• 제목/요약/키워드: insulation panel system

검색결과 51건 처리시간 0.029초

지역 건축물의 에너지 자립을 위한 패시브 외단열 복합패널 개발 연구 (Development of the Passive Outside Insulation Composite Panel for Energy Self-Sufficiency of Building in the Region)

  • 문선욱
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.11-18
    • /
    • 2018
  • The study aims to address the energy crisis and realize self-sufficiency of building as part of local energy independence, breaking away from a single concentrated energy supply system. It is intended to develop modules of the outside insulation composite panels that conform to passive certification criteria and for site-assembly systematization. The method of study first identifies trends and passive house in literature and advanced research. Second, the target performance for development is set, and the structural material is selected and designed to simulate performance. Third, a test specimen of the passive outside insulation curtain wall module designed is manufactured and constructed to test its heat transmission coefficient, condensation performance and airtightness. Finally, analyze performance test results, and explore and propose ways to improve the estimation and improvement of incomplete causes to achieve the goal. The final test results achieved the target performance of condensation and airtightness, and the heat transmission coefficient was $0.16W/(m^2{\cdot}K)$, which is $0.01W/(m^2{\cdot})K$ below the performance target. As for the lack of performance, we saw a need for a complementary design to account for simulation errors. It also provided an opportunity to recognize that insulated walls with performance can impact performance at small break. Thus, to be commercialized into a product with the need for improvement in the design of the joint parts, a management system is needed to increase the precision in the fabrication process.

사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구 (Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building)

  • 양자강;김철호;김강수
    • KIEAE Journal
    • /
    • 제16권2호
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

복합자재의 패널 간 화염확산방지에 따른 플래시오버 지연 효과에 대한 실험적 연구 (Experimental Study on the Flash Over Delay Effects according to the Prevention of Flame Spread between Composite Material Panels)

  • 김도현;조남욱
    • 한국화재소방학회논문지
    • /
    • 제31권2호
    • /
    • pp.1-8
    • /
    • 2017
  • 샌드위치패널은 건축물의 내 외벽 및 지붕구조에 사용되며 양면의 불연성재료와 단열용 심재로 구성된 복합자재이다. 뛰어난 단열성능과 경량 및 시공의 우수한 특성 대비 화재 시 패널간 결합부위를 통해 화염이 내부로 유입되어 심재가 쉽게 용융되며 급격한 화염확산으로 인명 및 재산피해를 발생시킨다. 현행 건축법은 건축물 마감재료에 대하여 소규모 시험편에 대한 화재시험방법으로 연소성능을 파악하며 규정한 성능기준에 합격한 제품을 사용하도록 한다. 외벽 마감재료의 경우 불연 준불연 성능확보 재료를 사용하거나 화재확산방지구조를 설치하도록 규정한다. 본 연구는 외벽 마감재료에 국한되어 적용하고 있는 화재확산방지 구조를 샌드위치패널 건축물에 적용하여 수평 수직 화재확산의 위험성의 차이를 확인하고자 하였다. 이에 샌드위치패널에 대하여 ISO 13784-1 시험방법을 통한 실물화재실험과 금속구조물을 이용하여 패널간 화염확산을 차단하는 시공을 통해 화염확산방지 적용 여부에 대한 연소거동과 그 효과를 측정하였다. 실험 결과 패널 조인트 부위의 화염확산방지구조 시공은 패널 내부의 화염확산을 지연하며 이에 따른 플래시오버 시간이 지연되어 복합자재 건축물의 화재안전확보에 중요한 요인으로 작용될 수 있음을 확인하였다.

현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발 (A Study on the Development of Rolled Dry Floor Heating System for Improving Workability)

  • 이규동;김준호;정창호;김동우;小川慶一郞
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

열저항 효과를 고려한 멤브레인식 LNG 저장탱크의 누설 안전성에 관한 연구 (On the Leakage Safety Analysis of Membrane LNG Storage Tank With Thermal Resistance Effects)

  • 김청균;조승현;서흥석;홍성호;이승림;김영규;권부길
    • 한국가스학회지
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2004
  • 본 연구에서는 멤브레인식 LNG 저장탱크의 누설 안전성을 목재와 PUF로 구성된 단열재 및 예응력 콘크리트(PC) 재질이 균일하다는 가정하에 열저항 평형온도 효과를 고려하여 유한요소법(FEM)으로 해석하였다. FEM 계산결과에 따르면, 목재와 PUF로 구성된 단열재 구조물은 누설 LNG에 의해 구조물 자체가 먼저 파손되므로 누설 안전성을 보장할 수 없다. 그러나, 내부탱크와 단열재가 동시에 파손되어도 외부탱크 PC 구조물은 강도 안전성을 확보하고 있으므로 누설 LNG를 최소 10일 정도는 안전하게 지연시킬 수 있어 멤브레인식 LNG 저장탱크 시스템의 누설 안전성은 확보될 수 있다.

  • PDF

단순화된 Mark III 방열판의 구조 강도 평가에 관한 연구 (Structural Strength Assessment of Simplified Mark III CS Plate)

  • 정한구;양영순
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.539-543
    • /
    • 2011
  • LNG cargo containment system (CCS) has the primary function of ensuring adequate thermal insulation with keeping natural gas below its boiling point. From the viewpoint of structural design, this LNG CCS can be treated as a laminated composite structure showing complex structural responses under the sloshing load which can be defined as a violent behavior of the liquid contents in cargo tanks due to external forced motions. As LNG CCS type, Mark III containment system from TGZ is considered in this paper and then its structural strength assessment is performed based on a simple higher-order shear deformation theory and maximum stress, maximum strain, Tsai-Wu failure criteria developed for laminated composite plates. The assessment is performed to the initial failure of the Mark III CS plate by investigating failure locations and loads.

