• Title/Summary/Keyword: integrated facility

Search Result 480, Processing Time 0.035 seconds

A Case Study on Product Production Process Optimization using Big Data Analysis: Focusing on the Quality Management of LCD Production (빅데이터 분석 적용을 통한 공정 최적화 사례연구: LCD 공정 품질분석을 중심으로)

  • Park, Jong Tae;Lee, Sang Kon
    • Journal of Information Technology Services
    • /
    • v.21 no.2
    • /
    • pp.97-107
    • /
    • 2022
  • Recently, interest in smart factories is increasing. Investments to improve intelligence/automation are also being made continuously in manufacturing plants. Facility automation based on sensor data collection is now essential. In addition, we are operating our factories based on data generated in all areas of production, including production management, facility operation, and quality management, and an integrated standard information system. When producing LCD polarizer products, it is most important to link trace information between data generated by individual production processes. All systems involved in production must ensure that there is no data loss and data integrity is ensured. The large-capacity data collected from individual systems is composed of key values linked to each other. A real-time quality analysis processing system based on connected integrated system data is required. In this study, large-capacity data collection, storage, integration and loss prevention methods were presented for optimization of LCD polarizer production. The identification Risk model of inspection products can be added, and the applicable product model is designed to be continuously expanded. A quality inspection and analysis system that maximizes the yield rate was designed by using the final inspection image of the product using big data technology. In the case of products that are predefined as analysable products, it is designed to be verified with the big data knn analysis model, and individual analysis results are continuously applied to the actual production site to operate in a virtuous cycle structure. Production Optimization was performed by applying it to the currently produced LCD polarizer production line.

A Study on the Framework of Integrated Vulnerability Analysis of Domestic Nuclear Facilities (국내 원자력 시설 통합 취약점 분석 프레임워크 연구)

  • Mi-Joo Shin;Seong-su Yoon;Ieck-chae Euom
    • Convergence Security Journal
    • /
    • v.22 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • Cyber attacks on national infrastructure, including large-scale power outages in Ukraine, have continued in recent years. As a result, ICS-CERT vulnerabilities have doubled compared to last year, and vulnerabilities to industrial control systems are increasing day by day. Most control system operators develop vulnerability countermeasures based on the vulnerability information sources provided by ICS-CERT in the United States. However, it is not applicable to the security of domestic control systems because it does not provide weaknesses in Korean manufacturers' products. Therefore, this study presents a vulnerability analysis framework that integrates CVE, CWE, CAPE, and CPE information related to the vulnerability based on ICS-CERT information (1843 cases). It also identifies assets of nuclear facilities by using CPE information and analyzes vulnerabilities using CVE and ICS-CERT. In the past, only 8% of ICS-CERT's vulnerability information was searched for information on any domestic nuclear facility during vulnerability analysis, but more than 70% of the vulnerability information could be searched using the proposed methodology.

Development Plan of Facility Importance, Risk, and Damage Estimation Inventory Construction for Assisting Disaster Response Decision-Making (재난대응 의사결정 지원을 위한 시설물 중요도·위험도·피해액 산정 인벤토리 구축 방안 연구)

  • CHOI, Soo-Young;GANG, Su-Myung;JO, Yun-Won;OH, Eun-Ho;PARK, Jae-Woo;KIM, Gil-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.167-179
    • /
    • 2016
  • The safety of SOC facilities is constantly under threat by the globally increasing abnormal climate. Responding to disasters requires prompt decision-making such as suggesting evacuation paths. For doing so, spatio-temporal information with convergence of disaster information and SOC facility information must be utilized. Such information is being collected separately by the government or related organizations, but not collectively. The collective control of the separately collected disaster information and the generation of SOC facility safety and damage information are required for prompt disaster response. Also, as disaster information requires spatio-temporal convergence in its nature, the construction of an inventory that integrates related information and assists disaster response decision-making is required. A plan to construct a facility importance, risk, and damage estimation inventory for assisting prompt disaster response decision-making is suggested in this study. Through this study, the disaster and SOC facility-related data, which are being managed separately, can be collected and standardized. The integrated information required for the estimation of facility importance, risk, and damage can be provided. The suggested system is expected to be used as a decision-making tool for proactive disaster response.

A Study of Integrated Community Welfare Facilities Planning for the Elderly - Focused on the case in Germany - (고령자를 위한 지역 통합적 복지시설 계획 - 독일의 사례를 중심으로 -)

  • Nam, Yun-Ok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.4 no.7
    • /
    • pp.75-84
    • /
    • 1998
  • Like all other European countries, as a result of gradual industrialization, Germany is just before the start of new social system; the so-called 'aged society'. Over half of the century, Germany focused their welfare system on facilities. However, with the start of the new 'aged society', they introduced a new concept which consists mainly on home care and community care. These new concepts resulted from the general idea that even elderly have the right to live an independent quality life. Therefore, to satisfy the elderly with such life it has been seen as necessary not only to offer them efficient protection but to introduce an economical welfare system and facility scheme. The regional integration plan for welfare is one of the open schemes in which the lifestyle of the elderly are seen as the whole. Participated by several members and specialists of all social standings, necessary facilities are planned. By looking into a project example carried out in Germany, this study is aimed to increase the quality of the elderly welfare system and facility construction plan.

