• Title/Summary/Keyword: integrity assessment

Search Result 552, Processing Time 0.025 seconds

An Analysis of Agricultural Landuse Suitability Using Landuse Limitation Factors - A Case Study of Ibang-myeon, Changnyeong-gun, Kyungsangnam-do - (토지이용 제한인자를 활용한 농업적 토지이용 적합성 분석 - 경상남도 창녕군 이방면을 대상으로 -)

  • Jang, Gab-Sue;Park, In-Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.6
    • /
    • pp.357-372
    • /
    • 2006
  • The excessive land activities in farming can cause soil erosion, inundation by a flood, and fallow. So far land evaluation has been analyzed using the land use limitation derived from the excessive land activities. This study was done for evaluating the agricultural fields by using 3 land use limitations, inundation potential, soil erodibility potential, and fallow potential. The study area is Ibang-myeon, Changnyeong-gun, Gyeongnam-province, Korea. A logistic regression model was applied to recognize the inundation potential by a flood in the Nakdong river basin. And potential soil erodibility index (PSEI) was derived from USLE model to analyze the soil erodibility potential. And a probability model from a logistic regression model was applied to detect the fallow potential. Therefore, we found 220.7ha for the 4th grade and 86.1ha for the 5th grade was analyzed as water damage potential. Large area near Nakdong river have problem to grow the rice due to the damage by water inundation. And 213.6ha for the 3rd grade and 103.3ha for 4th grade was detected as a result of the analysis of soil erosion potential. The soil erosion potential was high when within-field integrity of soil was not stable, or the kinetic energy was high or the slope length was long due to a steep slope of a specific land. And 869.1ha for 3rd grade, 174.9ha for 4th grade, and 110.6ha for 5th grade was detected to be distributed having the fallow potential. Especially, a village, having a steep mountain, had 249.5ha for the 3rd grade, which was 28.7% of total area showing the 3rd grade. Finally, Three villages, including An-ri, Geonam-ri, Songgok-ri, showed they had largest area of the suitable land in the study area. These villages had similar topographic condition where they were far from Nakdong river, and they had relatively higher elevation and flat lands.

Evaluation of Fracture Toughness and Constraint Effect of Cruciform Specimen under Biaxial Loading (이축하중을 받는 십자형 시편의 파괴인성 및 구속효과 평가)

  • Kim, Jong Min;Kim, Min Chul;Lee, Bong Sang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.62-69
    • /
    • 2016
  • Current guidance considers that uniaxially loaded specimen with a deep crack is used for the determination of the ductile-to-brittle transition temperature. However, reactor pressure vessel is under biaxial loading in real and the existence of deep crack is not probable through periodic in-service-inspection. The elastic stress intensity factor and the elastic-plastic J-integral which were used for crack-tip stress field and fracture mechanics assessment parameters. The difference of the loading condition and crack geometry can significantly influence on these parameters. Thus, a constraint effect caused by differences between standard specimens and a real structure can over/underestimate the fracture toughness, and it affects the results of the structural integrity assessment, consequentially. The present paper investigates the constraint effects by evaluating the master curve $T_0$ reference temperature of PCVN (Pre-cracked Charpy V-Notch) and small scale cruciform specimens which was designed to simulate biaxial loading condition with shallow crack through the fracture toughness tests and 3-dimensional elastic-plastic finite element analyses. Based on the finite element analysis results, the fracture toughness values of a small scale cruciform specimen were estimated, and the geometry-dependent factors of the cruciform specimen considered in the present study were determined. Finally, the transferability of the test results of these specimens was discussed.

Thermal-structural Analysis and Fatigue Life Evaluation of a Parallel Slide Gate Valve in Accordance with ASME B&PVC (패러럴 슬라이드 게이트밸브의 열구조해석 및 ASME B&PVC 기반 피로수명 평가)

  • Kim, Tae Ho;Choi, Jae Seung;Han, Jeong Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.2
    • /
    • pp.157-164
    • /
    • 2017
  • A parallel slide gate valve (PSGV) is located between the heat recovery steam generator (HRSG) and the steam turbine in a combined cycle power plant (CCPP). It is used to control the flow of steam and runs with repetitive operations such as startups, load changes, and shutdowns during its operation period. Therefore, it is necessary to evaluate the fatigue damage and the structural integrity under a large compressive thermal stress due to the temperature difference through the valve wall thickness during the startup operations. In this paper, the thermal-structural analysis and the fatigue life evaluation of a 16-inch PSGV, which is installed on the HP steam line, is performed according to the fatigue life assessment method described in the ASME B&PVC VIII-2; the method uses the equivalent stress from the elastic stress analysis.

