• Title/Summary/Keyword: instantaneous period

Search Result 91, Processing Time 0.022 seconds

Current Control Method for Torque Ripple Reduction in Brushless DC Motor (브러시리스 직류 전동기의 토크 맥동 저감을 위한 전류 제어 방식)

  • 이광운;홍희정;박정배;여형기;이인호;유지윤
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.191-198
    • /
    • 1998
  • This paper presents a new current control method to reduce the torque ripple due to phase commutation, when the unipolar PWM method is applied for the phase current control of brushless DC motor. Phase commutation bring about an instantaneous change in the average voltage of conducting phase so that current undulates, and this undulating current generates torque ripple. In this paper, we analyze average voltage variations of conducting phase in commutation period with PWM pattern and design current controller to compensate average variations. In addition, we prove the validity of proposed method by experimental results.

  • PDF

A Study on the Measurement of Back Muscle Fatigue During Dynamic Contraction Using Multiple Parameters (다중 파라메터를 이용한 동적 수축시 허리 근육 피로 측정에 관한 연구)

  • Yoon, Jung-Gun;Jung, Chul-Ki;Yeo, Song-Phil;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.344-351
    • /
    • 2006
  • The fatigue of back muscle in the repetitive lifting motion was studied using multiple parameters(FFT_MDF, RMS, 2C, NT) in this study. Recent developments in the time-frequency analysis procedures to compute the IMDF(instantaneous median frequency) were utilized to overcome the nonstationarity of EMG signal using Cohen-Posch distribution. But the above method has a lot of computation time because of its complexity. So, in this study, FFT_MDF(median frequency estimation based on FFT) algorithm was used for median frequency estimation of back muscle EMG signal during muscle work in uniform velocity portion of lumbar movement. The analysis period of EMG signal was determined by using the run test and lumbar movement angle in dynamic task, such as lifting. Results showed that FFT_MDF algorithm is well suited for the estimation of back muscle fatigue from the view point of computation time. The negative slope of a regression line fitted to the median frequency values of back muscle EMG signal was taken as an indication of muscle fatigue. The slope of muscle fatigueness with FFT_MDF method shows the similarity of 77.8% comparing with CP_MDF(median frequency estimation based on Cohen Posch distribution) method.

NUMERICAL STUDY ON THE CLOCKING EFFECT IN A 1.5 STAGE AXIAL TURBINE (1.5단 축류터빈에서의 Clocking 효과에 관한 수치적 연구)

  • Park, Jong-Il;Choi, Min-Suk;Baek, Je-Hyun
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.1-8
    • /
    • 2006
  • Clocking effects of a stator on the performance and internal flow in an UTRC 1.5 stage axial turbine are investigated using a three-dimensional unsteady flow simulation. Six relative positions of two rows of stator are investigated by positioning the second stator being clocked in a step of 1/6 pitch. The relative efficiency benefit of about 1% is obtained depending on the clocking positions. However, internal flows have some different characteristics from that in the previous study at the best and worst efficiency positions, since the first stator wake is mixed out with the rotor wake before arriving at the leading edge of the second stator. Instead of the first stator wake, it is found that the wake interaction of the first stator and rotor has a important role on a relative efficiency variation at each clocking position. The time-averaged local efficiency along the span at the maximum efficiency is more uniform than that at the minimum efficiency. That is, the spanwise efficiency distribution at the minimum efficiency has larger values in mid-span but smaller values near the hub and casing in comparison to those at the maximum efficiency. Moreover, the difference between maximum and minimum instantaneous efficiencies during one period is found to be smaller at the maximum efficiency than at the minimum efficiency.

