• Title/Summary/Keyword: integrity evaluation instrument

Search Result 3, Processing Time 0.018 seconds

Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device (전원용 SPD의 건전성 평가 장치 개발)

  • Chang, Sughun;Kim, Youngjin;Kim, Sungju;Kim, Jaehyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

Evaluation of Promotional Internet Health Information about Health Functional Foods (주요 건강기능식품 관련 홍보용 인터넷 건강 정보에 대한 평가)

  • Choi, Ji Young;Lee, Jin-Seok
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.2
    • /
    • pp.65-78
    • /
    • 2014
  • Objectives: The aim of this study is to evaluate promotional Internet health information on health functional foods with regard to labeling information, website structure, and overall quality. Methods : The websites of 15 producers of three health functional foods (Red ginseng, vitamin, aloe) were selected. Ministry of Food and Drug Safety (MFDS) required labeling information was used to evaluate the integrity of basic information, and the structural properties of the websites were investigated. Moreover, DISCERN instrument was used to evaluate reliability and quality of information. Results : 1) Among MFDS required labeling information, seven items, including 'sell by date', and 'possible side effects' were not fully specified, and only 6.7% of Internet advertisements provided 'possible side effects'. 2) Each of 92.9% of these websites offered 'Introducation to websites and producers', and 'customer service', whereas only 64.3% and 42.9% of these websites offered 'FAQ about website utilization' and 'multilingual support', respectively. 3) The evaluation using DISCERN instrument showed the scores of $2.03{\pm}0.24$ in reliability, $1.87{\pm}0.28$ in quality, and $2.10{\pm}0.55$ in overall quality. Conclusions : Current promotional Internet health information on health functional foods has various weaknesses in terms of reliability and quality that need to be improved.

A Study on Suppression of UT Grain Noise Using SSP MPO Algorithms (SSP MPO 알고리즘을 이용한 초음파 결정립 잡음 억제에 관한 연구)

  • Koo, Kil-Mo;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.6
    • /
    • pp.81-89
    • /
    • 1996
  • It is very important for ultrasonic test method to evaluate the integrity of the class I components in nuclear power plants. However, as the rltrasonic test is affected by internal structures and configurations of test materials, backscattering, that is, time invariant noise is generated in large grain size materials. Due to the above reason, the received signal results in low signal to noise(S/N) ratio. Split spectrum processing(SSP) technique is effective to suppress the grain noise. The conventional SSP technique. however, has been applied to unique algorithm. This paper shows that MPO(minimization and polarity threshold) algorithm which two algorithms are applied simulatancously, was utilized, the signal processing time was shorten by using the new constant-Q SSP with the FIR filter which frequency to bandwidth ratio is constant and the optimum parameters were analysed for the signal processing to longitudinal wave and shear wave with the same requirements of inspection on nuclear power plant site. Moreover, the new ultrasonic test instrument, the reference block of the same product form and material specification, stainless stell test specimens and copper test specimens block of the same fabricated for the application of new SSP technique. As the result of experimental test with new ultrasonic test instrument and test specimens, the signal to noise ratio was improved by appying the new SSP technique.

  • PDF