Application of Multiparametric Flow Cytometry (FCM) to Enumerate the Diagnosis of Pseudomonas aeruginosa and Escherichia coli

  • Hwang, Myoung-Goo;Oh, Jung-Woo;Katayama, Hiroyuki;Ohgaki, Shinichiro;Cho, Jin-Kyu
    • Environmental Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.35-39
    • /
    • 2012
  • In this study, multiparametric flow cytometry (FCM) was installed to enumerate the diagnosis of Pseudomonas aeruginosa ATCC 10145 and Escherichia coli K12 (IFO 3301). The nucleic acids (DNA/RNA) were double stained by a LIVE/DEAD bacLight viability kit, involving green SYTO 9 and red propidium iodide (PI), based on the permeability of two chemicals according to the integrity of plasma membrane. As the results showed, the gate for dead bacteria was defined as the range of $0.2{\times}10^0$ to $6.0{\times}10^1$ photo multiplier tube (PMT) 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $2.0{\times}10^2$ PMT 4 fluorescence (Y-axis), and the gate for live bacteria was defined as the range of $6.0{\times}10^0$ to $6.0{\times}10^2$ PMT 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $4.0{\times}10^2$ PMT 4 fluorescence (Y-axis). In the comparison of the number of the tested bacteria detected by FCM (viability assessment) and plate culture (cultivability assessment), the number of bacteria detected by FCM well represented the number of bacteria that was detected by the colony forming unit (CFU) counting method when bacteria were exposed to isopropyl alcohol and silver/copper cations. Consequently, it is concluded that the application of FCM to monitor the functional effect of disinfectants on the physiological status of target bacteria can offer more rapid and reliable data than the plate culture colony counting method.

Comprehensive Vibration Assessment Program Measurement Test Plan for Advanced Power Reactor 1400 (신형경수로 1400 종합진동평가프로그램 측정시험 계획)

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.589-595
    • /
    • 2013
  • A reactor vessel internals comprehensive vibration assessment program(RVI CVAP) of an advanced power reactor 1400(APR1400) is being verified on the integrity of RVI for the design life of the plant by performing the non-prototype category-2 type on the US Nuclear Regulatory Commission Guide(NRC RG) 1.20, for which consists of a vibration and stress analysis program, a limited vibration measurement program, an inspection program, and the correlation of these programs. The aim of this paper is to describe the plan for the vibration measurement, test and acceptance criteria portion, and documentation and results of the APR1400 RVI CVAP. We will conduct the limited vibration measurement program of the APR1400 RVI CVAP according to the measurement plan and the vibration measurement testing in this paper.

  • PDF

Post Closure Long Term Safety of an Initial Container Failure Scenario for a Potential HLW Repository (고준위 방사성폐기물 처분장에서 초기 용기 파손 시나리오의 장기 방사선적 안전성 평가)

  • 황용수;서은진;이연명;강철형
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.229-232
    • /
    • 2003
  • A waste container, one of the key compartments in a multi-barrier system for a potential high level radioactive waste (HLW) repository in Korea ensures the mechanical stability against the lithostatic pressure of a deep geologic strata and the swelling pressure of the bentonite buffer. Also, it prohibits potential release of radionuclides for a certain period of time. before it is corroded by impurities. Even though the materials of a waste container is carefully chosen and all manufacturing processes are under heavy quality assurance, there might be a slight chance of intial defects in a waste container. Also, during the deposition of a waste container in a repository, there might be a chance of an incident affecting the integrity of a waste container. In this study, the FEP's and the scenarios over radiological impact of a potential initial waste container defect was developed. Then the total system performance assessment on this initial waste container failure (ICF) scenario was carried out by the MASCOT-K, one of the probabilistic safety assessment tools KAERI has developed. Results show that for the data set studied in this paper, the annual individual dose by the ICF scenario well meets the KINS regulation.