Development of a Time-selective Self-triggering Water Sampler and Its Application to In-situ Calibration of a Turbidity Sensor

  • Jin, Jae-Youll;Hwang, Keun-Choon;Park, Jin-Soon;Yum, Ki-Dai;Oh, Jae-Kyung
    • Journal of the korean society of oceanography
    • /
    • v.34 no.4
    • /
    • pp.200-206
    • /
    • 1999
  • Seawater sampling is the primary task for the study of the marine environmental parameters that require shipboard or laboratory experiments for their analyses, and is also required for the calibration of some instruments for in situ measurement. A new automatic bottle (AUTTLE) is developed for seawater sampling at any desired time and water depth by self-triggering. Both any type of single or assembled mooring for 15 days and manual actuation by using a remote messenger as existing instantaneous single point water samplers are possible. Its sampling capacity and the resolution of time setting are 2 liters and 1 second, respectively. The result of a field experiment with an optical backscattering sensor (OBS) and a total of 14 AUTTLES for the in situ calibration of the OBS shows that the AUTTLE must improve our understanding on the behavior of the sand/mud mixtures in the environments with high waves and strong tides. The AUTTLE will serve as a valuable instrument in the various fields of oceanography, especially where synchronized seawater sampling at several sites is required and/or the information in storm period is important.

  • PDF

Influence of Typhoon Landfall and Its Track Characteristics in Gyeongsangbuk-do (경상북도에서 태풍에 의한 영향과 유형별 진로 특성 분석)

  • Park, Doo-Seon;Ho, Chang-Hoi;Hwang, Jongkook
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.525-532
    • /
    • 2008
  • This study has examined influences of tropical cyclone (TC) landfalls on the Gyoengsangbuk-do region, located in southeast of Korea, for the period 1978-2006. This region is known as one of major pass ways of landfalling TCs, and has many cultural properties including Bulguksa, Sukgulam, etc. Thus the influences caused by TCs (i.e., TC damages) may be larger than elsewhere in the nation. Here, TC influence is defined as the cases of strong instantaneous wind speed (${\geq}20ms^{-1}$) and heavy rainfall (${\geq}100mmday^{-1}$) at each station. This study analyzed long-term trends ofTC influences and the relationship with TC tracks are examined. As a result, it is found that large increase of the heavy rainfall cases along the coastal region. By contrast, there are marginal changes in the strong wind speed associated with TC landfalls. Further, it is also found that the cases of the heavy rainfall only are related with TCs passing through the Yellow Sea and the cases of both the strong wind and the heavy rainfall are related with TCs landing from southern Korea.

Numerical Study on the Clocking Effect in a 1.5 Stage Axial Turbine (1.5단 축류 터빈에서의 Clocking 효과에 관한 수치적 연구)

  • Park, Jong-Il;Choi, Min-Suk;Baek, Je-Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.473-480
    • /
    • 2005
  • Clocking effects of a stator on the performance and internal flow in an UTRC 1.5 stage axial turbine are investigated using a three-dimensional unsteady flow simulation. Six relative positions of two rows of stator are investigated by positioning the second stator being clocked in a step of 1/6 pitch. The relative efficiency benefit of about 1% is obtained depending on the clocking positions. However, internal flows have some different characteristics from that in the previous study at the best and worst efficiency positions, since be first stator wake is mixed out with the rotor wake before arriving at the leading edge of the second stator. Instead of the first stator wake, it is found that the wake interaction of the first stator and rotor has a important role on a relative efficiency variation at each clocking position. The time-averaged local efficiency along the span at the maximum efficiency is more uniform than that at the minimum efficiency. That is, the spanwise efficiency distribution at the minimum efficiency has larger values in mid-span but smaller values near the hub and casing in comparison to those at the maximum efficiency. Moreover, the difference between maximum and minimum instantaneous efficiencies during one period is found to be smaller at the maximum efficiency than at the minimum efficiency.

  • PDF

Monitoring of Non-point Source Pollutants Generated by a Flower Farm

  • Choi, Byoungwoo;Kang, Meea
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.463-471
    • /
    • 2014
  • This paper considers the effect of rainfall on non-point source (NPS) pollutant loads. The impact of runoff on the occurrence of NPS pollutants was found to be influenced by rainfall amount, rainfall intensity, and the number of antecedent dry days (ADD), both independently and in combination. The close correlation ($R^2$ = 0.9920) between rainfall and runoff amounts was demonstrated at the study site (a flower farm) over the period between January 2011 and December 2013. The relationships among pollutant levels, runoff, and rainfall was not satisfactory results except for the Biochemical Oxygen Demand ($BOD_5$). The correlation coefficients between $BOD_5$, and both runoff and rainfall, were greater than 0.92. However, the relationships of other pollutants, such as Suspended Solid (SS), Chemical Oxygen Demand ($COD_{Mn}$), Total Nitrogen (TN), and Total Phosphorus (TP), with runoff and rainfall had correlation coefficients of less than 0.70. The roles of rainfall was different from rainfall categories on the occurrence of runoff. Instantaneous rainfall intensity was a principle factor on the occurrence of runoff following light rainfall events (total ${\leq}30mm$). For rainfall of intermediate intensity (total precipitation 31-50 mm), the combined effect of both average rainfall intensity and ADD was found to influence runoff generation. We conclude that the control of NPS pollutants with the reflection of the climate change that makes the remarkable effect of amounts and forms on the rainfall and runoff.

