• Title/Summary/Keyword: insulation condition

Search Result 596, Processing Time 0.031 seconds

Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test (트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가)

  • 조한구;안명상;한세원;허종철;이운용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment (완화전류 측정에 의한 지중배전케이블의 열화진단)

  • Kim, Ju-Yong;Song, Il-Keun;Kim, Dong-Myung;Yun, Tae-Sang;Jeong, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF

Design and Fabrication of an Ultra-low Partial Discharge Measurement System (극미소 부분방전 측정시스템의 설계 및 제작)

  • Seo, Hwang-Dong;Song, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kwon, Jang-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

Characteristics of Critical Current Degradation with Bending Diameter of High Temperature Superconducting Cable (고온 초전도 케이블의 굽힘 직경에 따른 임계전류 저하 특성)

  • Kim Hae Joon;Kim J.H.;Cho J.W.;Sim K.D.;Bae J.H.;Kim H.J.;Seong K.C.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1067-1069
    • /
    • 2004
  • 22.9[kV]/50[MVA]/30[m] HTS transmission power cable has been developed and tested at Korea Electrotechnology Research Institute and LG Cable Company by 21 century center for applied superconductivity technology. It is necessary to measure of critical current degradations, AC loss, insulation test and etc at the HTS cable development. This paper is analyzed characteristics that critical current of HTS cable bending condition according to this paper. We will be able to decide the diameter of drum which HTS cable is wound around and minimum curvature radius of HTS cable from results of this research.

  • PDF

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

Numerical Analysis of Surface Discharge due to Particles Attached to the GIS spacer (GIS 스페이서에 파티클 부착시 연면방전과 전계해석)

  • Jang, D.G.;Lee, J.H.;Kwak, H.R.;Park, H.Y.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1788-1790
    • /
    • 2003
  • GIS is a typical power equipment with higher reliability. It is compact and safe because all the energized parts are enclosed by a sealed cylindrical tank which is filled with $SF_6$. Generally gas insulated power equipments like GIS are designed to have sufficient electrical strength to prevent partial discharges under normal operating condition. Despite of the careful processes in manufacturing, transporting and assembling, voids or particles can be created, resulting in partial discharges at electrically weak points. The key factors causing partial discharges in GIS are; particles, voids in solid insulation, protrusions, poor contact of metal components, etc. The particle can be attached on; spacers, electrodes, internal wall of the GIS tank. It also moves in GIS freely. Most of partial discharges are likely to occur when particles are attached to spacers. In this paper, the electrical characteristics of a surface discharge were investigated under various conditions by using simulation program of FEMLAB.

  • PDF

Partial Discharge Signal Denoising using Adaptive Translation Invariant Wavelet Transform-Online Measurement

  • Maheswari, R.V.;Subburaj, P.;Vigneshwaran, B.;Iruthayarajan, M. Willjuice
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.695-706
    • /
    • 2014
  • Partial discharge (PD) measurements have emerged as a dominant investigative tool for condition monitoring of insulation in high voltage equipment. But the major problem behind them the PD signal is severely polluted by several noises like White noise, Random noise, Discrete Spectral Interferences (DSI) and the challenge lies with removing these noise from the onsite PD data effectively which leads to preserving the signal for feature extraction. Accordingly the paper is mainly classified into two parts. In first part the PD signal is artificially simulated and mixed with white noise. In second part the PD is measured then it is subjected to the proposed denoising techniques namely Translation Invariant Wavelet Transform (TIWT). The proposed TIWT method remains the edge of the original signal efficiently. Additionally TIWT based denoising is used to suppress Pseudo Gibbs phenomenon. In this paper an attempt has been made to review the methodology of denoising the PD signals and shows that the proposed denoising method results are better when compared to other wavelet-based approaches like Fast Fourier Transform (FFT), Discrete Wavelet Transform (DWT), by evaluating five different parameters like, Signal to noise ratio, Cross-correlation coefficient, Pulse amplitude distortion, Mean square error, Reduction in noise level.

Film Thickness Dependences of Ac High Field Dissipation Current Waveform for LDPE (저밀도 폴리에틸렌에 있어서 전압 파형의 두께 의존성)

  • Yun, Ju-Ho;Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.349-350
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Dependence of the Partial Discharge Characteristics of Ultra-high Voltage Cable Insulators on the Measuring Temperature

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Hyuk-Jin;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.186-192
    • /
    • 2008
  • Cross linked polyethylene (XLPE) insulators are used as insulation in ultra-high voltage electric power cables. This study investigated the electrical properties of XLPE at different temperatures. The electrical properties of the changing tree phenomenon was examined as a function of temperature applied to the electrical conductors by measuring the partial discharge at $25^{\circ}C$ to $80^{\circ}C$ and applied voltages to the electrodes ranging from 1 kV to 40 kV. The activity of the partial discharge was examined at various temperatures using the K-means distribution. The results revealed the specimen at $80^{\circ}C$ to have the lowest inception voltage and breakdown voltage. In addition, the core of clusters was moved $0^{\circ}$ and $180^{\circ}$ at the positive region and $180^{\circ}$ and $360^{\circ}$ in the negative region in the K-means. The distribution of clusters was concentrated on the inception condition and spread out widely at the breakdown voltage.

Partial Discharge Diagnosis of Thermal Degradated PVC Cable (열열화된 PVC 케이블의 부분방전 진단)

  • Song, Ki-Tae;Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.208-214
    • /
    • 2011
  • In this thesis, the partial discharge according to applied voltage and variations of cross-sectional area and length of the conductor related to general condition for using cable was measured in order to study degradation diagnosis for 2-Core cable of the PVC insulator used in industrial fields for other safety installations. Also the thermal degradation conditions under various installation circumstances of cables were studied by assuming degradation conditions with each different degradation rate (50%, 67%, 100%) such as variation in degradated temperature, thermal exposure time, normal state, partially degradated state and overall degradated state for thermal degradation diagnosis. The quantity of electric discharge (V-Q) according to applied voltage was measured for measurement of inception voltage and extinction voltage. The quantity of electric discharge and the number of electric discharge (Q-N) were measured with applied voltage kept constantly. In addition, pictures were taken using SEM (scanning electron microscope) to compare the surface of external insulator to degradated state of internal insulator according to thermal degradation temperature and also compare the surface of external insulator to degradated surface state of internal insulator according exposure time of cables to thermal stress.