• 제목/요약/키워드: integrity assessment

검색결과 552건 처리시간 0.034초

구강점막의 통합성 사정기록 체계화를 위한 최소자료세트(Minimum Data Set) 규명 (Identifying Minimum Data Sets of Oral Mucous Integrity Assessment for Documentation Systematization)

  • 김명수;정현경;강명자;박남정;김현희;류정미
    • 중환자간호학회지
    • /
    • 제12권1호
    • /
    • pp.46-56
    • /
    • 2019
  • Purpose : The purpose of this study was to identify minimum data sets for oral mucous integrity-related documentation and to analyze nursing records for oral care. Methods: To identify minimum data sets for oral status, the authors reviewed 26 assessment tools and a practical guideline for oral care. The content validity of the minimum data sets was assessed by three nurse specialists. To map the minimum data sets to nursing records, the authors examined 107 nursing records derived from 44 patients who received chemotherapy or hematopoietic stem cell transplantation in one tertiary hospital. Results: The minimum data sets were 10 elements such as location, mucositis grade, pain, hygiene, dysphagia, exudate, inflammation, difficulty speaking, and moisture. Inflammation contained two value sets: type and color. Mucositis grade, pain, dysphagia and inflammation were recorded well, accounting for a complete mapping rate of 100%. Hygiene (100%) was incompletely mapped, and there were no records for exudate (83.2%), difficulty speaking (99.1%), or moisture (88.8%). Conclusion: This study found that nursing records on oral mucous integrity were not sufficient and could be improved by adopting minimum data sets as identified in this study.

Development of a Quality Assurance Safety Assessment Database for Near Surface Radioactive Waste Disposal

  • Park J.W.;Kim C.L.;Park J.B.;Lee E.Y.;Lee Y.M.;Kang C.H.;Zhou W.;Kozak M.W.
    • Nuclear Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.556-565
    • /
    • 2003
  • A quality assurance safety assessment database, called QUARK (QUality Assurance Program for Radioactive Waste Management in Korea), has been developed to manage both analysis information and parameter database for safety assessment of low- and intermediate-level radioactive waste (LILW) disposal facility in Korea. QUARK is such a tool that serves QA purposes for managing safety assessment information properly and securely. In QUARK, the information is organized and linked to maximize the integrity of information and traceability. QUARK provides guidance to conduct safety assessment analysis, from scenario generation to result analysis, and provides a window to inspect and trace previous safety assessment analysis and parameter values. QUARK also provides default database for safety assessment staff who construct input data files using SAGE(Safety Assessment Groundwater Evaluation), a safety assessment computer code.

적합성 평가 활동의 최근 동향 (Recent Trends of Conformity Assessment Activity)

  • 양보석
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.459-464
    • /
    • 2002
  • In this paper, the recent trends of conformity assessment activity which is carrying out at ISO is summarized. It is an increasing requirement of quality assurance systems that a company's engineers and technicians are able to demonstrate that they have the required level of knowledge and skill. This is particularly so since maintenance and Inspection activities are very operator dependent and those in authority have to place great reliance on the skill, experience, Judgement and integrity of the personnel involved.

  • PDF

원전 기기 내부구조물에 대한 구조건전성평가 (Structural Integrity Assessment of the Internal Structure)

  • 이한희;최진용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3497-3500
    • /
    • 2007
  • The internal structure is subjected to dynamic analysis due to the structural integrity. The internal structure shall be installed in the vertical hole call IR1 of reactor core. In order to verify the deflection of the internal structure, the mode and response spectrum analysis of the internal structure was performed. The natural frequency of the internal structure is 11.6 Hz(mode 1 and 2) and deflections of the internal structure are less than values of allowable design (3.2 mm).

  • PDF

원자로냉각재펌프 맥동에 대한 APR1400 원자로내부구조물의 진동 및 응력 해석 (Vibration and Stress Analysis for Reactor Vessel Internals of Advanced Power Reactor 1400 by Pulsation of Reactor Coolant Pump)

  • 김규형;고도영;김성환
    • 한국소음진동공학회논문집
    • /
    • 제21권12호
    • /
    • pp.1098-1103
    • /
    • 2011
  • The structural integrity of APR1400 reactor vessel internals has been being assessed referring the US Nuclear Regulatory Commission regulatory guide 1.20, comprehensive vibration assessment program. The program is composed of a vibration and stress analysis, a vibration and stress measurement, and an inspection. This paper covers the vibration and stress analysis on the reactor vessel internals by the pulsation of reactor coolant pump. 3-dimensional models to calculate the hydraulic loads and structural responses were built and the pressure distributions and the structural responses were predicted using ANSYS. This paper presents that APR1400 reactor vessel internals have enough structural integrity against the pulsation of reactor coolant pump as the peak stress of the reactor vessel internals is much lower than the acceptance limit.

