    • /
    • 2023
  • Shielding for reducing exposure dose can make the diagnosis limited. The purpose of this study is to increase the efficiency of radiation protection and minimize the loss of image information by producing the shielding made of the water and the contrast medium which has different proportion and finding out the ideal proportion of them. Each shielding materials were made of water and water-soluble iodine contrast medium with the different proportion. The attenuation rate of absorbed dose was evaluated by the shielding materials in the plastic contents for measuring the efficiency of the radiation protection. As a result, the higher ratio of the contrast medium, the more efficient it is for radiation attenuation. The anatomical structure was observed most properly in case of the solution with 20 ml of the contrast medium and most difficultly in case of more than 60 ml of the contrast medium. In case of the signal intensity between skeleton and gas, the difference of average value had a significant as p < 0.001. Shielding with contrast medium attenuates less than the conventional shielding but in the examination for the sensitive part to radiation, it can be used to minimize the loss of the image information and reduce the exposure dose.

Experimental Investigation of Horizontal Buoyant Discharges from a Rosette-type Riser Using LIF System

  • Kwon, Seok Jae;Seo, Il Won;Kim, Ho Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.463-467
    • /
    • 2004
  • Rosette-type diffusers with four-ports per riser are constructed in relatively shallow water in Korea. However, the trajectorial bending phenomena due to lower-pressure inside the surrounded buoyant jets on the riser was not considered in most models and was not observed without any experimental results. The buoyant jet behavior affected by the bending effect where there have been growing interests need to be verified experimentally and need to be preceded in the analysis of the characteristics of the buoyant jets oil a riser. The hydraulic model experiments have been carried out to investigate the characteristics of the behavior of horizontal buoyant jets discharged from a Rosette-type riser with four ports as well as single port over a certain range of the experimental conditions including initial momentum and initial buoyancy using LIF (Laser Induced Fluorescence) system to obtain concentration fields. The intensity of the fluorescent light in each pixel on the images obtained from LIF system with the tracer of Rhodamine H was converted to the local dye concentration with a set of calibration procedures to account for the non-uniform distribution of light intensity and the attenuation of light energy by water medium. The experimental results shows that the trajectories from Your ports tend to bend more and more to the inner side with the increase of the densimetric Froude number while the buoyant jet from a single port rises up without any bending phenomena. The previous models, VISJET and Seo et al. (2002), do not simulate the trajectories well except the region before the bending section. This study will focus on the analysis of the behavior of the buoyant jets for mainly a Rosette-type riser by conducting hydraulic model experiments using LIF system.

  • PDF

Design of the Satellite Beacon Receiver Using Array Based Digital Filter (다중배열 디지털필터를 이용한 위성비콘 수신기 설계)

  • Lee, Kyung-Soon;Koo, Kyung-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.10
    • /
    • pp.909-916
    • /
    • 2016
  • The beacon receiver is an equipment which detects and measures the signal strength of transmitting satellite beacon signal. Beacon signals transmitted by satellites are low power continuous wave(CW) signals without any modulation intended for antenna steering to satellite direction and power control purposes on the earth. The beacon signal detection method using a very narrow band analog filter and RSSI(Received Signal Strength Intensity) has been typically used. However, it requires the implementation to track the frequency at the beacon receiver, thus a beacon frequency variation of the satellite due to temperature changes and long-term operation. Therefore, in this paper, the beacon signal detection receiver is designed by using a very narrow band digital filter array for a faster acquisition and SNR(Signal to Noise Ratio) method detection. For this purpose, by calculating the satellite link budget with the rain attenuation between satellite and ground station, and then extracting the received $C/N_o$ of the beacon signal, this work derives the bandwidth and the array number of the configured digital filter that gives the required C/N.

Seismic Fragility Assessment for Korean High-Rise Non-Seismic RC Shear Wall Apartment Buildings (국내 고층 비내진 철근콘크리트 벽식 아파트의 지진취약도 평가)

  • Jeon, Seong-Ha;Shin, Dong-Hyun;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.6
    • /
    • pp.293-303
    • /
    • 2020
  • Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.

