• Title/Summary/Keyword: integrity assessment

Search Result 552, Processing Time 0.027 seconds

Diagnosis of Sapkyo Stream Watershed Using the Approach of Integrative Star-Plot Area (생태평가모형(Integrative Star-Plot Area)을 이용한 삽교천 수계 진단)

  • Kim, Ja-Hyun;Yeom, Dong-Hyuk;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.3
    • /
    • pp.356-368
    • /
    • 2010
  • In this study, we applied approach of integrative star-plot area (SPA), chemical water quality and habitat conditions (QHEI) to diagnoze ecological conditions at the eight sampling sites of Sapkyo Stream. These outcomes were compared with biological health based on the Index of Biological Integrity (IBI) using fish assemblage. And then, we evaluated the integrative ecological health condition using the star-plot method. This approach based on the sum of all the star-plot areas over these water and habitat characteristics. It was developed to reflect an integrative assessment of the ecological health in the stream. The biological health, based on the model values of IBI indicating "fair-poor" condition according to the criteria. Physical habitat health, based on the QHEI, averaged 123 indicating a "good-fair" condition. Also, chemical health, based on simply BOD values indicating "poor grade" according to the criteria of the Ministry of Environment Korea (MEK). The SPA indicating that 50% of the all was impaired condition and the most sampling sites were downstream sites influenced by the point and non-point sources. Overall our results suggest that the ecological health impact was a combined effect of eutrophication and habitat degradations in the stream. The approach of SPA can be used as a tool to evaluate the integrative health of stream environment and to identify possible causes of observed effects.

Assessment of the Potential Carbon Credits from Reducing Emissions from Deforestation and Enhancement of Forest Carbon Stock Activities in Developing Countries (개도국의 산림전용으로 인한 온실가스 배출량 감축 및 산림탄소축적 증진 활동의 탄소배출권 잠재력 평가)

  • Bae, Jae Soo;Bae, Ki Kang
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.263-271
    • /
    • 2009
  • This study aims to identify negotiation alternatives related to Post-2012 reducing emissions from deforestation (RED) and enhancement of forest carbon stock (EFCS) activities. It also aims to recommend a negotiation strategy considering environmental integrity and national interest on the basis of estimating reduction potentials of each alternative on the assumption that tradable carbon credits play an important role as positive incentives. In order to estimate greenhouse gas (GHG) reduction potentials and income potential from RED and EFCS activities, 99 countries were selected by the Global Forest Resources Assessment of the Food and Agriculture Organization of the United Nations. A 'baseline and credit' method was applied to estimate RED activities. Gross-net and net-net methods were applied for EFCS activities. According to the results, Brazil, Indonesia, and the Democratic Republic of Congo have more potential to get positive incentives through RED, while China, Chile, and the Republic of Korea have more potential to get positive incentives through EFCS. This study suggests including both RED and EFCS activities in the boundary of policy approaches and endowment of positive incentives to consider GHG reduction potentials in the global scale and equity among developing countries. Making a discount rate application of forest management activities can be also recommended to factor out the effects of human-induced activities by EFCS activities.

Development of a Short-term Failure Assessment of High Density Polyethylene Pipe Welds - Application of the Limit Load Analysis - (고밀도 폴리에틸렌 융착부에 대한 단기간 파손 평가법 개발 - 한계하중 적용 -)

  • Ryu, Ho-Wan;Han, Jae-Jun;Kim, Yun-Jae;Kim, Jong-Sung;Kim, Jeong-Hyeon;Jang, Chang-Heui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.405-413
    • /
    • 2015
  • In the US, the number of cases of subterranean water contamination from tritium leaking through a damaged buried nuclear power plant pipe continues to increase, and the degradation of the buried metal piping is emerging as a major issue. A pipe blocked from corrosion and/or degradation can lead to loss of cooling capacity in safety-related piping resulting in critical issues related to the safety and integrity of nuclear power plant operation. The ASME Boiler and Pressure Vessel Codes Committee (BPVC) has recently approved Code Case N-755 that describes the requirements for the use of polyethylene (PE) pipe for the construction of Section III, Division 1 Class 3 buried piping systems for service water applications in nuclear power plants. This paper contains tensile and slow crack growth (SCG) test results for high-density polyethylene (HDPE) pipe welds under the environmental conditions of a nuclear power plant. Based on these tests, the fracture surface of the PENT specimen was analyzed, and the fracture mechanisms of each fracture area were determined. Finally, by using 3D finite element analysis, limit loads of HDPE related to premature failure were verified.