FMEDA 기법을 적용한 SIL 등급 판정에 관한 사례연구 (Case Study on the Assessment of SIL Using FMEDA)

  • 김병철;김영진
    • 산업공학
    • /
    • 제25권4호
    • /
    • pp.376-381
    • /
    • 2012
  • As the number, complexity and interaction of electrical, electronic and programmable electronic (E/E/PE) systems increase, a growing emphasis has been placed on the concept of functional safety during product development. IEC 61508 provides guidelines and standardized procedures in the development of reliable and dependable E/E/PE systems to assure functional safety. Determining risk classes (i.e., safety integrity levels, SILs) associated to a specific E/E/PE item may be recognized as one of the most crucial activities in the product development per IEC 61508 since SILs are used to specify necessary safety requirements for achieving an acceptable residual risk. This article presents a case study on the assessment of SILs applying failure modes, effects and diagnostic analysis (FMEDA) from which failure rates may be derived for each important failure category by combining a standard FMEA with online diagnostic techniques.

파이프라인의 건전성 평가 (The integrity assessment of the pipeline)

  • 이억섭;황인현
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2000년도 춘계 학술논문발표회 논문집
    • /
    • pp.25-30
    • /
    • 2000
  • The object of this work is to develop an assessment system for pipeline integrity The system consists of four module applications for internal algorithm; the effect of corrosion in pipeline, crack, stress corrosion crack (SCC) and fatigue modules. Presently, the module of the external corrosion has been developed and the internal algorithm for the effect of corrosion in pipeline and the database of the system are described in this paper, The database of the system is separated to mainly four parts; geometry of pipeline, material properties, boundary conditions and general Properties. Each components of the system are designed by user-friendly concept. This system may give a guideline for maintenance and modifications for the pipeline at the industrial sight. Furthermore, a procedure to evaluate an inspection interval is also provided.

  • PDF

APR1400 원자로 내부배럴집합체 상부판 구조응답해석 (Structural Response Analysis on Inner Barrel Assembly Top Plate of APR1400 Reactor Vessel)

  • 김규형;고도영;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.907-910
    • /
    • 2012
  • Since the inner barrel assembly of the Advanced Power Reactor 1400 reactor vessel is a new design feature introduced instead of CEA(control element assembly) shroud assembly, the inner barrel assembly can be a significant object of structural integrity assessment. This paper covers the structural responses of top plate, which is a component of the inner barrel assembly, against the deterministic hydraulic load induced by pump pulsation and the random hydraulic load induced by turbulence of coolant. The top plate responds to the deterministic hydraulic load more than to the random hydraulic load and shows enough structural integrity. The results of this paper will be important basis for the selection of instruments and measurement location.

  • PDF

Effect of External Corrosion in Pipeline on Failure Prediction

  • Lee, Ouk-Sub;Kim, Ho-Jung
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권2호
    • /
    • pp.48-54
    • /
    • 2000
  • This paper presents the effect of shape of external corrosion in pipeline on failure prediction by using a numerical simulation. The numerical study for the pipeline failure analysis is based on the FEM(Finite Element Method)with an elastic-plstic and large-deformation analysis. Corrosion pits and narrow corrosion grooves in pressurized pipeline were analysed. A failure criterion, based on the local stress state at the corrosion and a plastic collapse failure mechanism, is proposed. The predicted failure stress assessed for the simulated corrosion defects having different corroded shapes along the pipeline axis compared with those by methods specified in ANSI/ASME B31G code and a modified B31G code. It is concluded the corrosion geometry significantly affects the failure behavior of corroded pipeline and categorisation of pipeline corrosion should be considered in the development of new guidance for integrity assessment.

  • PDF

구체손상에 따른 콘크리트 교각의 고유진동수 변화 (Damage Effects on the Natural Frequency of Concrete Pier)

  • 박병철;오금호;박승범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.335-338
    • /
    • 2005
  • This study was performed to verify that the impact vibration test on the damaged concrete pier can be adopted for assessment of the bridge substructure integrity. Using the experimental modal analysis, the dynamic property changes of the concrete pier are investigated according to the damage levels which are modeled by the loss of cross section area of the pier body. As a result of the impact vibration test, it is found that the natural frequency of the bridge substructure is reduced due to the damage on the pier such as loss of cross section area, and the natural frequency can be used for assessment of the integrity index.

  • PDF