• Title/Summary/Keyword: instrument analysis

Search Result 2,143, Processing Time 0.036 seconds

A Study on the Development of the Korean Family Functioning Scale. (한국형 가족 기능 측정 도구 개발을 위한 연구 - 만성질환아 가족을 대상으로 -)

  • ;;;;Hesook Suzie, Kim
    • Journal of Korean Academy of Nursing
    • /
    • v.32 no.3
    • /
    • pp.395-405
    • /
    • 2002
  • The purpose of this study was to develop the instrument to measure family functioning for Korean family with a chronic ill child, and to test the validity and reliability of the instrument. Method: The items of instrument were consisted based on researchers' previous study of concept analysis of the Korean family functioning. Twenty six item scale was developed with six domains. In order to test reliability and validity of the scale, data were collected from the 231 families, who have a child with a chronic illness. Data was collected between August and September in 2001 in a General Hospital in Seoul, Korea. Result: The results were as follows: As a result of the item analysis, 24 items were selected from the total of 26 items, excluding items with low correlation with total scale. Six factors were evolved by factor analysis. Six factors explained 61.4% of the total variance. The first factor 'Affective bonding' explained 15.4%, 2nd factor 'External relationship' 11.8%, 3rd factor 'Family norm' 10.5%, 4th factor 'Role and responsibilities' 8.3%, 5th factor ' Communication' 7.9%, and the 6th factor 'Financial resource' explained 7.3%. Cronbach's $\alpha$ coefficient of this scale was .87 and Guttman spilt- half coefficient was .84. Conclusion: The study support the reliability and validity of the scale. There were distinct differences in dimensions of family functioning scales developed in the U. S.

Development of an Instrument to Measure the Motivation for Rehabilitation in the Disabled (장애인의 재활 동기 측정도구 개발)

  • Han, Hye-Sook;Lim, Nan-Young
    • Korean Journal of Adult Nursing
    • /
    • v.14 no.4
    • /
    • pp.554-563
    • /
    • 2002
  • Purpose: to develop an instrument to assess the rehabilitation motivation and to test its reliability and validity. Method: The data was collected with in-depth interviews of nine participants that include adults with disabilities acquired after they reached 18 years' of age. The development of the preliminary items was based on the theory of self-determination proposed by Deci & Ryan (1985) and the results from the analysis of the data. After these, appropriate specialists clarified the validity of the contents of the preliminary items twice. A test to reliability and validity was conducted with 186 disabled. A principal axis factor analysis with oblimin rotation was performed on 29 items. Result: Finally 27 items were selected. The 5-factor solution emerged as the most appropriate model for the data. The different types of motivation for rehabilitation were identified as: task-oriented motivation, change-oriented motivation, obligatory motivation, external motivation, and amotivation. The alpha coefficient of internal consistency was .85. Conclusion: The results of this study suggest that the instrument to measure motivation for the rehabilitation of the disabled may be a useful instrument with a high degree of reliability and validity.

  • PDF

Development of Instrument for Korean Osteoarthritis Impact Measurement Scale (KAIMS) in Hip and Knee Osteoarthritis (한국형 골관절염영향측정척도(KAIMS) 도구개발 - 무릎 및 엉덩관절의 골관절염환자 중심 -)

  • Yi, Seung-Ju;Kim, Jin-Seop
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.82-89
    • /
    • 2014
  • Purpose: This study was conducted in order to develop an instrument for the Korean Osteoarthritis Impact Measurement scale (KAIMS) in hip and knee osteoarthritis patients. Methods: A sample of 426 subjects was recruited in Ulsan metropolitan city (six hospitals and clinics) and Andong city (five hospitals and clinics) from June 2010 to May 2011. Item internal consistency and item discriminant validity were analyzed on the item-level, and floor (%) and ceiling (%) effect were analyzed on the scale-level. Exploratory factor analysis was performed for construction of items in the KAIMS instrument; confirmative factor analysis was also performed to test the fit of the model. Results: In 426 respondents, age was 64.3 years. The reliability for r coefficient 0.90 (mobility) and 0.89 (pain and stiffness) (Cronbach's alpha 0.95, 0.95 respectively) was high in the test-retest, and there was no significant difference in paired t-test (p>0.05). Item internal consistency (${\alpha}=0.92$, ${\alpha}=0.87$ respectively) was also high. It was constructed of two factors (mobility, pain and stiffness dimension) and nine items in explanatory factor analysis; results of confirmatory factor analysis also indicated that the dimensional structure model was fitted well in the test of model fit (${\chi}^2=83.83$, df=26, p=0.000; RMR=0.05; GFI=0.96; AGFI=0.83). Conclusion: In conclusion, the results of this study showed that the KAIMS that was developed was a reliable and valid instrument for measurement of osteoarthritis (OA) patients. We recommend further research for additional development of the instrument on OA in Korea.

