• Title/Summary/Keyword: insulation work

Search Result 190, Processing Time 0.025 seconds

A Study on the Sound Insulation Performance of Steel-Structured Apartment Buildings (I) (철골조 공동주택의 차음성능 실태조사에 관한 연구 (I))

  • Cha, Sang-Gon;Lee, Sang-Woo;Jung, Byung-Wook;Jeong, Dae-Up;Lee, Soo-Yeul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.151-156
    • /
    • 2000
  • The sound insulation performance of walls and floors for air-borne and structure-borne sounds in an apartment building is an important environmental factor which should be contemplated at the intial design stage for their thorough control. Recent increasing residents' demands for quality living spaces strongly urge the development of more accurate and efficient measurement and evaluation methods for the control of air-borne and structure-borne sound insulation. However, steel-structured apartment buildings, recently emerged as new building structures in the market, have not been thoroughly examined. The present work carried out an extensive survey for steel-structured apartment buildings, in an attempt to provide useful design data, and their sound insulation performances were compared with those of R.C. apartment buildings.

  • PDF

Effect of the Inner Side Dielectric Coating of the Tank on the Particle Movement for Improving of GIS Insulation Reliability (GIS 절연 신뢰성 향상을 위한 탱크 내면 코팅이 파티클 거동에 미치는 영향)

  • Lee, Bang-Wook;Koo, Ja-Yoon;Kim, Min-Kyu;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.267-269
    • /
    • 1996
  • In this work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when outer electrode was dielectric coated by epoxy resin. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various size of Cu conducting particle was used and different gas pressure was applied. To prove the coating effect on the gas insulation, different thickness of epoxy coated outer electrode have been considered and the lift-off voltage and flashover voltage have been analyzed. The results show that the dielectric coated electrode has an remarkable influence on the reducing particle behavior in GIS system and enhancing the GIS insulation reliability.

  • PDF

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.

A Experimental Investigation on the PD Characteristics depending on the various Artificial Voids In Epoxy Insulator (에폭시 절연체의 보이드 크기에 따른 부분방전 특성연구)

  • Choi, C.K.;Lee, J.S.;Kim, J,T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1853-1855
    • /
    • 2000
  • An experimental investigation has been performed in order to understand the $\Phi$-q-n characteristics related to the PD taking place from the various size of artificial defects inserted in epoxy insulation. In this purpose, PD has been detected simultaneously by two different methods such as commercialized PD detector(TE571) and our detection system using self designed CT type sensor. Under the presence of void in epoxy insulation, PD has been initiated at the voltages between 16kV and 20kV which are much lower than the dielectric strength of epoxy insulation (130kV/mm$\sim$l50kV/mm). And also it is revealed that $\Phi$-q-n characteristics have been observed to be dependent upon the size of the artificial defects. Throughout this work, the on site applicability of the self designed Sensor has also been proved by comparing the results with those from the commercialized PD detector. And more one, considerable basic data regarding the insulation, diagnosis could be provided to understand the presence of the voids possibly inserted into the epoxy insulation system of the power apparatus.

  • PDF

Dielectric composition of the double pancake coil interior (Double pancake 코일 내부의 절연구성 연구)

  • Joung, Jong-Man;Baek, Sung-Myeong;Kwak, Dong-Sun;Lee, Joung-Won;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.210-213
    • /
    • 2002
  • For insulation design of the superconducting transformer, many types of insulation tests should be carried out. To clarify the components of insulation for superconducting transformer, there are main four parts as 1ike that turn-to-turn interior of each primary and secondary windings, layer-to-layer between primary and secondary windings, and winding to grounded structures. The insulation components should meet the required withstand voltage of the system and enough safety factors must included. As the fundamental insulation characteristics, we tested surface flashover voltage of spacer that would place between the coils and would take the role of both cooling duct and insulator. The structure of spacer in practice vary depending on coil type, in this work we considered double pancake coil for the superconducting transformer. In this study we tested flashover voltages of several arrangement of spacer.

  • PDF

Insulation Diagnostics of Power Cables and Application to Real Distribution System (케이블 절연열화진단과 실 계통 적용)

  • Yi, Dong-Young;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF

Occupational Exposure to Refractory Ceramic Fibers in the Semiconductor Scrubber Manufacturing Industry

  • Song, Seungwhan;Kim, Sunju;Kim, Donghyeon;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • v.13 no.3
    • /
    • pp.357-363
    • /
    • 2022
  • Background: Refractory ceramic fibers (RCFs) are a suspected carcinogen but have been widely used as insulations. Depending on the temperature, RCFs can transform into crystalline SiO2, which is a carcinogen that can be present in the air during bulk RCF handling. This study analyzed the physicochemical and morphological characteristics of RCFs at high temperatures and determined the exposure levels during the semiconductor scrubber maintenance. Methods: Sampling was conducted at a company that manufactures semiconductor scrubbers using RCFs as insulation. Bulk RCF samples were collected both before and after exposure to a scrubber temperature of 700℃. Airborne RCFs were collected during scrubber maintenance, and their characteristics were analyzed using microscopes. Results: The components of bulk RCFs were SiO2 and Al2O3, having an amorphous structure. Airborne RCFs were morphologically different from bulk RCFs in size, which could negatively affect maintenance workers' health. 58% of airborne RCFs correspond to the size of thoracic and respirable fibers. RCFs did not crystallize at high temperatures. The exposure caused by airborne RCFs during the scrubber frame assembly and insulation replacement was higher than the occupational exposure limit. Conclusion: Workers conducting insulation replacement are likely exposed to airborne RCFs above safe exposure limits. As RCFs are suspected carcinogens, this exposure should be minimized through prevention and precautionary procedures.

The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge (부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단)

  • 김성홍;박재준;김재환
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

The Diagonosis of Treeing Breakdown Simultaneous Detection on Charge of Partial Discharge and Acoustic Emission Pulse (방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단)

  • Choi, J.K.;Kim, S.H.;Park, J.J.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1781-1783
    • /
    • 1996
  • Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with a artificial needle shape void by the charge of partial discharge and acoustic emission pulse in each phase angle area at the same time. We have analyzed the ${\Phi}-Q-n$ pattern and the insulation diagnosis of the samples using statistic operators such as charge magnitude and A.E pulse factor, skweness, kurtosis, G,C. Therefore, the relation between the charge of partial discharge and A.E pulse will be helpful and efficient to predict the breakdown just before the breakdown occure.

  • PDF

Studies of the Smoke Emission from Cellulose Fiber Insulation (셀룰로오스 단열재의 연기발생에 관한 연구)

  • Kim, Hong;Kang, Young-Goo
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.2
    • /
    • pp.12-17
    • /
    • 1994
  • Smoke evolved from burning cellulose insulation treated with boric acid-borax-alum as combustion retardants has been studied using a light absorption method. It has been shown that the quantity of smoke are decreased with the increase of oxygen concentration. Applied fire retardants did not increase smoke generation from investigated cellulose insulation in range of themal degradation without flaming. These same fire retardants increased from in the range of flaming combustion. The results of this work have been analysed using imperical equation, which correlated the smoke density at oxygen content of combustion transition. This equation may be. $\sigma$=$\sigma$$_{T}$ exp{-7.24$\times$10$^{-7}$ ( $O_2$ $O_{2.T}$)}Where $O_2$is the concentration of oxygen in the oxidizing gas, and $O_{2.T}$ refers to oxygen concentration of combustion transition.n.n.n.

  • PDF