• Title/Summary/Keyword: inspection and diagnosis

Search Result 464, Processing Time 0.035 seconds

Self-Diagnosis Property of Fracture in Carbon Fiber Composite Mortar (탄소섬유 분말 혼입 모르타르 복합 구조체의 파괴예측 자가진단 특성)

  • Park, Seok-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.113-120
    • /
    • 2007
  • A new material was tested and its applicability was investigated so as to give the capability of self-diagnosis of fracture in composite mortar. In the research for giving self-diagnosis capability, conductive mortar intermixed with cokes and carbon fiber powder(milled carbon fiber) was developed and its using for self-diagnosis material was proposed. Then after examining change in the value of electric resistance and AE characteristics before and after the occurrence of cracks at each weight-stage, the relationships of each factors were analyzed. As the results, it can be recognized that a new composite material with cokes and carbon fiber powder(milled carbon fiber) can be applied for self-diagnosis of fracture in mortar specimen.

CHEMILUMINESCENCE IN DIAGNOSIS OF ORAL LICHEN PLANUS (화학 발광 검사법을 이용한 구강 편평 태선의 진단)

  • Myoung, Hoon;Jeong, Hae-Seok;Lee, Hyun-Sun;Hong, Soon-Min;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.281-287
    • /
    • 2007
  • Purpose: This study was conducted in order to evaluate how chemiluminescent lighting($ViziLite^{(R)}$) could increase the sharpness of margin and contrast to normal mucosa in the diagnosis of oral lichen planus(OLP), the most frequent oral premalignant lesion, compared with direct visual inspection under incandescent light. Methods: 41 consecutive patients, diagnosed to have OLP with visual inspection under incandescent light, were further examined with chemiluminescent light. The degrees of margin sharpness and lesion contrast were ranked on a scale from 1 to 3 for all patients under visual inspection and chemiluminescent light. The presence of additional lesion only detected by chemiluminescent light, complication, and discomfort were checked for each patient. After both screening tests, biopsy specimens were harvested from all patients with scalpels and histopathologic assessments were done. Results: All 41 patients were diagnosed to have OLP by both visual inspection and chemiluminescent light examination. This result was definitively diagnosed by histopathology. Degrees of margin sharpness and lesion contrast were increased by chemiluminescent light compared with visual inspection, but only the difference of lesion contrast was statistically significant. In 22.0% of patients, additional lesions were detected and 88.9% of them were diagnosed to have OLP histopathologically. 17.1% of patients noted discomfort and 9.8% of patients showed complications after chemiluminescent test. Conclusion: Chemiluminescent light may not be proper for the screen test of oral cancer or premalignant lesion but showed some possibility for additional diagnostic tool for definitively diagnosed patients in determination of lesion margin and scope.

Analysis and cause of occurrence of lining cracks on NATM tunnel based on the precise inspection for safety and diagnosis - Part I (정밀안전진단 결과를 활용한 NATM터널(무근)의 라이닝 균열 종류별 발생원인 및 분석 - Part I)

  • Choo, Jin-Ho;Park, Sung-Woo;Kim, Hyung-Tak;Jee, Kee-Hwan;Yoon, Tae-Gook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.199-214
    • /
    • 2011
  • A crack is the main cause to affect the integrity of tunnel lining as well as leakage, spalling, exposed rebar, corrosion, carbonation and so on. Since the 1980, NATM has prevailed on excavation method and geotechnical philosophy in tunnel. Although the pattern of cracks has been reported by several engineers' effort, it was only focused on longitudinal cracks of lining. Eleven operational NATM tunnels have been conducted with the precise inspection for safety and diagnosis by KISTEC (Korea Infrastructure Safety and Technology Incorporation). With those results, the crack patterns by the spatial distribution and appearance for each tunnel have been analyzed and the cause of occurrence for seven common types of cracks in NATM tunnels was classified. Additionally, the longitudinal crack on lining above duct slab was figured out by numerical simulation and field inspection. Each crack has been analyzed by CCD (Charge-Coupled Device) scanner image with 3D configuration. Each type of cracks is also explained with output of experimental and condition of construction. Defined cracks on NATM tunnels will be good example for periodical inspection and precise inspection for safety and diagnosis.