  • PDF

A Study on the Establishment of Integrated Information System for School Facilities -on the Design Direction of Information Implementation- (학교시설 통합정보시스템 구축방안에 관한 연구 - 정보화 구축설계 방향을 중심으로 -)

  • Lee, Sang Min;Ro, Keun Chul;Yoo, Seung Ho
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.1
    • /
    • pp.30-38
    • /
    • 2017
  • Despite the fact that school facilities are one of the most important public facilities, information about school facilities is not systematically managed. The purpose of this study was to investigate the direction of system construction to provide objective data on school facilities, which is the basic element of school facility policy. In this study, we propose a system construction method to improve the information management procedure of school facility information and school facilities, and suggest a system design direction for providing service that can be practically used.

A study on data standardization and utilization for disaster and safety management in educational facilities (교육시설 재난안전관리를 위한 데이터 표준화 및 활용방안 연구)

  • Kang, Seong-Kyung;Lee, Young-Jai
    • The Journal of Information Systems
    • /
    • v.27 no.2
    • /
    • pp.175-196
    • /
    • 2018
  • Purpose The purpose of this study is to identify problems of current educational facility data management and recommend a standardized terminology classification system as a solution. In addition, the research aims to present a preemptive and integrated disaster and safety management framework for educational facilities by seeking efficient business processes through secured data quality, systematic data management, and external data linkage and analysis. Design/methodology/approach A terminology classification system has been established through various processes including filtering and analysis of related data including laws, manuals, educational facilities accidents, and historical records. Furthermore, the terminology classification system has been further reviewed through several consultations with experts and practitioners. In addition, the accumulated data was refined according to the established standard terminology and an Excel database was developed. Based on the data, accident patterns occurred in educational facilities over the past 10 years were analyzed. Findings In the study, a template was developed to collect consistent data for the standardized disaster and safety management terminology classification system in educational facilities. In addition, the standardized data utilization methods are presented from the viewpoint of 'education facility disaster safety data management', 'data analysis and insight', 'business management through data', and 'leaping into big data management'.

Energy Saving Potentials of Ventilation Controls Based on Real-time Vehicle Detection in Underground Parking Facilities

  • Cho, Hong-Jae;Park, Joon-Young;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.331-340
    • /
    • 2013
  • The main topic of this paper is to show a possibility of indoor air quality enhancement and the fan energy savings in underground parking facilities by applying the demand-controlled ventilation (DCV) strategy based on the real-time variation of the traffic load. The established ventilation rate is estimated by considering the passing distance, CO emission rate, idling time of a vehicle, and the floor area of the parking facility. However, they are hard to be integrated into the real-time DCV control. As a solution to this problem, the minimum ventilation rate per a single vehicle is derived in this research based on the actual ventilation data acquired from several existing underground parking facilities. And then its applicability to the DCV based on the real-time variation of the traffic load is verified by simulating the real-time carbon monoxide concentration variation. The energy saving potentials of the proposed DCV strategy is also checked by comparing it with those for the current underground parking facility ventilation systems found in the open literature.

Assessment of water quality in an artificial urban canal: A case study of Songdo City in South Korea

  • Ahn, Jungkyu;Na, Yeji;Park, Sung Won
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.582-590
    • /
    • 2019
  • Currently, the waterfront facility was constructed in New Songdo City, South Korea. It has the various water leisure areas and especially an artificial urban canal with filtered seawater by re-circulating flow system. However, due to excessive amount of nutrients from seawater combined with complicated geometry, it is highly vulnerable to deterioration of water quality. In this study, flow characteristics and pollutant transport were analyzed with comprehensive numerical models, MIKE 3 FM and ECO-lab. Based on these numerical results, notable sampling points were selected for field measurements and comparison between modeling and measured results were conducted. In addition, the integrated water quality evaluation index, Water Quality Index was applied to analyze various water quality issues. We also set up scenarios to control the two kinds of water quality factors, dissolved oxygen (DO), and total phosphorus (TP). As a result, the effect of 20% reduction of TP was less than 10% and it was almost ineffective for a year but it was reduced by up to 40% in case of scenario which DO is increased by 20%. Therefore, it was recommended to control the DO concentration, usually by applying re-aeration facility, rather than TP in artificial urban canal with seawater.

Experimental Study on Design Verification of New Concept for Integral Reactor Safety System (일체형원자로의 신개념 안전계통 실증을 위한 실험적 연구)

  • Chung, Moon-Ki;Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Park, Choon-Kyung;Lee, Sung-Jae;Song, Chul-Hwa
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2053-2058
    • /
    • 2004
  • The pressurized light water cooled, medium power (330 MWt) SMART (System-integrated Modular Advanced ReacTor) has been under development at KAERI for a dual purpose : seawater desalination and electricity generation. The SMART design verification phase was followed to conduct various separate effects tests and comprehensive integral effect tests. The high temperature / high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents) has been constructed to simulate the SMART-P (the one fifth scaled pilot plant) by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems. Heat transfer characteristics and natural circulation performance of the PRHRS (Passive Residual Heat Removal System) of SMART-P were also investigated using the VISTA facility. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant.

  • PDF

A Construction of the N-BMS Focused on the Building Service Equipment (N-BMS : National Building Management System) (건물 군관리시스템 구축방안)

  • Lee, Tae-Won;Kim, Yong-Ki;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.149-154
    • /
    • 2007
  • Now, in Korea, the performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. As the result, very different quality of the performance or the durability of equipment is being obtained with his skill and effort and it is also not easy to assess that quality. This finally lead to the waste of labor force and the operating cost due to the high-cost, low-efficiency system. How to construct the N-BMS was considered to save energy, resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF