• Title/Summary/Keyword: insulations

Search Result 118, Processing Time 0.026 seconds

Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings (노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교)

  • Lhee, Sang-Choon;Choi, Young-Joon;Kim, Hyun-Ki;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.

Charge Formation in PCB Insulations (PCB 절연체에서 전하 형성)

  • Lee, Joo-Hong;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.264-265
    • /
    • 2008
  • While the reliability of bulk insulation has become important particularly in multilayer boards and embedded boards, electronics are to be used under various environments such as at high temperature and in high humidity. We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF

An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment (에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석)

  • Kwon, Kyung-Woo;Won, Jong-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.33-38
    • /
    • 2009
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about $10.5{\sim}11.3%$, and cooling loads are decreased about $11.0{\sim}15.5%$ on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades, but the cooling peak load is hardly ever decreased. Because in the condition of cooling peak load, latent cooling loads accounts for large score of cooling loads. Difference of the energy loads by a schedule control method and an outdoor detection control was no more than 5% for a base model. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

  • PDF

A Study on the Thermal Characteristics of Comfortable Heat-Retaining Winter Clothing (겨울용 쾌적 보온성 의복의 온열특성에 관한 연구 - 무풍환경하에서 -)

  • Song, Min-Kyu;Kwon, Myoung-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.6
    • /
    • pp.24-34
    • /
    • 2008
  • The purpose of this study was to create a database of information on fabric factors(i.e., fabric insulation, fabric weight, clothing weight, fabric thickness, air permeability, and water vapor resistance) of clothing used for insulations, to compare them according to clothing types, and to estimate thermal resistance of clothing using these factors. A total of 25 kinds of clothing were selected(9 types for suits, 6 types of jacket, 5 types for shirts, and 5 types for trousers). The results of this study were as follows; Thermal insulation of clothing showed the highest positive correlation(0.85, p>0.01) with thermal insulation of fabric and very high positive correlation with water vapor resistance, fabric thickness, fabric weight, and clothing weight, respectively, 0.77, 0.77, 0.73, 0.71(p>0.01). Fabric weight of jacket was higher than that of shirts and trousers. Air permeability of shirts was the highest of clothing types. Clothing insulation of jacket was higher than that of shirts and trousers and its fabric insulation was also the highest of clothing types. Regression analysis showed that fabric thickness, water vapor resistance, and fabric weight would be useful factors for estimating the thermal resistance of clothing.

Insulation Reinforcement of the Electrical Power Cable Degradated by the Water Tree Using Silicon (실리콘을 이용한 수트리 열화된 전력 케이블의 절연 보강)

  • Kang, Hyeong-Gon;Park, Jun-Chae;Ko, Seok-Cheol;Lim, Sung-Hun;Lee, C.H.;Hanh, Y.B.;Han, B.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.468-471
    • /
    • 2003
  • Fault of under ground power cable occurs usually from the water tree such as the vented tree, the bow tree and the water-rich halo. The water tree penetrates to the polyethylene cable insulations. Sometimes, the water tree also diffuses to mother cable in the substation. In this paper, instead of replacement of the faulty cable, we tried to cure an electrical power cable degraded by the water trees with silicon injection method. And measured the results with the isothermal relaxation current analysis method. After cable cure, Chonil line was improved from 2.27 to 1.96 in a phase, from 2.148 to 2.020 in b phase, and from badness to 2.192 in c phase. And Keumam line was also improved from 2.419 to 1.920 in a phase, from 2.301 to 2.000 in b phase, and from badness to 1.957 in c phase.

  • PDF

Investigation of Small Current Interruption Performance for New Type of Interrupting Chamber in SF$_{6}$ Gas Circuit Breaker (신차단방식 SF$_{6}$ 가스 차단기의 소전류 차단성능 연구)

  • Song, Won-Pyo;Kweon, Ki-Yeoung;Lee, Jae-Sung;Song, Ki-Dong;Kim, Maeng-Hyun;Ko, Hee-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.519-526
    • /
    • 2005
  • This paper presents computer simulation results for developing new type of SF$_{6}$ Circuit Breaker in terms of cold gas flow after small current interruption. This cold gas flows down a nozzle into the chamber of a circuit breaker. There are many difficult problems in analyzing the gas flow due to complex geometry, moving boundary, shock wave and so on. When predicting the dielectric capability of a gas circuit breaker after interruption, the gas pressure and density distributions due to the cold gas must be considered in addition to the electrical field imposed across the gas. A self-coded computational fluid dynamics (CFD) program is used for the simulation of cold gas flow in order to evaluate the electrical field characteristic across open contacts and transient characteristics of insulations after small current interruption.

Impulse Tests for a Composite Solid Insulator for High Voltage Superconducting Power Applications (복합고체절연물의 극저온 절연성능 평가를 위한 임펄스 내전압시험)

  • Kim, W.S.;Ryu, S.D.;Hyun, O.B.;Kim, H.R.;Yim, S.W.;Yang, S.E.;Kim, H.S.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.24-27
    • /
    • 2011
  • High voltage insulation in cryogenic environment is one of big issues for development of superconducting power application, such as superconducting fault current limiter, transformer, transmission cable, and so on. We had proposed a composite solid insulator composed of plastics and polymer insulation sheets for a use of high voltage superconducting power applications. It is well known that the G10 FRP keeps its mechanical strength at very low temperature and the PPLP is very good insulator adopted as insulations for superconducting transmission cables. The composition of these two materials will show very good electrical and mechanical properties adequate for the insulation components of superconducting power applications, such as bushing, insulation barrier, and even for a cryostat. Dielectric strengths of prepared samples were measured at the temperature of boiling point of liquid nitrogen at atmospheric pressure, which will be presented in this paper to show a usefulness of this technique.

Effects of garment types on thermal insulation using a thermal manikin (의복 형태가 보온력에 미치는 영향;써멀 마네킹 착용 실험에 의한)

  • 손원교;백윤정
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.8
    • /
    • pp.1110-1118
    • /
    • 1999
  • This study was to examine the effects of garment types on thermal insulation using a thermal manikin. cotton polyester wool silk and rayon were selected as outer wears like a blouse a skirt slacks and one-piece for this study Acetate was chosen as a lining. Brief and upper innerwear with long sleeves(cotton) were also chosen as the innerwear. The results were as follows: 1. The thermal insulation of the garment of single layer was in proportion to the covering area of garment in all types of clothing. 2. On adding the innerwear or the lining or both the thermal insulation of the each garment of single layer were showed a different trends by garment types. The thermal manikin insulations of one-piece dress adding the innerwear was higher than those of blouse-skirt suits. The thermal insulation of one-piece dress adding the innerwear and lining was lower than those of blouse-skirt suits. 3. The increasing rates of thermal insulation of multi-layered garments had different value by garment types but garment made of rayon and silk were showed very high increasing rates of thermal insulation. 4. The increasing rates of the thermal insulation of one-piece dress added the lining the innerwear or both except polyester showed the highest value and then blouse-slacks suits' turn came ound Blouse-skirt suits had the lowest the increasing rates of thermal insualition value.

  • PDF

Mechanical Properties of Mica/Epoxy Composite Materials used in Genrator Stator Windings (발전기 고정자 권선에 사용되는 마이카/에폭시 복합재료의 기계적 특성에 관한 연구)

  • 김희동;김희곤;김태완;강도열
    • Electrical & Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.327-333
    • /
    • 1997
  • Experiments on mechanical fatigue were conducted using the specimens which were cut from hydrogen cooled generator(rated 22kV and 50OMW) stator windings. We have investigated the aged mechanism of mica/epoxy insulation systems under air or hydrogen by both the tensile and compressive loadings. The fracture of generator stator windings is generally affected by mechanical stress. Thus, the tensile strength test were conducted. In this case, the maximum strength and strain are quite different between sound and aged specimens. It is observed that low bonded interface parts of tapes generally have lower strength than those of normal tapes which causes stress. In order to estimate the effects of cyclic load by the electromagnetic forces while the generator starts/stops, the mechanical fatigue test was also conducted. It is confirmed that the equation of expected life depends on stress amplitude and number of cycles. Though the stress amplitude and number of cycles are very tiny, the tensile fatigue of aged specimens under hydrogen atmosphere is bigger than those under air. In the case of hydrogen atmosphere, the tensile stress gives bigger effect than the compressive one.

  • PDF

Measurement of Moisture Contents using Recovery Voltage Method and Karl-Fischer Method (Karl-Fischer법과 회복전압법을 이용한 수분량 검출 비교 특성)

  • Kim, Hyung-Min;Kim, Jae-Hoon;Kim, Ju-Han;Han, Sang-Ok;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.76-78
    • /
    • 2005
  • Moisture contents measurement is frequently used as one of parameters for degradation diagnosis of transformer insulation. In general Karl-Fisher method is mainly used for moisture contents till now. But this method is inconvenient because of dismounting transformer for sampling oil or paper, and also partial sampling. At latest Recovery Voltage Method(RVM) is noticed for complement of this method. RVM can directly estimate moisture contents of transformer insulations in field without dismounting transformer. In this paper the accelerated aging process of oil-paper samples have been investigated at a temperature up to 140$^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. Next to, we have estimated moisture contents using both Karl-Fisher Titration Method and RVM. And we have compared with Karl-Fisher Titration Method and RVM for estimating moisture contents. At last we have verified reliability of RVM which is new measurement method.

  • PDF