A Study on Performance Diagnosis of the Pulley Type Automatic Tensioning Device and Improvement of Maintenance (활차식 자동장력조정장치 성능진단 및 유지보수 개선에 관한 연구)

  • Park, Hyun;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1103-1107
    • /
    • 2016
  • The automatic tensioning device of the catenary system constantly maintains the tension of the trolley wire by absorbing the variations due to the elasticity of the line caused by temperature variation. The tension plays an important role in affecting the electric motorcar operation directly. This paper suggests the methodology of the life cycle extension and the maintenance of the automatic tensioning device by means of performance diagnosis of the pulley type automatic tensioning device which has been commonly used for the electric railway system. Through conducting performance diagnosis and comparative test for the wornout pulley type automatic tensioning device by replacing the components such as the bearing and the bearing shaft without replacing all the assembly, the tensioning device is analyzed whether it is properly functioned. Provided that the maintenance regulation is reinforced so as to implement the bearing replacement through periodical precise inspection along with random check-up inspection which is now carried out by the operating organizations, it is ensured that the life cycle extension and the reduction of maintenance cost of the tensioning device could be achieved.

A Development of Measuring Instrument of Portable Partial Discharge for Diagnosis of GIS Installation and Application (GIS 설비 진단을 위한 포터블 부분방전 측정장치 개발 및 응용)

  • Kim, Jong-Seo;Kim, Jin-Tea;Shin, Heung-Sik;Lee, Heung-Jea
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.231-234
    • /
    • 2009
  • Recently, to the development of a highly information-oriented society to a large increase in dependence on power, Accordingly, it is need that active development and spread of preservation technology on accident prevention in operation electrical equipment. However, to lack of the use on maintenance technology of power equipment and to increase of power usage is growing deterioration of power equipment, this is a cause on casualties, property damage and the occurrence of disasters is a growing. GIS equipments which are operated from domestic except the equipment which manages from the big business are depend on a most visual inspection, and do inspection method or measuring instrument etc. a condition which is not supplied widely. Currently, many to measure instrument used in domestic is very expensive or foreign, it will be able to substitute this, the development necessity of the diagnosis technique and the measuring instrument is demanded.

A Study on the Sasang Constitutional Checkup List and Inspection Diagnosis of Face and Tongue (사상체질진단표(四象體質診斷表) 및 망진(望診), 설진(舌診)에 관한 연구(硏究))

  • Kim, Jong-Che;Choi, Min-Ki;Jung, Woon-Ki;Shin, Woo-Young;Kim, Sun-Hyung;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.156-175
    • /
    • 2007
  • 1. Objectives and Methods This study was performed to know the relationship between Sasang Constitution and characteristics of ordinary symptoms, inspection diagnosis of face and tongue. There were 666 participants(280 men and 386 women) who answered Sasang Constitutional Checkup list and were taken pictures of faces and tongues. Sasang Constitution was diagnosed by only PSSC(Phonetic System for Sasang Constitution). Distribution of Sasang Constitution and X2 test, kappa value for agreement were calculated using SPSS 10.0. 2. Results From characteristics of ordinary symptoms' point of view, Taeeumin had loud voices, big body shapes and easily sweated themselves. They felt good after sweating and had warm hands and feet. And their upper back, shoulders and chest were, they thought, well developed. They were apt to have meals quickly and overeat themselves. Soyangin and Soeumin had thin body shapes and were difficult to sweat themselves and felt powerless after sweating. They had cold hands and feet. Especially, Soeumin was apt to have meals slowly and a little amounts. They walked so fast. Soyangin was introvert and had developed their abdomen and waist. 'Looking heavy and steady' was higher in Taeeumin, 'delicate and modest' was higher in Soeumin(42.8%) and Soyangin(36.1 %) in first impression. It was thought to be difficult to discriminate Soyangin from Soeumin in first impression and make a notion of right Soyangin's first impression. Soyangin had pinky tongue color and little tongue fur whereas Soeumin had red tongue color and whitish tongue fur. Taeeumin had whitish tongue fur too. 3. Conclusions To diagnose Sasang Constitution much effectively, PSSC results and comprehensive Sasang Constitutional Checkup list extracted from effective Questionnaire items and Face and Tongue Inspection Diagnosis are thought to be needed.

  • PDF

Tunnel Safety Diagnosis in Near-excavation by In-depth Inspection of Tunnel (기존터널 안전진단 결과를 통한 근접시공 시 터널 안정성 평가)

  • Kim, Seok-Jae;Kim, Min-Seok;Kim, Jun-Chul;Yoo, Young-Il;Oh, Joung-Bae;Oh, Sae-Joon
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.347-356
    • /
    • 2006
  • We analyzed case studies doing in-depth inspection of tunnel to maintain safety of existing tunnel in constructing new tunnel near to a existing tunnel with single track. Futhermore, We accomplished in-depth inspection of existing tunnel and numerical analysis. We suggested remedies to security safety of existing tunnel. We applied line drilling and pre-large hole boring method not to have an effect on existing tunnel and convinced the safety of existing tunnel from blast-vibration and blast-noise of numerical analysis. We planed to install basset system to measure displacement of existing tunnel according to excavating new tunnel.