CHOOSING AN NIR INSTRUMENT AND A SAMPLE PRESENTATION OPTION PLANT AND SOIL ANALYSIS

  • Batten, Graeme-D;Blakeney, Anthony-B;Susan Ciavarella
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1022-1022
    • /
    • 2001
  • To obtain accurate and repeatable analyses using NIR technology it is important to select an NIR instrument and / or its sample presentation attachments which allow the operator to minimize sampling errors without compromising the benefits of NIR analysis -namely rapid, low cost, minimal sample preparation, minimal structural facilities, minimal hazards. For each sample type and consistency there may be different optimal combinations of instrument, sample presentation attachment, and sample preparation. This paper will consider options available to NIR users in the area of plant and soil analysis and evaluate the potential benefits and disadvantages of crop nutrient diagnoses using laboratory based and airborne imaging techniques.

  • PDF

Validity and Reliability of Korean Version of the Revised Tuberculosis Interview Instrument(K-TII) of Early Childhood Teachers (영유아 교사에 대한 한국어판 수정된 결핵예방 행동의도 측정도구의 타당도와 신뢰도)

  • Son, Jihee;Choi, Yun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.4
    • /
    • pp.520-531
    • /
    • 2017
  • The purpose of this study was to test the validity and reliability of the Korean version of the Tuberculosis Interview Instrument (K-TII). The instrument was first translated into Korean, back-translated to English, and reviewed. After the translation process, the instrument was revised from 52 items to 37 items by researchers and an expert according to the systematic review. In addition, these items were reduced to 32 items after the content validity test was done by 9 experts. As a result of pilot study conducted in 20 early childhood teachers, 32 items were selected for the preliminary instrument. Data collected from 289 early childhood teachers were used to test the validity and reliability of the preliminary instrument. The result of factor analysis showed that the instrument categorized into 7 factors explaining 71% of the total variance and 27 items were retained for the final instrument. The result of Cronbach's ${\alpha}$ coefficient was .88. In conclusion, the K-TII may be a suitable instrument for assessing tuberculosis prevention behaviors in early childhood teachers in Korea.

Characterization of Spherical Particles by Light Scattering

  • Sangwook Park;Jungmoon Sung;Taihyun Chang
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.322-328
    • /
    • 1991
  • We have studied a characterization method of accurate size of spherical particles by fitting experimental light scattering profile to the rigorous theoretical scattering function. An efficient software has been developed for computation of the theoretical scattering function and regression analysis. A light scattering instrument has been built and the necessary data acquisition and analysis are carried out by use of a personal computer with an emphasis on the reduction of analysis and time aiming that this study will be extended toward a development of a practical particle sizing apparatus. The performance of the instrument and the software has been evaluated with latex spheres and found to be satisfactory.

Analysis of Chung-Buk Regional Industry Trends -Focused on Machinery Part Industry and Medial Instrument Industry (충북지역 특화산업 현황 분석 -기계부품(자동차), 의료기기산업을 중심으로)

  • Lee, Hyoung-wook;Seo, JunHyeok;Park, Sung-jun;Bae, Sungmin
    • Journal of Institute of Convergence Technology
    • /
    • v.6 no.2
    • /
    • pp.41-46
    • /
    • 2016
  • Based on Regional Industry Development Plan in 2014, machinery part industry and medical instrument industry has been designated as core industries of Chung-buk area. Machinery part industry plays an important role in economic growth of chung-buk area and it has been faced with signigicant changes - such as SMART factory and IoT(Internet of things). Also, medical instrument industry with 3D printing technology grows rapidly in Chung-buk area. It is believed that medical instrument could be next cash-cow items for Chung-buk area. In this paper, we survey, analyze and summarize the current machinery part industry and medical instrument industry focused on Chunk-buk Area.

Development of a Tool to Measure Suffering in Patients with Cancer (암환자의 고통 측정도구 개발에 관한 연구)

  • 강경아
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.6
    • /
    • pp.1365-1378
    • /
    • 1999
  • This study is a methodological research study to develop an instrument to measure in patients with cancer and to test the validity and reliability of the instrument. The research procedure was as follows : 1) The first step was to develop conceptual framework based on a comprehensive review of the literature and in-depth interviews with patients with cancer. This conceptual framework was organized in to three dimensions (the intrapersonal dimension, the significant-other and context related dimension, the transcendental dimension). Initially 59 items were adopted. 2) These items were analyzed through the index of content validity(CVI) and 53 items were selected which met more than 80% on the CVI. 3) The pretest was carried out with 87 patients with cancer. After the pretest results were analyzed by item analysis, 44 items were selected. A second test of content validity was conducted and 6 items were eliminated considering the 80% CVI. 4) To test for reliability and validity, data collection was done during the period from January 25, 1999, to February 26, 1999. The subjects for the test were 160 patients with cancer and 185 healthy persons. analysis, item analysis and multitrait-multimethod method to analyze validity. The findings are as follows : 1) The Cronbach's alpha coefficient for internal consistency was .92 for the total 38 items and .79, .82, .85, for the three dimensions in that order. 2) The item analysis was based on the corrected item to total correlation coefficient( .30 or more) and information about the alpha estimate if this item was dropped from the scale. 3) As a result of the initial factor analysis using principal component analysis and varimax rotation, one item was deleted because of factor complexity (indiscriminate factor loadings). In the secondary factor analysis, 7 factors with eigenvalue of more than 1.0 were extracted and these factors explained 56 percents of the total variance. The seven factors were labeled as 'family relationship', 'emotional condition', 'physical discomfort', 'meaning and goal of life', 'contextual stimuli', 'change of body image', 'guilt feelings'. 4) The convergence effect between this instrument and the life satisfaction scale was identified and there was significant positive correlation(r= .52, p= .00). The discriminant validity between this instrument and the depression scale(CES-D) was tested and there was significant negative correlation(r= -.50, p= .00). The instrument for accessing the suffering of patients with cancer developed in this study was identified as a tool with a high degree of reliability and validity. In this sense, this tool can be effectively utilized for assessment in caring for patients with cancer.