  • PDF

코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석 (Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection)

  • 김청균
    • 한국가스학회지
    • /
    • 제13권6호
    • /
    • pp.9-14
    • /
    • 2009
  • 본 연구에서는 LNG 저장탱크의 단열재 공간에 설치된 코너프로텍션에 작용하는 응력 및 변형거동 특성을 FEM으로 해석하였다. 제시된 코너프로텍션은 기존의 멤브레인식 LNG 저장탱크의 강도안 전성과 LNG 누출안전성을 증대시킬 수 있다. LNG 저장탱크 시스템에 작용하는 응력과 변위 거동량을 단열재 상자, 멤브레인 내부탱크, PC 외부탱크에 대하여 해석하였다. 유한요소법으로 계산한 해석결과에 의하면, 내부탱크와 외부탱크 사이에 코너프로텍션을 설치한 새로운 LNG 멤브레인 저장탱크의 응력과 변형 거동량은 기존의 LNG 저장탱크에 비하여 현저하게 줄어드는 경향을 보여주고 있다. 이러한 현상은 LNG 저장탱크 시스템의 강도 안전성이 코너프로텍션을 설치함에 따라서 강성도가 증가하기 때문인 것으로 설명될 수 있다.

  • PDF

에코센터의 생태건축기술에 관한 연구 - 건축재료와 태양에너지활용시스템을 중심으로 - (A Study on the Eco-Tecnique of EcoCenter - Focused on the Building Material and Solar System -)

  • 최영호;심우갑
    • KIEAE Journal
    • /
    • 제4권2호
    • /
    • pp.65-72
    • /
    • 2004
  • Ecological architecture enables people to recycle and reuse architectural resources within the category of ecosystem and also to minimize the effect on environment in a whole process, including architectural planning, usage and exhaustion to use sustainable energies. Rammed earth wall construction method utilized in EcoCenter located in Crystalwaters ecological village in Austrailia is a good example, which maximizes its advantages and also covers its limits to use soil and wood as structural resources. In a case of wood, they used non-treated timber to minimize environmental load and utilized used materials in openings. In the roofs, aluminum coated steel which is plated with zinc collects rain effectively even though it is not regenerable. Nontoxic finishes and insulation in floor and ceiling with used papers are able to minimize its environmental load. Solar energy system applied in EcoCenter enables them to market extra energy with electricity companies as well as support needs of its own buildings to utilize photovoltaic panel system with PV panels. Passive solar system is planned effectively in heating and cooling to apply regenerative walls in a use of rammed earth wall construction and natural ventilation systems through openings.

철도차량용 알루미늄 압출재의 음향 투과손실 예측에 관한 연구 (A Method of Analysis to Predict Sound Transmission Loss of an Extruded Aluminum Panel for Use on Railway Vehicles)

  • 김관주;이준헌;김대용;김석현
    • 한국철도학회논문집
    • /
    • 제16권1호
    • /
    • pp.20-25
    • /
    • 2013
  • 고속철도 차량의 프레임은 굽힘 강성이 높고 가벼운 알루미늄 압출재를 이용하고 있으나, 그 차음성능은 동일 면밀도의 평판에 비하여 취약하다. 본 연구에서는 유한요소해석을 통하여 알루미늄 압출재의 음향투과 손실 값을 예측하는 방법을 제시하였다. 압출재를 유한요소로 모델링하고 무반사 방사조건, 시편의 경계 조건, 재질의 감쇠손실계수 등을 사용하여 투과손실을 예측하였으며, 해석결과의 신뢰도를 검증하기 위하여 압출재 시편을 대상으로 ASTM E2249-02에 근거한 투과손실을 측정하였다. 제시된 해석방법은 철도차량용 알루미늄 압출재의 차음특성을 설계단계에서 파악하고 대책을 수립하는데 유용하게 활용될 것이다.

도시철도 운행소음 저감용 훼어링시스템 연구 (A study on Fairing System for Traveling Noise Reduction in Urban Subway)

  • 최상춘;장원락;호경찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.659-666
    • /
    • 2009
  • As the density and height of the buildings nearby subway lines get higher, the unprecedented residents' appeals for noise are on the rise. Furthermore, in accordance with the revision of enforcement regulations on the Noise and Vibration Control Act, the night time noise standards have been reinforced by 5dB effective on January 1st 2010 and the appropriate measures shall be taken accordingly. For the settlement of the public grievances against noise and vibration generated on tracks in at-grade and elevated section, the installation of continuously-welded-rail, rail lubrication system, improved fastening system and higher noise barrier is currently executed. Nevertheless, the noise and vibration levels in some areas are still exceeding the limits required in the regulation. Among the measures, an installation of higher noise barrier or noise tunnel seems to be the most effective way; however, it has limitations owing to the structural stability of existing elevated structures. The paper in consideration of the local conditions and foreign practices discusses the installation of fairing system under the train body as an noise insulation panel in order to reduce the rolling noise and under-carriage noise. Based on the result of this study, a performance verification test during actual train operation is in progress for further study.

  • PDF