A numerical study on the fatigue evaluation of mark-III LNG primary barrier (수치해석을 이용한 Mark-III LNG 1차 방벽에 대한 피로 평가)

  • Kwon, Sun-Beom;Kim, Myung-Sung;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.337-344
    • /
    • 2017
  • The demand of liquified natural gas is increasing due to environmental issues. This reason has resulted in increasing the capacity of liquified natural gas cargo tank. The Mark-III type primary barrier directly contacts liquified natural gas. Also, the primary barrier is under various loading conditions such as weight of liquified natural gas and sloshing loads. During a ship operation, various loads can cause fatigue failure. Therefore, the fatigue life prediction should be evaluated to prevent leakage of liquified natural gas. In the present study, the fatigue analysis of insulation system including primary barrier is performed using a finite element model. The fatigue life of primary barrier is carried out using a numerical study. The value of principle stress and the location of maximum principle stress range are calculated, and the fatigue life is evaluated. In addition, the effects on the insulation panel status and the arrangement of knot or corrugation are analyzed by comparing the fatigue life of various models. The insulation system which has best structural performance of primary barrier was selected to ensure structural integrity in fatigue assessment. These results can be used as a design guideline and a fundamental study for the fatigue assessment of primary barrier.

Assessment of Ecosystem Health during the Freshwater Discharge in the Youngsan River Estuary (영산강 하구둑 담수 방류에 따른 하구 건강성 평가)

  • Lee, Dahye;Park, Gunwoo;Lee, Changhee;Shin, Yongsik
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.1
    • /
    • pp.46-56
    • /
    • 2017
  • The Youngsan River estuary was physically changed by the construction of a sea embankment at near the mouth of estuary. Weirs were also constructed recently in the freshwater zone and it was reported that algal blooms occur more frequently. The freshwater introduced into saltwater zone from sluice gates of the embankment affects water quality but it has not been addressed that how the freshwater inputs influence the health of marine ecosystem. In this study, we used the data of water properties and phytoplankton communities collected at three stations for 4 days including before the freshwater discharge, during the discharge and after 1 and 2 days of discharge events. WQI(water quality index), TRIX (trophic status index) and P-IBI(phytoplankton index of biotic integrity) were used to evaluate the ecosystem health and long-term data were also utilized to determine the criteria for P-IBI. The results showed that grades of the ecosystem health assessed by the indices were low at the station near the gates and increased as downstream. However, the temporal pattern of grades was different depending on methods. Grades of WQI and TRIX decreased during the discharge and restored after the discharge whereas the grades of P-IBI decreased slightly even after the discharge. This suggests that P-IBI is more applicable to estuarine systems where experience extreme change of water properties than WQI and TRIX since P-IBI includes phytoplankton that can respond quickly to the change.

A Study on the Development of the Repair Standards for Underground Pipelines Carrying Natural Gas (도시가스 매설배관 보수기준 개발에 관한 연구)

  • Ryou, Young-Don;Lee, Jin-Han;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.33-43
    • /
    • 2016
  • Grinding, weld deposition, type A sleeve, type B sleeve, composite sleeve, hot tapping and clamp are used as the method to repair the buried pipelines in the United States, UK and Europe. In the event of defect to the pipeline, they have repaired the pipeline through the fitness-for-service assessments. In addition, they have guidelines for the possible repair methods to apply to each type of damage, which is occurred due to the 3rd party construction or corrosion. According to the KGS FS551, Safety Validation in Detail including ECDA(External Corrosion Direct Assessment) as one method of integrity management should be carried out for the old pipeline which supply natural gas as the middle pressure in Korea. Where a defect on the pipelines is found, on the result of Safety Validation in Detail, the pipelines should be repaired or replaced by new piping. However, there are no guidelines or regulations regarding the repair and reinforcement of pipeline, so that, cutting the damaged pipeline and replacing it as a segment of new pipe is the only way in Korea until now. We have suggested pipeline repair methods including type A, B sleeve, composite sleeve, after the survey of foreign repair method and standards including the method of United States and the United Kingdom, and after analysis of the results on pipeline repair test including type A, type B sleeve and composite sleeve.

Study of Quantitative Assessment Standard for Type 1 and Type 2 Gas Cylinders Using Acoustic Emission Testing (음향방출법을 이용한 Type 1 및 Type 2 가스실린더의 정량적 평가기준에 대한 연구)

  • Kim, Dong-Hyun;Lee, Sang-Bum;Kim, Kyung-Hoon;Yoon, Dong-Jin;Bae, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Acoustic emission testing (AET) of cylinders is advantageous in that it can be directly conducted on cylinders installed in a car, without needing to dissemble them on a real-time basis. Therefore, users prefer AET over other nondestructive testing methods. Owing to these advantages of AET, it has been approved by the Department of Transportation of the U.S. as a safety evaluation method for pressure containers or as an alternative to the hydroproof testing method. This paper presents a study of the quantitative evaluation criteria for a container having ultrasonic testing defects and also for Type 1 and Type 2 gas cylinders, which are defective seamless pressure containers provided by NK, a manufacturer of pressure containers. For the Type 1 cylinder, the process from crack growth to leak was observed in a repetitive fatigue test using a 113 L container according to ASTM E 1419-02. Further, for the Type 2 cylinder, integrity was evaluated using a 119 L sound container and a container damaged by hydraulic pressure, by the slow-fill method according to ASTM E 2191-02. Based on the AET results of the Type 1 and Type 2 cylinders, quantitative evaluation criteria were established for a defective and non-defective container.

Characteristics of defect on segmental lining of TBM tunnel in operational subway (운용중인 국내 지하철 TBM터널의 세그먼트라이닝 결함특성 분석)

  • Choo, Jinho;Lee, DongHun;Noh, EunChul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.109-128
    • /
    • 2022
  • The precise inspection for safety and diagnosis (PISD) of tunnel has been conducted by the special act on safety control of public structures. However, the present assessment for the segmental lining of TBM tunnel has limitation such as: NDTs for integrity, segmental configuration for field inspection, and consideration for jacking system. Even if the number of TBM tunnel is less than 1% of enrolled facility in FMS, more attention to maintenance should be necessary due to its usage such as multi-use facility and national important facility. Compared to NATM tunnel, excavated by drilling and blasting and then installed lining by cast-in-place within 6~12 m, TBM tunnel is cut out ground by disk and cutter-bit and then assembled 7 pieces of precast segment, 1.2~1.4 m wide. Different features of design, construction, and maintenance should be considered to be more exact evaluation of TBM tunnel. The characteristics of defect is categorized and analyzed with 11 operational TBM tunnels in domestic subway. To be more comprehend various particular defects, foreign studies have been also adapted. Crack and leakage are categorized in 7 patterns. Breakage/spalling and corrosion are also grouped into 3 patterns. Patterned defects or damages are fed back in design, construction, and are useful guidelines for maintenance stage in future.

A Sanitizer for Detecting Vulnerable Code Patterns in uC/OS-II Operating System-based Firmware for Programmable Logic Controllers (PLC용 uC/OS-II 운영체제 기반 펌웨어에서 발생 가능한 취약점 패턴 탐지 새니타이저)

  • Han, Seungjae;Lee, Keonyong;You, Guenha;Cho, Seong-je
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.1
    • /
    • pp.65-79
    • /
    • 2020
  • As Programmable Logic Controllers (PLCs), popular components in industrial control systems (ICS), are incorporated with the technologies such as micro-controllers, real-time operating systems, and communication capabilities. As the latest PLCs have been connected to the Internet, they are becoming a main target of cyber threats. This paper proposes two sanitizers that improve the security of uC/OS-II based firmware for a PLC. That is, we devise BU sanitizer for detecting out-of-bounds accesses to buffers and UaF sanitizer for fixing use-after-free bugs in the firmware. They can sanitize the binary firmware image generated in a desktop PC before downloading it to the PLC. The BU sanitizer can also detect the violation of control flow integrity using both call graph and symbols of functions in the firmware image. We have implemented the proposed two sanitizers as a prototype system on a PLC running uC/OS-II and demonstrated the effectiveness of them by performing experiments as well as comparing them with the existing sanitizers. These findings can be used to detect and mitigate unintended vulnerabilities during the firmware development phase.

Introduction of Two-region Model for Simulating Long-Term Erosion of Bentonite Buffer (벤토나이트 완충재 장기 침식을 모사하기 위한 Two-region 모델 소개)

  • Jaewon Lee;Jung-Woo Kim
    • Tunnel and Underground Space
    • /
    • v.33 no.4
    • /
    • pp.228-243
    • /
    • 2023
  • Bentonite is widely recognized and utilized as a buffer material in high-level radioactive waste repositories, mainly due to its favorable characteristics such as swelling capability and low permeability. Bentonite buffers play an important role in ensuring the safe disposal of radioactive waste by providing a low permeability barrier and effectively preventing the migration of radionuclides into the surrounding rock. However, the long-term performance of bentonite buffers still remains a subject of ongoing research, and one of the main concerns is the erosion of the buffer induced by swelling and groundwater flow. The erosion of the bentonite buffer can significantly impact repository safety by compromising the integrity of buffer and leading to the formation of colloids that may facilitate the transport of radionuclides through groundwater, consequently elevating the risk of radionuclide migration. Therefore, it is very important to numerically quantify the erosion of bentonite buffer to evaluate the long-term performance of bentonite buffer, which is crucial for the safety assessment of high-level radioactive waste disposal. In this technical note, Two-region model is introduced, a proposed model to simulate the erosion behavior of bentonite based on a dynamic bentonite diffusion model, and quantitative evaluation is conducted for the bentonite buffer erosion with this model.