Experimental investigation of effective atomic numbers for some binary alloys

  • Sharma, Renu;Sharma, J.K.;Kaur, Taranjot;Singh, Tejbir;Sharma, Jeewan;Singh, Parjit S.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1571-1574
    • /
    • 2017
  • In the present work, the gamma ray backscattering technique was used to determine the effective atomic numbers for certain binary alloys. With the help of a muffle furnace, the binary alloys were synthesized using the melt quenching technique with different compositions of $_{82}Pb$, $_{50}Sn$, and $_{30}Zn$. The intensity distribution of backscattered photons from radioactive isotope $^{22}Na$ (511 keV) was recorded with the help of GAMMARAD5 [$76mm{\times}76mm$ NaI(Tl) scintillator detector] and analyzed as a function of both atomic number and thickness of the target material. The effective atomic numbers for the same binary alloys were also computed theoretically using the atomic to electronic cross-section method with the help of the mass attenuation coefficient database of WinXCom (2001). Good agreement was observed between theoretical and experimental results for the effective atomic numbers of all the selected alloys.

Analysis of Sound Attenuation by Chambers in Duct Systems by the Finite Element Method (유한요소법에 의한 소음기의 감음특성해석)

  • 최석주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.23-27
    • /
    • 1991
  • 각종 홀 (음악홀, 극장, 사무실건물)의 공조 덕트계에는 미로형소음챔버가 설 치되는 경우가 많다. 이러한 소음장치를 건물내부에 설치하는 경우에는 건물 설계단계에서부터 소음챔버로 인한 감음양(투과손실 : Transmission Loss)의 예측계산이 중요하다. 그렇지만, 일반적인 소음장치는 그 형상이나 내표면의 흡음조건이 아주 복잡하기 때문에, 현단계에서는 간단한 이론만으로 투과손 실예측이 거의 불가능하다. 지금까지 이 문제에 대해서 유한요소법(Finite Element Method : FEM)을 이용해 검토한 예가 종종 소개되었으나, 대부분 소음챔버의 입구와 출구에서의 임의의 점에 대한 음압비를 투과손실로서 구 하고 있다. 그러나, 소음기자체의 실질적인 투과손실특성을 알기 위해서는 소음기의 입력 파워에 대한 출력파워의 비로서 구하지 않으면 안된다. 따라 서, 본 연구에서는 유한요소법에 의한 복소음향인텐시티(Complex sound intensity)의 수치계산법을 각종소음기 (팽창형, 미로형)의 투과손실해석에 적 용하기 위하여 이론적인 면에서 고찰했으며, 프로그램도 개발하여 모델해석 에 적용하였다. 또한, 위에서 언급된 수치해석법의 타당성의 검증을 위하여, 측정에 의한 투과손실예측방법으로서 크로스스펙트럼(Cross Spectrum)법에 의한 음향인텐시티계측법의 이용에 대해서 이론적으로 고찰했으며, 그 이론 을 기초로 한 축척 모형실험을 병행하였다.

  • PDF

Impedance Characteristics of an Expansion-Resonator Type Pulsation Attenuator(Attenuation on Flow and Pressure Ripple form a Hydraulic Piston Pump) (팽창 공명기형 맥동 감쇠기의 임피던스 특성(유압용 피스톤 펌프의 유량.압력맥동 감쇠))

  • 이상기
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.1
    • /
    • pp.88-95
    • /
    • 2000
  • In this paper, an expansion-resonator type pulsation attenuator is proposed to absorb and attenuate flow an pressure ripple with high frequencies generated from hydraulic control systems. The basic principle of a pulsation attenuator proposed here is applied to propagation, reflection, absorption of pressure waves at the cross section of discontinuity and resonance in the pipeline. It has advantage of the compact size and high degree fo freedom for installation in hydraulic systems. The design scheme based on distributed parameter pipeline system with dissipative viscous compressible model is developed. To investigate the reduction of flow and pressure ripple with high frequencies produced by swash plate type axial piston pump, two kinds of attenuators are manufactured. It is experimently confirmed that the spectral intensity of flow and pressure ripple with high frequencies from the pump are reduced up to about 20$^{\circ}$~30dB by using attenuators proposed here. The calculated results were in good agreement with the measured values. From there sults of this study, it is shown that an expansion-resonator type pulsation attenuator is effective in a wide frequency ranges to attenuate the flow and pressure ripple from hydraulic components.

  • PDF