HAZARD ANALYSIS OF TYPHOON-RELATED EXTERNAL EVENTS USING EXTREME VALUE THEORY

  • KIM, YOCHAN;JANG, SEUNG-CHEOL;LIM, TAE-JIN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.59-65
    • /
    • 2015
  • Background: After the Fukushima accident, the importance of hazard analysis for extreme external events was raised. Methods: To analyze typhoon-induced hazards, which are one of the significant disasters of East Asian countries, a statistical analysis using the extreme value theory, which is a method for estimating the annual exceedance frequency of a rare event, was conducted for an estimation of the occurrence intervals or hazard levels. For the four meteorological variables, maximum wind speed, instantaneous wind speed, hourly precipitation, and daily precipitation, the parameters of the predictive extreme value theory models were estimated. Results: The 100-year return levels for each variable were predicted using the developed models and compared with previously reported values. It was also found that there exist significant long-term climate changes of wind speed and precipitation. Conclusion: A fragility analysis should be conducted to ensure the safety levels of a nuclear power plant for high levels of wind speed and precipitation, which exceed the results of a previous analysis.

SARAPAN-A Simulated-Annealing-Based Tool to Generate Random Patterned-Channel-Age in CANDU Fuel Management Analyses

  • Kastanya, Doddy
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.267-276
    • /
    • 2017
  • In any reactor physics analysis, the instantaneous power distribution in the core can be calculated when the actual bundle-wise burnup distribution is known. Considering the fact that CANDU (Canada Deuterium Uranium) utilizes on-power refueling to compensate for the reduction of reactivity due to fuel burnup, in the CANDU fuel management analysis, snapshots of power and burnup distributions can be obtained by simulating and tracking the reactor operation over an extended period using various tools such as the $^*SIMULATE$ module of the Reactor Fueling Simulation Program (RFSP) code. However, for some studies, such as an evaluation of a conceptual design of a next-generation CANDU reactor, the preferred approach to obtain a snapshot of the power distribution in the core is based on the patterned-channel-age model implemented in the $^*INSTANTAN$ module of the RFSP code. The objective of this approach is to obtain a representative snapshot of core conditions quickly. At present, such patterns could be generated by using a program called RANDIS, which is implemented within the $^*INSTANTAN$ module. In this work, we present an alternative approach to derive the patterned-channel-age model where a simulated-annealing-based algorithm is used to find such patterns, which produce reasonable power distributions.

Distortion Elimination for Buck PFC Converter with Power Factor Improvement

  • Xu, Jiangtao;Zhu, Meng;Yao, Suying
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.10-17
    • /
    • 2015
  • A quasi-constant on-time controlled buck front end in combined discontinuous conduction mode and boundary conduction mode is proposed to improve power factor (PF).When instantaneous AC input voltage is lower than the output bus voltage per period, the buck converter turns into buck-boost converter with the addition of a level comparator to compare input voltage and output voltage. The gate drive voltage is provided by an additional oscillator during distortion time to eliminate the cross-over distortion of the input current. This high PF comes from the avoidance of the input current distortion, thereby enabling energy to be delivered constantly. This paper presents a series analysis of controlling techniques and efficiency, PF, and total harmonic distortion. A comparison in terms of efficiency and PF between the proposed converter and a previous work is performed. The specifications of the converter include the following: input AC voltage is from 90V to 264V, output DC voltage is 80V, and output power is 94W.This converter can achieve PF of 98.74% and efficiency of 97.21% in 220V AC input voltage process.