  • PDF

The development of an Instrument for Measuring the Creative Engineering Problems Solving Propensity for STEAM (융합인재교육(STEAM)을 위한 창의적 공학문제해결 성향 검사 도구 개발)

  • Kang, Ju-Won;Nam, Younkyeong
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.9 no.3
    • /
    • pp.276-291
    • /
    • 2016
  • This study is to develop a valid and reliable instrument for measuring students' creative engineering problem solving propensity. The creative engineering problem solving is operationally defined in this study as a creative problem solving skill in an engineering context. To develop the instrument, first we define seven common constructs between engineering problem solving skill and creative problem solving skill through an intensive literature review; motivation, context, personal character, engineering design, engienering habits of mind, understandings of engineering and engineers, communication skill, and collaboration skill. Based on the seven constructs and the face validity test conducted by two in-service science teachers and 4 experts in science education research, 40 preliminary items were developed. Then the preliminary instrument was implemented in a science gifted highschool to measure the reliability of the instrument. From the 40 items, 34 items were selected through the initial reliability test by Cronbach's ${\alpha}$(>.75). Finally through the three times of factor analysis process, 28 items in five construct categories were selected; motivation (3 items), engineering design (6 items), engineering habits of mind (9 items), understandings of engineering and engineers (4 items), communication and collaboration skill (6 items). The factor analysis result showed that the reliability of each construct category was between .733 to .892., meaning that the instrument is reliable in terms of the higher structural validity (each item is categorized in an appropriate construct category). We expect that the creative engineering problem solving propensity instrument developed in this study can be used in various contexts for STEAM education research as a reliable and valid instrument.

Transferring Calibrations Between on Farm Whole Grain NIR Analysers

  • Clancy, Phillip J.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1210-1210
    • /
    • 2001
  • On farm analysis of protein, moisture and oil in cereals and oil seeds is quickly being adopted by Australian farmers. The benefits of being able to measure protein and oil in grains and oil seeds are several : $\square$ Optimize crop payments $\square$ Monitor effects of fertilization $\square$ Blend on farm to meet market requirements $\square$ Off farm marketing - sell crop with load by load analysis However farmers are not NIR spectroscopists and the process of calibrating instruments has to the duty of the supplier. With the potential number of On Farm analyser being in the thousands, then the task of calibrating each instrument would be impossible, let alone the problems encountered with updating calibrations from season to season. As such, NIR technology Australia has developed a mechanism for \ulcorner\ulcorner\ulcorner their range of Cropscan 2000G NIR analysers so that a single calibration can be transferred from the master instrument to every slave instrument. Whole grain analysis has been developed over the last 10 years using Near Infrared Transmission through a sample of grain with a pathlength varying from 5-30mm. A continuous spectrum from 800-1100nm is the optimal wavelength coverage fro these applications and a grating based spectrophotometer has proven to provide the best means of producing this spectrum. The most important aspect of standardizing NIB instruments is to duplicate the spectral information. The task is to align spectrum from the slave instruments to the master instrument in terms of wavelength positioning and then to adjust the spectral response at each wavelength in order that the slave instruments mimic the master instrument. The Cropscan 2000G and 2000B Whole Grain Analyser use flat field spectrographs to produce a spectrum from 720-1100nm and a silicon photodiode array detector to collect the spectrum at approximately 10nm intervals. The concave holographic gratings used in the flat field spectrographs are produced by a process of photo lithography. As such each grating is an exact replica of the original. To align wavelengths in these instruments, NIR wheat sample scanned on the master and the slave instruments provides three check points in the spectrum to make a more exact alignment. Once the wavelengths are matched then many samples of wheat, approximately 10, exhibiting absorbances from 2 to 4.5 Abu, are scanned on the master and then on each slave. Using a simple linear regression technique, a slope and bias adjustment is made for each pixel of the detector. This process corrects the spectral response at each wavelength so that the slave instruments produce the same spectra as the master instrument. It is important to use as broad a range of absorbances in the samples so that a good slope and bias estimate can be calculated. These Slope and Bias (S'||'&'||'B) factors are then downloaded into the slave instruments. Calibrations developed on the master instrument can then be downloaded onto the slave instruments and perform similarly to the master instrument. The data shown in this paper illustrates the process of calculating these S'||'&'||'B factors and the transfer of calibrations for wheat, barley and sorghum between several instruments.

  • PDF