  • PDF

Validation of Computational Fluid Dynamics Calculation Using Rossendorf Coolant Mixing Model Flow Measurements in Primary Loop of Coolant in a Pressurized Water Reactor Model

  • Farkas, Istvan;Hutli, Ezddin;Farkas, Tatiana;Takacs, Antal;Guba, Attila;Toth, Ivan
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.941-951
    • /
    • 2016
  • The aim of this work is to simulate the thermohydraulic consequences of a main steam line break and to compare the obtained results with Rossendorf Coolant Mixing Model (ROCOM) 1.1 experimental results. The objective is to utilize data from steady-state mixing experiments and computational fluid dynamics (CFD) calculations to determine the flow distribution and the effect of thermal mixing phenomena in the primary loops for the improvement of normal operation conditions and structural integrity assessment of pressurized water reactors. The numerical model of ROCOM was developed using the FLUENT code. The positions of the inlet and outlet boundary conditions and the distribution of detailed velocity/turbulence parameters were determined by preliminary calculations. The temperature fields of transient calculation were averaged in time and compared with time-averaged experimental data. The perforated barrel under the core inlet homogenizes the flow, and therefore, a uniform temperature distribution is formed in the pressure vessel bottom. The calculated and measured values of lowest temperature were equal. The inlet temperature is an essential parameter for safety assessment. The calculation predicts precisely the experimental results at the core inlet central region. CFD results showed a good agreement (both qualitatively and quantitatively) with experimental results.

An Assessment of the Prestress Force on the Bonded Tendon Using the Strain and the Stress Wave Velocity (변형률과 응력파속도를 이용한 부착식 텐던의 긴장력 평가)

  • Jang, Jung Bum;Hwang, Kyeong Min;Lee, Hong Pyo;Kim, Byeong Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.183-188
    • /
    • 2012
  • The bonded tendon was adopted to the reactor containment building of some operating nuclear power plants in Korea and the assessment of the prestress force on the bonded tendon is very important for the evaluation of the structural integrity. The prestress force of the bonded tendon at real reactor containment building, was evaluated using the SI technique and impact signal analysis technique which were developed to improve the existing indirect assessmment technique. For these techniques, the strain of the reactor containment building and the stress wave velocity of the bonded tendon were measured. Both SI technique and impact signal analysis technique give the highly reliable results comparison with the existing theoretical approach. Therefore, it is confirmed that the developed techniques are very useful for the evaluation of the prestress force on the bonded tendon.

An Investigation on the Technical Background for Carbon-14 Monitoring in Radioactive Effluents (원자력시설의 Carbon-14 방사성유출물에 대한 감시배경의 조사)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae;Kim, Seok-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.195-200
    • /
    • 2009
  • effluents to the environment. The activity of carbon-14, one of the radioactive effluents, in the environment is already high level and its effect on radiation exposure to the public and the environment is insignificant; thus, NPPs did not perform the carbon-14 monitoring in effluents in the past. By the way, effluents of noble gas and particulate radioactive materials originated from nuclear fuels has been continuously reduced due to both the advancement of manufacturing and integrity technology for nuclear fuels and the improvement of operation methods of NPPs. Futhermore, the portion of dose assessment by tritium and carbon-14 to the public has been relatively increased because the lower limit of detection for low-energy beta sources, such as tritium and carbon-14, is low due to the advancement of radiation detection technology. In this paper, the technical background for carbon-14 monitoring in nuclear facilities was investigated using United States technical reports and papers. This paper also reviews whether carbon-14 monitoring is necessary or not based on the investigated documents.

Failure Probability Assessment of Natural Gas Pipeline under Combined Stresses (복합하중에 의한 천연가스 배관의 파손확률 평가)

  • Baek, Jong-Hyun;Chang, Yun-Chan;Kim, Ik-Jung;Kim, Cheol-Man;Kim, Young-Pyo
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.10-17
    • /
    • 2020
  • The structural reliability assessment can be used to improve the reliability in the asset integrity management of the pipeline by using a geometric variation, mechanical characteristics, load change and operating condition as evaluation factors. When evaluating structural reliability, the failure probability of the natural gas pipe is evaluated by the relationship of the resistance of the pipe material to external loads. The failure probability of the natural gas pipe due to the combined stresses such as the internal pressure, thermal stress and bending stress was evaluated by using COMREL program. When evaluating the failure probability of the natural gas pipe, a buried depth of 1.5 to 30 m, a wheel load of 2.5 to 20 ton, a temperature difference of 45℃, an operating pressure of 6.86MPa, and a soil density of 1.8 kN/㎥ were used. The failure probabilities of the natural gas pipe were evaluated by the Von-Mises stress criterion as the maximum allowable stress criterion under the combined stresses.